    The Pressure Independent Balancing and Control Valve combines a flow controller and a full stroke, full authority temperature controller in one valve.

    Overview
    This product has been discontinued.
    Honeywell will provide product support until

    The Pressure Independent Balancing and Control Valve combines a flow controller and a full stroke, full authority temperature controller in one valve. Equipped with an actuator Kombi-QM provides a full stroke modulating temperature control.

    It is suitable for use in variable and constant flow systems. They may be used as constant flow limiter in constant flow systems (without an actuator) or as a Pressure Independent Control Valve in variable flow systems. V5004T Kombi-QM is typically used for balancing and temperature control of fan coil units, air handling units, chilled ceilings and one-pipe heating systems.

    Features & Benefits:
    • Automatic balancing of differential pressure –
    • Precise pressure independent flow performance.
    • Highest energy saving potential due to efficient energy transfer and minimized pump speed.
    • Integrated measuring possibility to find the optimal set point for the pump.
    • Reduced movements of actuators as pressure fluctuation do not influence the required
    • Temperature.
    • No complex calculation needed for selection.
    • No balancing method needed for commissioning.
    • Wide range of application
    • Sizes DN15 up to DN250
    • Various versions to support standard flow rates as well as low flow and high flow needs
    • Covers two functions in one valve which reduces mounting costs
    • Easy commissioning
    • Pre-setting with visual flow scale at the valve
    • Pre-setting by hand without the need of tools
    • Pre-setting possible even when the system is running and an actuator is already mounted
    • Can balance a system even if only some parts of a building are in operation
    • Maintenance friendly
    • Emergency shut-off function with plastic cap
    • Not for permanent use
    • Measuring possibility for problematic applications.
    Certifications:
    • CE
    Name
    Date
    Size
    No Resources documents tagged to this product
    An error occurred . Please try after sometime

    _blank

    Actuator_Included@actuator_included|Actuator_Stroke_Length@actuator_stroke_length|Actuator_Voltage@actuator_voltage|Application@application|Control_Type@control_type|Controlled_Medium@controlled_medium|Leakage_Rating@leakage_rating|Maximum_Differential_Pressure@maximum_differential_pressure|Maximum_Flow_Rate_Range@maximum_flow_rate_range|Maximum_Flow_Rate_Range_Max@maximum_flow_rate_range_max|Maximum_Flow_Rate_Range_Min@maximum_flow_rate_range_min|Maximum_Medium_Temperature@maximum_medium_temperature|Minimum_Differential_Pressure@minimum_differential_pressure|Minimum_Medium_Temperature@minimum_medium_temperature|Rangeability@rangeability|Valve_Body_Material@valve_body_material|Valve_Body_Pattern@valve_body_pattern|Valve_Connection_Type@valve_connection_type|Valve_Diaphragm_Material@valve_diaphragm_material|Valve_Flow_Characteristic@valve_flow_characteristic|Valve_Plug_Material@valve_plug_material|Valve_Pressure_Rating@valve_pressure_rating|Valve_Seal_Material@valve_seal_material|Valve_Seat_Material@valve_seat_material|Valve_Size_Diameter@valve_size_diameter|Valve_Stem_Material@valve_stem_material|Valve_Trim@valve_trim|Valve_Type@valve_type

    Filters

    Part Number
    Compare
    Description
    Leaf Category
    Thumbnail
    Add to list