/content/hbtbt/ae/en/search-results.html

Fire Alarm Control Panels

SFP-5UD Conventional Fire Alarm Control Panel

Five zone fire alarm control panels provide reliable fire signaling protection for small to medium-sized commercial, industrial, and institutional buildings.

Five zone fire alarm control panels provide reliable fire signaling protection for small to medium-sized commercial, industrial, and institutional buildings. Both panels include built-in communicators for Central Station Service and remote upload/download. These FACPs are compatible with system sensor’s microprocessor-based i3 series detectors. These conventional smoke detectors can transmit a maintenance trouble signal to the FACP indicating the need for cleaning and a supervisory “freeze” signal when the ambient temperature falls below the detector rating. Additionally, five zone fire alarm control panels compatible with conventional input devices such as two- and four-wire smoke detectors, pull stations, waterflow devices, tamper switches, and other normally-open contact devices. Outputs include four NACs (Notification Appliance Circuits), three programmable form-C relays (factory programmed for alarm, trouble, and supervisory) and 24 VDC special application resettable and nonresettable power outputs. The FACPs supervise all wiring, AC voltage, battery level and telephone line integrity. Activation of a compatible smoke detector or any normally-open fire alarm initiating device will activate audible and visual signaling devices, illuminate an indicating LED, sound the piezo sounder at the FACP, activate the communicator and FACP alarm relay, and operate an optional module used to notify a remote station or initiate an auxiliary control function.

Features & Benefits:
  • Built-in DACT (Digital Alarm Communicator/Transmitter)
  • Form-C Relays for Alarm, Trouble and Supervisory
  • Low AC voltage sense
  • Alarm Verification
  • PAS (Positive Alarm Sequence)
  • Automatic battery trickle charger
Certifications:
  • UL listed
  • FM approved
  • CSFM: 7165-0028:0246

Others

  • Minimum Operating Humidity
    • 2 Percentage
  • Output Current
    • 15 milliampere
  • Standby Current
    • 2 milliampere
  • Maximum Battery Capacity
    • 18
  • Application
    • Industrial
    • Commercial
    • Institutional Buildings
  • Main Frequency
    • 50/60hertz
  • For Use With
    • Backbox
  • Networkable or Standalone
    • Networkable
  • Communication Protocols
    • PSDN
    • Remote Station System
    • IPDACT-2/2UD Internet Monitoring Module
    • Local System
    • IPDACT
    • Central Station
    • OT

Others

  • Minimum Operating Humidity
    • 2 Percentage
  • Output Current
    • 15 milliampere
  • Standby Current
    • 2 milliampere
  • Maximum Battery Capacity
    • 18
  • Application
    • Industrial
    • Commercial
    • Institutional Buildings
  • Main Frequency
    • 50/60hertz
  • For Use With
    • Backbox
  • Networkable or Standalone
    • Networkable
  • Communication Protocols
    • PSDN
    • Remote Station System
    • IPDACT-2/2UD Internet Monitoring Module
    • Local System
    • IPDACT
    • Central Station
    • OT
  • Application : Industrial|Commercial|Institutional Buildings
  • Main Frequency : 50/60hertz
  • For Use With : Backbox
  • Networkable or Standalone : Networkable
  • Communication Protocols : PSDN|Remote Station System|IPDACT-2/2UD Internet Monitoring Module|Local System|IPDACT|Central Station|OT
  • Minimum Operating Humidity : 2 Percentage
  • Output Current : 15 milliampere
  • Standby Current : 2 milliampere
  • Maximum Battery Capacity : 18
Others
Name
Description
File Size
Date
Size
NOTIFIER Seismic Certificate of Compliance
application/pdf 368.19 KB
6/15/2022
368.19 KB
SFP-5UD-SFP-10UD Conventional Control Panel Engineering Specification
application/msword 159.5 KB
6/20/2022
159.5 KB
Brochure
Name
Description
File Size
Date
Size
NOTIFIER Life Safety & Emergency Communications Systems Information Guide
application/pdf 2.68 MB
6/14/2022
2.68 MB
Conventional Fire Alarm Control Panel Solutions Brochure
application/pdf 1.32 MB
6/20/2022
1.32 MB
Data Sheet
Name
Description
File Size
Date
Size
SFP-5UDC-SFP-10UDC Data Sheet
application/pdf 167.45 KB
8/16/2022
167.45 KB
Name
Description
File Size
Date
Size
NOTIFIER Seismic Certificate of Compliance
368.19 KB
6/15/2022
368.19 KB
NOTIFIER Life Safety & Emergency Communications Systems Information Guide
2.68 MB
6/14/2022
2.68 MB
SFP-5UD-SFP-10UD Conventional Control Panel Engineering Specification
159.5 KB
6/20/2022
159.5 KB
Conventional Fire Alarm Control Panel Solutions Brochure
1.32 MB
6/20/2022
1.32 MB
SFP-5UDC-SFP-10UDC Data Sheet
167.45 KB
8/16/2022
167.45 KB
Name
Description
File Size
Date
Size
NOTIFIER Seismic Certificate of Compliance
368.19 KB
6/15/2022
SFP-5UD-SFP-10UD Conventional Control Panel Engineering Specification
159.5 KB
6/20/2022
NOTIFIER Life Safety & Emergency Communications Systems Information Guide
2.68 MB
6/14/2022
Conventional Fire Alarm Control Panel Solutions Brochure
1.32 MB
6/20/2022
SFP-5UDC-SFP-10UDC Data Sheet
167.45 KB
8/16/2022
Image
SKU
Description
alt
SFP-5UD
Fire Alarm Control Panel 5 Zone Conventional
alt
SFP-5UDC
Fire Alarm Control Panel 5 Zone Conventional Canada
alt
SFP-5UDE
Fire Alarm Control Panel 5 Zone Conventional Export
alt
SFP-5UDR
Fire Alarm Control Panel 5 Zone Conventional Red
Image
SKU
Description
alt
SFP-5UD
Fire Alarm Control Panel 5 Zone Conventional
alt
SFP-5UDC
Fire Alarm Control Panel 5 Zone Conventional Canada
alt
SFP-5UDE
Fire Alarm Control Panel 5 Zone Conventional Export
alt
SFP-5UDR
Fire Alarm Control Panel 5 Zone Conventional Red