https://buildings.honeywell.com/us/en/search-results.html

Honeywell

RAEGuard 2 PID

RAEGuard 2 PID

RAEGuard 2 PID is a fixed photoionisation detector (PID) that measures a broad range of volatile organic compounds (VOCs)

Product Overview:

RAEGuard 2 PID is a fixed photoionisation detector (PID) that measures a broad range of volatile organic compounds (VOCs). The RAEGuard 2 PID operates on 10 to 28 VDC and provides an analog (4-20mA) three-wire signal output and RS-485 Modbus digital signal output. Calibration and maintenance have been greatly simplified as the digital PID module can be easily removed in hazardous locations for calibration or maintenance.

The RAEGuard 2 PID has a graphic display and local sound alarm and LED light status indicator. In addition, Low, High, and Fault relays can be configured to trigger external alarms or process controls. A magnetic key interface enables the detector to be calibrated and operational parameters adjusted with the explosion-proof enclosure in place.

Features & Benefits:

  • Faster response time - Thanks to the sample flow-through design
  • Reduce maintenance cost - Easy to remove sensor module in hazardous locations without using of tools
  • No false alarms - Large UV lamp and better sealing allows greater sensitivity, faster speed of response and better resolution

Quick Specs:

  • Digital Smart Sensor Technology
  • Detection range 0.01 to 100 ppm, 0.1 to 1000 ppm, or 1 to 1000 ppm
  • Operates on 10 to 28 VDC and provides an analogue (4-20mA) three-wire signal output, and RS-485 Modbus digital signal output
  • Graphic display and LED light status indicator for fault and alarm conditions

Fire and Gas Consultancy Services

Others

  • Brand
    • RAE
  • Sub-Category
    • Gas Detection Sensors & Transmitters

Others

  • Brand
    • RAE
  • Sub-Category
    • Gas Detection Sensors & Transmitters
  • Brand : RAE
  • Sub-Category : Gas Detection Sensors & Transmitters
Manuals and Guides
Name
Description
File Size
Date
Size
RAEGuard2 PID Combined Manual
3.34 MB
7/15/2021
PDF 3.34 MB
Technical Note
Name
Description
File Size
Date
Size
A Guideline for Pid Instrument Response
1.45 MB
11/2/2021
PDF 1.45 MB
Technical Note 132 Upgrading Firmware On RAE Systems Instruments
820.7 KB
7/15/2021
PDF 820.7 KB
Technical Note 130 Setting Alarm Limits For Mixtures
788.83 KB
7/15/2021
PDF 788.83 KB
Technical Note 146 Turning On UV Lamps In A PID Monitor
787.55 KB
7/15/2021
PDF 787.55 KB
Technical Note 163 Addressing PID Instruments Moisture Sensitivity
944.51 KB
7/15/2021
PDF 944.51 KB
Technical Note 165 Combating Drift In Portable And Fixed PIDs
930.69 KB
7/15/2021
PDF 930.69 KB
Application Note
Name
Description
File Size
Date
Size
Application Note 201: Measuring Ammonia (NH3) With Photoionization Detectors
655.59 KB
7/15/2021
PDF 655.59 KB
Application Note 211 - PIDs For Continuous Monitoring Of VOCs
826.34 KB
7/15/2021
PDF 826.34 KB
Application Note 000: RAE Systems PID Overview
1.1 MB
7/15/2021
PDF 1.1 MB
Data Sheet
Name
Description
File Size
Date
Size
RAEGuard 2 PID Data Sheet
406.17 KB
7/15/2021
PDF 406.17 KB
Certificate
Name
Description
File Size
Date
Size
RAEGuard 2 PID Declaration of Conformity
213.06 KB
1/10/2022
PDF 213.06 KB
Name
Description
File Size
Date
Size
RAEGuard2 PID Combined Manual
3.34 MB
7/15/2021
PDF 3.34 MB
A Guideline for Pid Instrument Response
1.45 MB
11/2/2021
PDF 1.45 MB
Application Note 201: Measuring Ammonia (NH3) With Photoionization Detectors
655.59 KB
7/15/2021
PDF 655.59 KB
Technical Note 132 Upgrading Firmware On RAE Systems Instruments
820.7 KB
7/15/2021
PDF 820.7 KB
Application Note 211 - PIDs For Continuous Monitoring Of VOCs
826.34 KB
7/15/2021
PDF 826.34 KB
Technical Note 130 Setting Alarm Limits For Mixtures
788.83 KB
7/15/2021
PDF 788.83 KB
Technical Note 146 Turning On UV Lamps In A PID Monitor
787.55 KB
7/15/2021
PDF 787.55 KB
Technical Note 163 Addressing PID Instruments Moisture Sensitivity
944.51 KB
7/15/2021
PDF 944.51 KB
RAEGuard 2 PID Data Sheet
406.17 KB
7/15/2021
PDF 406.17 KB
Application Note 000: RAE Systems PID Overview
1.1 MB
7/15/2021
PDF 1.1 MB
Technical Note 165 Combating Drift In Portable And Fixed PIDs
930.69 KB
7/15/2021
PDF 930.69 KB
RAEGuard 2 PID Declaration of Conformity
213.06 KB
1/10/2022
PDF 213.06 KB
Image
SKU
Description
alt
F08-0004-000
RAEPoint, RRA2000, ATEX/IECEX For RAEGuard 2 PID, REMOTE, RM2400A, 2.4GHz
alt
D03-3021-000
Spare O-Ring Kit RAEGuard 2 PID
alt
C01-0002-000
DigiPID sensor module, ATEX/IECEx/UL, 0.1 - 1000 ppm isobutylene equivalent
alt
600-0002-001
Isobutylene 100ppm 103L
alt
600-0052-000
CO 50ppm 34L
alt
H-D03-3001-000
DISPLAY MODULE ASSY,RAEGUARD 2 PID,FOR SERVICE
alt
C01-2022-000
DigiPID Mesh Filter
alt
600-0062-000
N2 100 34L
alt
600-0001-000
Isobutylene 50ppm 34L
alt
C01-3007-100
DigiPID replacement sensor kit - Teflon construction with 3 electrodes