/content/hbtbt/de/de/search-results.html
    Diese Seite wird am Samstag, den 8. August, von 19:00 bis 05:00 Uhr EST (23:00 bis 09:00 Uhr GMT, Sonntag, den 9. August, von 01:00 bis 11:00 Uhr CET und von 04:30 bis 14:30 Uhr IST) wegen geplanter Wartungsarbeiten nicht erreichbar sein. Wir danken Ihnen für Ihre Geduld während dieser Zeit.

    Druckschalter und Sensoren

    DP2-12 Low Differential Pressure Transmitter

    The A/DP2 series is a line of low differential pressure transmitters that are capable of sensing full scale ranges down to 0.1” of water column. A/DP2 pressure transmitter utilizes a high-quality ceramic capacitive sensor.

    Übersicht

    The A/DP2 series is a line of low differential pressure transmitters that are capable of sensing full scale ranges down to 0.1” of water column. A/DP2 pressure transmitter utilizes a high-quality ceramic capacitive sensor to provide long-term stability and performance.

    Accuracy is +/- 0.3% of full scale over the compensated temperature range for most ranges. This is critical for optimizing building pressure. In addition to the requested span most units are capable of being field adjusted to a maximum of three additional spans by resetting the internal jumpers. This series also offers the option of a preassembled pitot tube for ease of installation.

    Features & Benefits:
    • The A/DP2 Series is covered by ACI's Five (5) Year Limited Warranty
    • Utilizes a high-quality ceramic capacitive sensor
    • Provide long-term stability and performance
    • RoHS compliant
    Certifications:
    • RoHS compliant
    Spezifikationen

    Andere

    • Minimum Operating Ambient Temperature
      • -10 degree Celsius
      • 14 degree Fahrenheit
    • Maximum Operating Ambient Temperature
      • 140 degree Fahrenheit
      • 60 degree Celsius
    • Brand
      • Alerton
    • Pressure Type
      • Differential
    • Includes
      • Conduit Adapter meter

    Andere

    • Minimum Operating Ambient Temperature
      • -10 degree Celsius
      • 14 degree Fahrenheit
    • Maximum Operating Ambient Temperature
      • 140 degree Fahrenheit
      • 60 degree Celsius
    • Brand
      • Alerton
    • Pressure Type
      • Differential
    • Includes
      • Conduit Adapter meter
    • Minimum Operating Ambient Temperature : -10 degree Celsius|14 degree Fahrenheit
    • Maximum Operating Ambient Temperature : 140 degree Fahrenheit|60 degree Celsius
    • Brand : Alerton
    • Pressure Type : Differential
    • Includes : Conduit Adapter meter