Overview

The Notifier SFP-2404 and SFP-2404E Fire Alarm Control Panels (FACPs) bring the latest in microprocessor technology to conventional fire controls. The SFP-2404 is compatible with the smoke detectors from System Sensor, with drift compensation, maintenance alert, and freeze warning. Automatic synchronization of audio/visual devices with three selections for manufacturer protocol.

The Notification Appliance Circuit (NAC) protocol can silence audible devices while strobes continue to flash, using a single pair of wires. The SFP-2404 is compatible with conventional input devices such as two- and four-wire smoke detectors, pull stations, water flow devices, tamper switches and other normally-open contact devices.

Features & Benefits:
  • Four Style B (Class B) Initiating Device Circuits (IDCs)
  • Two Style Y (Class B) NACs
  • Optional module that converts all four IDCs and two NACs to Class A operation
  • Silent or audible Walk Test operation mode commanded from the front keypad, with automatic return-to-normal after one hour of inactivity
  • Each zone may be programmed for supervisory or fire
  • Each zone has separate red and yellow LEDs
  • Zone 4 is programmable for combination of tamper supervisory monitoring and water flow alarm
  • Form-C Alarm, Trouble, and Supervisory relays
Certifications:
  • UL Listed: S635
  • MEA: 297-01-E Vol. II
  • CSFM: 7165-0028:220
Specifications

Others

  • Standby Current
    • 4 milliampere
  • Maximum Battery Capacity
    • 18
  • Output Current
    • 15 ampere
  • For Use With
    • Pull Stations volt
    • Other Normally-Open Contact Devices volt
    • Backbox volt
    • Two and Four Wire Smoke Detectors volt
    • Tamper Switches volt
    • PN 15378 volt
    • Water-Flow Devices volt
  • Loop Capacity
    • 4 voltage direct current
    • 1 voltage direct current

Others

  • Standby Current
    • 4 milliampere
  • Maximum Battery Capacity
    • 18
  • Output Current
    • 15 ampere
  • For Use With
    • Pull Stations volt
    • Other Normally-Open Contact Devices volt
    • Backbox volt
    • Two and Four Wire Smoke Detectors volt
    • Tamper Switches volt
    • PN 15378 volt
    • Water-Flow Devices volt
  • Loop Capacity
    • 4 voltage direct current
    • 1 voltage direct current
  • For Use With : Pull Stations volt|Other Normally-Open Contact Devices volt|Backbox volt|Two and Four Wire Smoke Detectors volt|Tamper Switches volt|PN 15378 volt|Water-Flow Devices volt
  • Loop Capacity : 4 voltage direct current|1 voltage direct current
  • Standby Current : 4 milliampere
  • Maximum Battery Capacity : 18
  • Output Current : 15 ampere
Others
Name
Description
File Size
Date
Size
SFP-2404(E) Data Sheet
application/pdf 169.75 KB
12/9/2022
169.75 KB
NOTIFIER Seismic Certificate of Compliance
application/pdf 368.19 KB
1/2/2023
368.19 KB
Brochure
Name
Description
File Size
Date
Size
NOTIFIER Life Safety & Emergency Communications Systems Information Guide
application/pdf 2.68 MB
6/14/2022
2.68 MB
Name
Description
File Size
Date
Size
NOTIFIER Life Safety & Emergency Communications Systems Information Guide
2.68 MB
6/14/2022
2.68 MB
SFP-2404(E) Data Sheet
169.75 KB
12/9/2022
169.75 KB
NOTIFIER Seismic Certificate of Compliance
368.19 KB
1/2/2023
368.19 KB
Name
Description
File Size
Date
Size
SFP-2404(E) Data Sheet
169.75 KB
12/9/2022
NOTIFIER Seismic Certificate of Compliance
368.19 KB
1/2/2023
NOTIFIER Life Safety & Emergency Communications Systems Information Guide
2.68 MB
6/14/2022
Product Number
SKUs
Image
SKU
Description
alt
SFP-2404
4-Zone Fire Alarm Control Panel
alt
SFP-2404E
4-Zone Notifier Fire Alarm Control Panel Export
Image
SKU
Description
alt
SFP-2404
4-Zone Fire Alarm Control Panel
alt
SFP-2404E
4-Zone Notifier Fire Alarm Control Panel Export