/content/hbtbt/ae/en/search-results.html

Fire Alarm Control Panels

SFP-2402 Conventional Fire Alarm Control Panel

Notifier SFP-2402 and SFP-2402E Fire Alarm Control Panels (FACPs) bring the latest in microprocessor technology to conventional fire controls.

Notifier SFP-2402 and SFP-2402E Fire Alarm Control Panels (FACPs) bring the latest in microprocessor technology to conventional fire controls. The SFP-2402 is compatible with the i³™ smoke detectors from System Sensor with drift compensation, maintenance alert, and freeze warning. Automatic synchronization of audio/visual devices with three selections for manufacturer protocol. The Notification Appliance Circuit (NAC) protocol can silence audible devices while strobes continue to flash, using a single pair of wires.The SFP-2402 is compatible with conventional input devices such as two- and four-wire smoke detectors, pull stations, water flow devices, tamper switches and other normally-open contact devices. Refer to the Notifier Device Compatibility Document PN 15378 for a complete list of compatible devices.Activation of a compatible smoke detector or any normally-open fire alarm initiating device activates audible and visual signalling devices, illuminates an indicating LED, sounds the piezo sounder at the FACP, activates the FACP alarm relay and operates an optional module used to notify a remote station or initiate an auxiliary control function.Features & Benefits:
  • Two Style B (Class B) Initiating Device Circuits (IDCs)
  • One Style Y (Class B) NAC
  • i³™ Technology
  • NAC synchronization
  • Programmable NAC
  • Control buttons
  • LED indicators
  • Optional dress panel
Certifications:
  • UL Listed: S635
  • MEA: 297-01-E Vol. II
  • CSFM: 7165-0028: 220

Others

  • Maximum Battery Capacity
    • 18
  • Standby Current
    • 4 milliampere
  • Output Current
    • 15 ampere
  • For Use With
    • PN 15378
    • Backbox
    • Other Normally-Open Contact Devices
    • Tamper Switches
    • Two and Four Wire Smoke Detectors
    • Pull Stations
    • Water-Flow Devices
  • Loop Capacity
    • 2

Others

  • Maximum Battery Capacity
    • 18
  • Standby Current
    • 4 milliampere
  • Output Current
    • 15 ampere
  • For Use With
    • PN 15378
    • Backbox
    • Other Normally-Open Contact Devices
    • Tamper Switches
    • Two and Four Wire Smoke Detectors
    • Pull Stations
    • Water-Flow Devices
  • Loop Capacity
    • 2
  • For Use With : PN 15378|Backbox|Other Normally-Open Contact Devices|Tamper Switches|Two and Four Wire Smoke Detectors|Pull Stations|Water-Flow Devices
  • Loop Capacity : 2
  • Maximum Battery Capacity : 18
  • Standby Current : 4 milliampere
  • Output Current : 15 ampere
Others
Name
Description
File Size
Date
Size
NOTIFIER Seismic Certificate of Compliance
application/pdf 368.19 KB
6/15/2022
368.19 KB
Brochure
Name
Description
File Size
Date
Size
NOTIFIER Life Safety & Emergency Communications Systems Information Guide
application/pdf 2.68 MB
6/14/2022
2.68 MB
Data Sheet
Name
Description
File Size
Date
Size
SFP-2404(E) Data Sheet
application/pdf 169.75 KB
8/16/2022
169.75 KB
Name
Description
File Size
Date
Size
NOTIFIER Seismic Certificate of Compliance
368.19 KB
6/15/2022
368.19 KB
NOTIFIER Life Safety & Emergency Communications Systems Information Guide
2.68 MB
6/14/2022
2.68 MB
SFP-2404(E) Data Sheet
169.75 KB
8/16/2022
169.75 KB
Name
Description
File Size
Date
Size
NOTIFIER Seismic Certificate of Compliance
368.19 KB
6/15/2022
NOTIFIER Life Safety & Emergency Communications Systems Information Guide
2.68 MB
6/14/2022
SFP-2404(E) Data Sheet
169.75 KB
8/16/2022
Image
SKU
Description
alt
SFP-2402
2-Zone Fire Alarm Control Panel
alt
SFP-2402E
2-Zone Fire Alarm Control Panel Export
Image
SKU
Description
alt
SFP-2402
2-Zone Fire Alarm Control Panel
alt
SFP-2402E
2-Zone Fire Alarm Control Panel Export