/content/hbtbt/ca/en/search-results.html

    Gas Detectors

    4 Series

    City Tech’s 4-Series gas sensors are the industry standard for portable gas detectors. The range includes sensors which detect oxygen and toxic gases, carbon dioxide and hydrocarbons and fully certified pellistors for combustible gas detection

    Overview
    Honeywell 4-Series gas sensors are the industry standard for use in portable gas detectors. The range includes sensors which detect oxygen, ammonia, hydrogen sulfide, carbon monoxide, chlorine, nitric oxide, and numerous toxic and fully certified pellistors for combustible gas detection.

    The 4 Series features a large, robust sensor design and is durable to withstand environmental demands. In addition to portable devices, the comprehensive range of sensors is suitable for fixed safety and emissions applications.

    Introducing the 4NH3LL-100
    • The Honeywell 4NH3LL-100 is a 3-electrode electrochemical sensor designed to detect ammonia (NH3) levels ranging from 0 ppm to 100 ppm.
    • This long-life sensor is suitable for both portable and fixed gas detection in diverse applications, including farming, refrigeration systems, and various industrial sectors such as food, semiconductor, and chemical industries.
    • Sensor can operate constantly with background levels of ammonia without affecting the sensor’s performance - ideal for livestock and poultry farming applications.
    • The sensor operates effectively within a temperature range of -20°C to 40°C and a humidity level from 15% to 90% RH. (Could be operated intermittently from -40°C to 50°C)
    • It has a lifespan of two years in fresh air and is backed by a 12-month warranty from the date of shipment.
    • The sensor exhibits a sensitivity of 30 nA/ppm (±20 nA/ppm) and a response time of less than 90 seconds. 
    Specifications

    Applications & Compatibility

    • Application
      • Drainage and Sewage Areas
      • Fire Detection
      • Food Processing
      • Leakage Detection
      • Manufacturing Factories
      • Mining Processes
      • Portable & Fixed Life Safety
      • Refineries
      • Residential
      • TVL Monitoring (Threshold Value Level)
      • Ventilation Control
    • Recommended Load Resistor
      • 10 Ohm
      • 33 Ohm
      • 5 Ohm

    Overview

    • Warranty
      • 12 Months from Date of Dispatch
      • 18 Months from Date of Dispatch
    • Brand
      • Honeywell
      • Honeywell Citytech

    Operating Characteristics

    • Storage Temperature
      • 0 to 20°C
      • 10 to 30°C

    Standards & Certifications

    • Standards & Certifications
      • AQ6205-2006
      • ATEX
      • EN 45544-2000
      • EN/IEC 60079-0
      • RoHS Compliant
      • UL Certified - UL2075
      • UL and CSA

    Features

    • Series Name
      • 4
      • 4CFC
      • 4CM
      • CiTiceL 4
    • Operating Principle
      • 2-Electrode Electrochemical
      • 3-Electrode Electrochemical
      • 4-Electrode Electrochemical
      • Catalytic Oxidation
    • Features & Benefits
      • Anti-Poisoning in the Environment with Acrylonitrile Background
      • Compact Size
      • Designed for Breath Analysis
      • Enhanced Long-Term Stability
      • Extended Operating Range
      • Factory Calibrated MV Output
      • Fast Response and Recovery Time
      • High Sensitivity for Better Resolution
      • Higher Durability and Stability
      • Ideal for Portable Life Safety Applications
      • Improved Performance Variability
      • Industry Leading Reliability
      • Long Life
      • Low Cros Sensitivity To Hydrogen
      • Low Long-Term Output Drift
      • Low Temperature and Humidity Effect
      • On-Board Hydrogen and Temperature Compensation
      • Robust 3-Series Packaging
      • Stable Performance Six Sigma Output Performance

    Electrical Specifications

    • Maximum s/c Current
      • < 1.0 A

    Technical Specifications

    • Gases Detected
      • Acrylonitrile
      • Carbon Monoxide (CO)
      • Chlorine (CL)
      • Ethylene Oxide (C2H4O)
      • Hydrogen (H)
      • Hydrogen Cyanide (HCN)
      • Hydrogen Sulfide (H2S)
      • Most Combustible Gases and Vapours
      • Nitric Oxide (NO)
      • Nitrogen Dioxide (NO2)
      • Sulfur Dioxide (SO2)
    • Calibration
      • via Built-in Span and Zero Potentiometer
    • Auxiliary Electrode
      • To Compensate for Maximum 2,000 ppm H2 Cross Interference

    Others

    • Industry
      • Aerospace
      • Energy

    Applications & Compatibility

    • Application
      • Drainage and Sewage Areas
      • Fire Detection
      • Food Processing
      • Leakage Detection
      • Manufacturing Factories
      • Mining Processes
      • Portable & Fixed Life Safety
      • Refineries
      • Residential
      • TVL Monitoring (Threshold Value Level)
      • Ventilation Control
    • Recommended Load Resistor
      • 10 Ohm
      • 33 Ohm
      • 5 Ohm

    Overview

    • Warranty
      • 12 Months from Date of Dispatch
      • 18 Months from Date of Dispatch
    • Brand
      • Honeywell
      • Honeywell Citytech

    Operating Characteristics

    • Storage Temperature
      • 0 to 20°C
      • 10 to 30°C

    Standards & Certifications

    • Standards & Certifications
      • AQ6205-2006
      • ATEX
      • EN 45544-2000
      • EN/IEC 60079-0
      • RoHS Compliant
      • UL Certified - UL2075
      • UL and CSA

    Features

    • Series Name
      • 4
      • 4CFC
      • 4CM
      • CiTiceL 4
    • Operating Principle
      • 2-Electrode Electrochemical
      • 3-Electrode Electrochemical
      • 4-Electrode Electrochemical
      • Catalytic Oxidation
    • Features & Benefits
      • Anti-Poisoning in the Environment with Acrylonitrile Background
      • Compact Size
      • Designed for Breath Analysis
      • Enhanced Long-Term Stability
      • Extended Operating Range
      • Factory Calibrated MV Output
      • Fast Response and Recovery Time
      • High Sensitivity for Better Resolution
      • Higher Durability and Stability
      • Ideal for Portable Life Safety Applications
      • Improved Performance Variability
      • Industry Leading Reliability
      • Long Life
      • Low Cros Sensitivity To Hydrogen
      • Low Long-Term Output Drift
      • Low Temperature and Humidity Effect
      • On-Board Hydrogen and Temperature Compensation
      • Robust 3-Series Packaging
      • Stable Performance Six Sigma Output Performance

    Electrical Specifications

    • Maximum s/c Current
      • < 1.0 A

    Technical Specifications

    • Gases Detected
      • Acrylonitrile
      • Carbon Monoxide (CO)
      • Chlorine (CL)
      • Ethylene Oxide (C2H4O)
      • Hydrogen (H)
      • Hydrogen Cyanide (HCN)
      • Hydrogen Sulfide (H2S)
      • Most Combustible Gases and Vapours
      • Nitric Oxide (NO)
      • Nitrogen Dioxide (NO2)
      • Sulfur Dioxide (SO2)
    • Calibration
      • via Built-in Span and Zero Potentiometer
    • Auxiliary Electrode
      • To Compensate for Maximum 2,000 ppm H2 Cross Interference

    Others

    • Industry
      • Aerospace
      • Energy
    • Application : Drainage and Sewage Areas|Fire Detection|Food Processing|Leakage Detection|Manufacturing Factories|Mining Processes|Portable & Fixed Life Safety|Refineries|Residential|TVL Monitoring (Threshold Value Level)|Ventilation Control
    • Warranty : 12 Months from Date of Dispatch|18 Months from Date of Dispatch
    • Storage Temperature : 0 to 20°C|10 to 30°C
    • Standards & Certifications : AQ6205-2006|ATEX|EN 45544-2000|EN/IEC 60079-0|RoHS Compliant|UL Certified - UL2075|UL and CSA
    • Series Name : 4|4CFC|4CM|CiTiceL 4
    • Recommended Load Resistor : 10 Ohm|33 Ohm|5 Ohm
    • Operating Principle : 2-Electrode Electrochemical|3-Electrode Electrochemical|4-Electrode Electrochemical|Catalytic Oxidation
    • Maximum s/c Current : < 1.0 A
    • Industry : Aerospace|Energy
    • Gases Detected : Acrylonitrile|Carbon Monoxide (CO)|Chlorine (CL)|Ethylene Oxide (C2H4O)|Hydrogen (H)|Hydrogen Cyanide (HCN)|Hydrogen Sulfide (H2S)|Most Combustible Gases and Vapours|Nitric Oxide (NO)|Nitrogen Dioxide (NO2)|Sulfur Dioxide (SO2)
    • Features & Benefits : Anti-Poisoning in the Environment with Acrylonitrile Background|Compact Size|Designed for Breath Analysis|Enhanced Long-Term Stability|Extended Operating Range|Factory Calibrated MV Output|Fast Response and Recovery Time|High Sensitivity for Better Resolution|Higher Durability and Stability|Ideal for Portable Life Safety Applications|Improved Performance Variability|Industry Leading Reliability|Long Life|Low Cros Sensitivity To Hydrogen|Low Long-Term Output Drift|Low Temperature and Humidity Effect|On-Board Hydrogen and Temperature Compensation|Robust 3-Series Packaging|Stable Performance Six Sigma Output Performance
    • Calibration : via Built-in Span and Zero Potentiometer
    • Brand : Honeywell|Honeywell Citytech
    • Auxiliary Electrode : To Compensate for Maximum 2,000 ppm H2 Cross Interference
    Name
    Date
    Size
    No Resources documents tagged to this product
    An error occurred . Please try after sometime

    _blank

    Filters

    Product Number
    Part Number
    Description
    Leaf Category
    Thumbnail
    Add to list
    15PA148-CX
    ENCLOSED BASIC - SPARE PART
    15PA148-CX
    ENCLOSED BASIC - SPARE PART
    15PA500-CX
    ENCLOSED SWITCH PART-ADAPTER PLATE
    15PA500-CX
    ENCLOSED SWITCH PART-ADAPTER PLATE
    15PA85-EX
    UNSEALED OI-PB SWITCH - SPARE PART
    15PA85-EX
    UNSEALED OI-PB SWITCH - SPARE PART
    19546-L5
    4AN SUB ASSEMBLY
    19546-L5
    4AN SUB ASSEMBLY
    2112B2003
    SURECELL CO(M)
    2112B2003
    SURECELL CO(M)
    2112B2003R
    Carbon Monoxide CO 4-series Replacement Sensor CO(M) (0-1000ppm) Surecell
    2112B2003R
    Carbon Monoxide CO 4-series Replacement Sensor CO(M) (0-1000ppm) Surecell
    2112B2004
    SURECELL CO(H)
    2112B2004
    SURECELL CO(H)
    2112B2005R
    4CF+ CO SENSOR IN POT
    2112B2005R
    4CF+ CO SENSOR IN POT
    2112B2006
    Carbon Monoxide CO 4-series Sensor 4CFC (0-1000ppm) CiTiceL
    2112B2006
    Carbon Monoxide CO 4-series Sensor 4CFC (0-1000ppm) CiTiceL
    2112B2006R
    CO 4CFC 1,000PPM 4SERIES SENSOR REP.
    2112B2006R
    CO 4CFC 1,000PPM 4SERIES SENSOR REP.