Fire Alarm Control Panels
SFP-2404 Conventional Fire Alarm Control Panel
Notifier Fire Alarm Control Panel by Honeywell brings a range of fire alarm control panel with latest microprocessor technology to conventional fire controls.
The Notifier SFP-2404 and SFP-2404E Fire Alarm Control Panels (FACPs) bring the latest in microprocessor technology to conventional fire controls. The SFP-2404 is compatible with the smoke detectors from System Sensor, with drift compensation, maintenance alert, and freeze warning. Automatic synchronization of audio/visual devices with three selections for manufacturer protocol.
The Notification Appliance Circuit (NAC) protocol can silence audible devices while strobes continue to flash, using a single pair of wires. The SFP-2404 is compatible with conventional input devices such as two- and four-wire smoke detectors, pull stations, water flow devices, tamper switches and other normally-open contact devices.
Features & Benefits:- Four Style B (Class B) Initiating Device Circuits (IDCs)
- Two Style Y (Class B) NACs
- Optional module that converts all four IDCs and two NACs to Class A operation
- Silent or audible Walk Test operation mode commanded from the front keypad, with automatic return-to-normal after one hour of inactivity
- Each zone may be programmed for supervisory or fire
- Each zone has separate red and yellow LEDs
- Zone 4 is programmable for combination of tamper supervisory monitoring and water flow alarm
- Form-C Alarm, Trouble, and Supervisory relays
- UL Listed: S635
- MEA: 297-01-E Vol. II
- CSFM: 7165-0028:220
Others
- Standby Current
- 4 milliampere
- Maximum Battery Capacity
- 18
- Output Current
- 15 ampere
- For Use With
- Pull Stations volt
- Other Normally-Open Contact Devices volt
- Backbox volt
- Two and Four Wire Smoke Detectors volt
- Tamper Switches volt
- PN 15378 volt
- Water-Flow Devices volt
- Loop Capacity
- 4 voltage direct current
- 1 voltage direct current
Others
- Standby Current
- 4 milliampere
- Maximum Battery Capacity
- 18
- Output Current
- 15 ampere
- For Use With
- Pull Stations volt
- Other Normally-Open Contact Devices volt
- Backbox volt
- Two and Four Wire Smoke Detectors volt
- Tamper Switches volt
- PN 15378 volt
- Water-Flow Devices volt
- Loop Capacity
- 4 voltage direct current
- 1 voltage direct current
- For Use With : Pull Stations volt|Other Normally-Open Contact Devices volt|Backbox volt|Two and Four Wire Smoke Detectors volt|Tamper Switches volt|PN 15378 volt|Water-Flow Devices volt
- Loop Capacity : 4 voltage direct current|1 voltage direct current
- Standby Current : 4 milliampere
- Maximum Battery Capacity : 18
- Output Current : 15 ampere