Fire Alarm Control Panels
SFP-5UD Conventional Fire Alarm Control Panel
Five zone fire alarm control panels provide reliable fire signaling protection for small to medium-sized commercial, industrial, and institutional buildings.
Five zone fire alarm control panels provide reliable fire signaling protection for small to medium-sized commercial, industrial, and institutional buildings. Both panels include built-in communicators for Central Station Service and remote upload/download. These FACPs are compatible with system sensor’s microprocessor-based i3 series detectors. These conventional smoke detectors can transmit a maintenance trouble signal to the FACP indicating the need for cleaning and a supervisory “freeze” signal when the ambient temperature falls below the detector rating. Additionally, five zone fire alarm control panels compatible with conventional input devices such as two- and four-wire smoke detectors, pull stations, waterflow devices, tamper switches, and other normally-open contact devices. Outputs include four NACs (Notification Appliance Circuits), three programmable form-C relays (factory programmed for alarm, trouble, and supervisory) and 24 VDC special application resettable and nonresettable power outputs. The FACPs supervise all wiring, AC voltage, battery level and telephone line integrity. Activation of a compatible smoke detector or any normally-open fire alarm initiating device will activate audible and visual signaling devices, illuminate an indicating LED, sound the piezo sounder at the FACP, activate the communicator and FACP alarm relay, and operate an optional module used to notify a remote station or initiate an auxiliary control function.
Features & Benefits:- Built-in DACT (Digital Alarm Communicator/Transmitter)
- Form-C Relays for Alarm, Trouble and Supervisory
- Low AC voltage sense
- Alarm Verification
- PAS (Positive Alarm Sequence)
- Automatic battery trickle charger
- UL listed
- FM approved
- CSFM: 7165-0028:0246
Others
- Minimum Operating Humidity
- 2 Percentage
- Output Current
- 15 milliampere
- Standby Current
- 2 milliampere
- Maximum Battery Capacity
- 18
- Application
- Industrial
- Commercial
- Institutional Buildings
- Main Frequency
- 50/60 hertz
- For Use With
- Backbox volt
- Networkable or Standalone
- Networkable
- Communication Protocols
- PSDN voltage alternating current
- Remote Station System voltage alternating current
- IPDACT-2/2UD Internet Monitoring Module voltage alternating current
- Local System voltage alternating current
- IPDACT voltage alternating current
- Central Station voltage alternating current
- OT voltage alternating current
Others
- Minimum Operating Humidity
- 2 Percentage
- Output Current
- 15 milliampere
- Standby Current
- 2 milliampere
- Maximum Battery Capacity
- 18
- Application
- Industrial
- Commercial
- Institutional Buildings
- Main Frequency
- 50/60 hertz
- For Use With
- Backbox volt
- Networkable or Standalone
- Networkable
- Communication Protocols
- PSDN voltage alternating current
- Remote Station System voltage alternating current
- IPDACT-2/2UD Internet Monitoring Module voltage alternating current
- Local System voltage alternating current
- IPDACT voltage alternating current
- Central Station voltage alternating current
- OT voltage alternating current
- Application : Industrial|Commercial|Institutional Buildings
- Main Frequency : 50/60 hertz
- For Use With : Backbox volt
- Networkable or Standalone : Networkable
- Communication Protocols : PSDN voltage alternating current|Remote Station System voltage alternating current|IPDACT-2/2UD Internet Monitoring Module voltage alternating current|Local System voltage alternating current|IPDACT voltage alternating current|Central Station voltage alternating current|OT voltage alternating current
- Minimum Operating Humidity : 2 Percentage
- Output Current : 15 milliampere
- Standby Current : 2 milliampere
- Maximum Battery Capacity : 18