    Detector Test Equipment

    Vertex™ M Toxic Gas Monitoring System

    Multipoint Vertex™ M Toxic Gas Monitoring System using chemcassette technology with a maximum of 24 points

    Overview
    Vertex M helps facilities effectively safeguard against downtime by combining the most advanced Chemcassette® optics technologies and built-in system redundancies. Vertex M is a flexible, easy-to-use and reliable gas monitoring system. As your monitoring needs change, Vertex M expands its offering to as little as eight points and up to 24 points of continuous gas detection.
    The Vertex system can accept sampling points up to 400 feet (120 meters) from the central unit. Vertex M can also accept a mix of universal analyzer modules and pyrolyzer analyzers. The system monitors a wide variety of gases present in semiconductor fabrication with sensitivity as low as parts per billion (ppb).
    Even the best products deserve expert maintenance!

    Elevate your gas detectors’ potential with Honeywell's expert maintenance services! Maximize uptime, eliminate costs, and ensure on-time, on-budget project completion.

    Explore our fixed, portable, and high-tech support services now!

    Specifications

    Brand

    • Brand
      • Honeywell

    Features

    • Alarm Type
      • Capable of A1 and A2 Alarms per Point, per Point Maintenance/Instrument Faults, as well as General Analyzer A1, General Analyzer A2, and General Analyzer Instrument/Maintenance Faults
    • Visual Indicators
      • 1024 x 768 pixel Touch Screen with at-a-Glance System Status
    • Features & Benefits
      • 8 to 24 Point Toxic Gas Monitor Configurable for Use with up to 3 Universal Chemcassette Analyzers or Combination 1 Pyrolyzer Analyzer/1 Universal Chemcassette Analyzer
    • Display Type
      • 1024 x 768 pixel Touch Screen with at-a-Glance System Status

    Dimensions & Weight

    • Size
      • H: 56 in D: 36 in W: 24 in
    • Sampling Distance
      • Up to 400ft
    • Exhaust Length
      • 50 ft

    Technical Specifications

    • Sample Lines
      • ID: 0.156 in OD: 1/4 in FEP Teflon
      • ID: 0.190 in OD: 1/4 in FEP Teflon
    • Relays
      • Isolated (08X) or Non-Isolated (016X)
      • PLC: 32 Relays for 8 Channel Isolated Relay Option; 64 Relays Total for 16 Channel Non-Isolated Relay Option
    • Operating Altitude
      • -1,000 ft to 6,000 ft Above Sea Level
    • Network Interface
      • OLE for Process Control (OPC) Interface
    • Exhaust Line
      • ID: 3/8 in OD: 1/2 in Polypropylene
    • Digital Communication Ports
      • ControlNet
      • DF1
      • DeviceNet
      • Ethernet/CIP
      • LonWorks
      • ModBus Plus
      • Modbus/TCP
      • Profibus - DP
    • Analog Outputs
      • 4 to 20 mA (24 Channels)

    Electrical Specifications

    • Power Requirement
      • 110/230 V AC
    • Operating Voltage
      • 110 or 230 V AC ± 10% (Under Load) @50/60 Hz; 15A

    Operating Characteristics

    • Operating Humidity
      • 20 to 65% RH

    Applications & Compatibility

    • For Use With
      • Universal Chemcassette Analyzers and Pyrolyzer Analyzer

    Standards & Certifications

    • Certificates and Standards
      • CE Certified
      • EN 300 330-1 V1.8.1
      • EN 301 489-1 V1.9.2
      • EN 50270:2015
      • EN 61010-1:2010
      • EN IEC 63000:2018
      • EN ISO/IEC 17050-1:2010
      • RoHS

    Others

    • Industry
      • Manufacturing

    Brand

    • Brand
      • Honeywell

    Features

    • Alarm Type
      • Capable of A1 and A2 Alarms per Point, per Point Maintenance/Instrument Faults, as well as General Analyzer A1, General Analyzer A2, and General Analyzer Instrument/Maintenance Faults
    • Visual Indicators
      • 1024 x 768 pixel Touch Screen with at-a-Glance System Status
    • Features & Benefits
      • 8 to 24 Point Toxic Gas Monitor Configurable for Use with up to 3 Universal Chemcassette Analyzers or Combination 1 Pyrolyzer Analyzer/1 Universal Chemcassette Analyzer
    • Display Type
      • 1024 x 768 pixel Touch Screen with at-a-Glance System Status

    Dimensions & Weight

    • Size
      • H: 56 in D: 36 in W: 24 in
    • Sampling Distance
      • Up to 400ft
    • Exhaust Length
      • 50 ft

    Technical Specifications

    • Sample Lines
      • ID: 0.156 in OD: 1/4 in FEP Teflon
      • ID: 0.190 in OD: 1/4 in FEP Teflon
    • Relays
      • Isolated (08X) or Non-Isolated (016X)
      • PLC: 32 Relays for 8 Channel Isolated Relay Option; 64 Relays Total for 16 Channel Non-Isolated Relay Option
    • Operating Altitude
      • -1,000 ft to 6,000 ft Above Sea Level
    • Network Interface
      • OLE for Process Control (OPC) Interface
    • Exhaust Line
      • ID: 3/8 in OD: 1/2 in Polypropylene
    • Digital Communication Ports
      • ControlNet
      • DF1
      • DeviceNet
      • Ethernet/CIP
      • LonWorks
      • ModBus Plus
      • Modbus/TCP
      • Profibus - DP
    • Analog Outputs
      • 4 to 20 mA (24 Channels)

    Electrical Specifications

    • Power Requirement
      • 110/230 V AC
    • Operating Voltage
      • 110 or 230 V AC ± 10% (Under Load) @50/60 Hz; 15A

    Operating Characteristics

    • Operating Humidity
      • 20 to 65% RH

    Applications & Compatibility

    • For Use With
      • Universal Chemcassette Analyzers and Pyrolyzer Analyzer

    Standards & Certifications

    • Certificates and Standards
      • CE Certified
      • EN 300 330-1 V1.8.1
      • EN 301 489-1 V1.9.2
      • EN 50270:2015
      • EN 61010-1:2010
      • EN IEC 63000:2018
      • EN ISO/IEC 17050-1:2010
      • RoHS

    Others

    • Industry
      • Manufacturing
    • Brand : Honeywell
    • Alarm Type : Capable of A1 and A2 Alarms per Point, per Point Maintenance/Instrument Faults, as well as General Analyzer A1, General Analyzer A2, and General Analyzer Instrument/Maintenance Faults
    • Visual Indicators : 1024 x 768 pixel Touch Screen with at-a-Glance System Status
    • Size : H: 56 in D: 36 in W: 24 in
    • Sampling Distance : Up to 400ft
    • Sample Lines : ID: 0.156 in OD: 1/4 in FEP Teflon|ID: 0.190 in OD: 1/4 in FEP Teflon
    • Relays : Isolated (08X) or Non-Isolated (016X)|PLC: 32 Relays for 8 Channel Isolated Relay Option; 64 Relays Total for 16 Channel Non-Isolated Relay Option
    • Power Requirement : 110/230 V AC
    • Operating Voltage : 110 or 230 V AC ± 10% (Under Load) @50/60 Hz; 15A
    • Operating Humidity : 20 to 65% RH
    • Operating Altitude : -1,000 ft to 6,000 ft Above Sea Level
    • Network Interface : OLE for Process Control (OPC) Interface
    • Industry : Manufacturing
    • For Use With : Universal Chemcassette Analyzers and Pyrolyzer Analyzer
    • Features & Benefits : 8 to 24 Point Toxic Gas Monitor Configurable for Use with up to 3 Universal Chemcassette Analyzers or Combination 1 Pyrolyzer Analyzer/1 Universal Chemcassette Analyzer
    • Exhaust Line : ID: 3/8 in OD: 1/2 in Polypropylene
    • Exhaust Length : 50 ft
    • Display Type : 1024 x 768 pixel Touch Screen with at-a-Glance System Status
    • Digital Communication Ports : ControlNet|DF1|DeviceNet|Ethernet/CIP|LonWorks|ModBus Plus|Modbus/TCP|Profibus - DP
    • Certificates and Standards : CE Certified|EN 300 330-1 V1.8.1|EN 301 489-1 V1.9.2|EN 50270:2015|EN 61010-1:2010|EN IEC 63000:2018|EN ISO/IEC 17050-1:2010|RoHS
    • Analog Outputs : 4 to 20 mA (24 Channels)
    Name
    Date
    Size
    No Resources documents tagged to this product
    An error occurred . Please try after sometime

    _blank

    Filters

    Product Number
    Part Number
    Description
    Leaf Category
    Thumbnail
    Add to list
    1283K1090
    Sample Line Tubing Duct Adapter: Midas Gas Detector Accessories
    1283K1090
    Sample Line Tubing Duct Adapter: Midas Gas Detector Accessories
    1290-0066
    110 VAC Vertex M Base Rack
    1290-0066
    110 VAC Vertex M Base Rack
    1290-0071
    220 VAC Vertex M Base Rack
    1290-0071
    220 VAC Vertex M Base Rack
    1290-0072
    Vertex M™ with one (1) Universal Chemcassette Analyzer: This configuration contains a Vertex M™ Base Rack (110 VAC) with one (1) universal chemcassette analyzer, the data acquisition center, redundant pumps and power supplies, touch screen keyboard.
    1290-0072
    Vertex M™ with one (1) Universal Chemcassette Analyzer: This configuration contains a Vertex M™ Base Rack (110 VAC) with one (1) universal chemcassette analyzer, the data acquisition center, redundant pumps and power supplies, touch screen keyboard.
    1290-0073
    Vertex M™ with one (1) Pyrolyzer Analyzer: This configuration contains a Vertex M™ Base Rack (110 VAC) with one (1) pyrolyzer analyzer, the data acquisition center, redundant pumps and power supplies, touch screen keyboard.
    1290-0073
    Vertex M™ with one (1) Pyrolyzer Analyzer: This configuration contains a Vertex M™ Base Rack (110 VAC) with one (1) pyrolyzer analyzer, the data acquisition center, redundant pumps and power supplies, touch screen keyboard.
    1290-0074
    Vertex M™ with one (1) Universal Chemcassette Analyzer: This configuration contains a Vertex M™ Base Rack (220 VAC) with one (1) universal chemcassette analyzer, the data acquisition center, redundant pumps and power supplies, touch screen keyboard.
    1290-0074
    Vertex M™ with one (1) Universal Chemcassette Analyzer: This configuration contains a Vertex M™ Base Rack (220 VAC) with one (1) universal chemcassette analyzer, the data acquisition center, redundant pumps and power supplies, touch screen keyboard.
    1290-0075
    Vertex M™ with one (1) Pyrolyzer Analyzer: This configuration contains a Vertex M™ Base Rack (220 VAC) with one (1) pyrolyzer analyzer, the data acquisition center, redundant pumps and power supplies, touch screen keyboard.
    1290-0075
    Vertex M™ with one (1) Pyrolyzer Analyzer: This configuration contains a Vertex M™ Base Rack (220 VAC) with one (1) pyrolyzer analyzer, the data acquisition center, redundant pumps and power supplies, touch screen keyboard.
    1290-0076
    16 Channel Non-Isolated Relay OptionTotal of sixty-four (64) factory installed and field programmable Form A relays. Within each group of eight relays one side connected to a common terminal.
    1290-0076
    16 Channel Non-Isolated Relay OptionTotal of sixty-four (64) factory installed and field programmable Form A relays. Within each group of eight relays one side connected to a common terminal.
    1290-0077
    8 Channel Isolated Relay OptionTotal of thirty-two (32) factory installed and field programmable Form A relays. Each contact totally isolated.
    1290-0077
    8 Channel Isolated Relay OptionTotal of thirty-two (32) factory installed and field programmable Form A relays. Each contact totally isolated.
    1290-0078
    4-20 mA Interface
    1290-0078
    4-20 mA Interface