ECC-50/100(E) emergency command centers are multipurpose emergency voice evacuation panels for fire applications, mass notification applications, or both.

ECC-50/100(E) emergency command centers are multipurpose emergency voice evacuation panels -for fire and mass notification applications. The primary operating consoles (POCs) deliver 50 or 100W of audio power for distribution to up to eight speaker circuits. Command centers come standard with a single speaker circuit and a built-in 25 Vrms, 50W amplifier. A secondary 50W amplifier can be added for single speaker circuit backup or to increase system capacity to two speaker circuits and an additional 50W of audio power. An optional ECC-CE6 module added to the command centers will upgrade the system to a maximum of eight speaker circuit outputs.

All speaker output circuits can be wired in either Style Y (Class B) or Style Z (Class A) configuration. Command centers have -14 field-programmable messages (up to 60 seconds each), built-in field configurable pre- and post-announce tone generators and a fully supervised notification appliance circuit (NAC) with 2A of synchronized NAC power. The ECC-50/100(E) includes three built-in Form C relay contacts, a NAC follower input for triggering the onboard NAC circuit, and 500 mA special application power. A built-in power supply with switch mode technology delivers operational power to the panel and an onboard battery charger supports charging up to 26AH batteries.

For fire protection applications, the ECC-50/100(E) is an adjunct (slave) to any UL Listed FACP, providing reverse polarity or contact closure- can be used as a standalone unit for non-fire applications. For seamless integration between fire and mass notification, the ECC-50/100(E) can be directly activated via serial communication between the ES-200X, MS-9600(UD)LS, or MS-9200UDLS. Activation of the ECC-50/100(E) via other FACPs uses the eight onboard command input circuits (CMDs). Two of the eight CMD circuits can be individually field programmed for activation by an FACP notification appliance circuit reverse polarity and all eight can be activated by a contact closure. In addition, the ECC50/100(E) can be activated from a building's private branch exchange (PBX) with the integral night ring feature.

All programming is done by using a simple, built-in programming utility accessed from any laptop. For added flexibility, the ECC-50/100(E) supports both 25 and 70.7 Vrms speaker output operation. By adding a 70V transformer conversion module or an additional 70.7V secondary amplifier, the system supports 70.7V speaker devices. The ECC-50/100(E) can expand in order to accommodate larger or more complex installations. To add more control and increase system capacity, any combination of up to eight external remote consoles and up to eight distributed audio amplifiers can be connected on the external data bus and audio riser data bus to create a fully integrated command center. A fully-loaded system supports up to 1,100W of total audio power and up to 24 speaker circuit outputs.

Features &- Benefits:
  • Modular design for system flexibility and easy expansion
  • Removable terminal blocks for ease of servicing and module replacement
  • Certified for seismic applications when used with the appropriate seismic mounting kit
  • Integral supervised microphone
  • Microphone time-out feature which reverts back to prerecorded message if emergency page exceeds the programmed time
  • Field-selectable message and custom message recording capability using the local microphone, a USB port, or an external audio input- external audio input can be used for background music
  • Integral tone generators field-selectable for multiple tone types
  • Integral Dress Panel
  • Optional TR-CE semi-flush trim ring
  • System status LEDs (refer to “Controls and Indicators” in product manual LS10001-000FL-E)
Certifications:
  • UL/ULC Listed: S2424
  • CSFM: 6911-0075:0226
  • NYC Fire Department Certificate of Approval: #6152
  • FM Approved
  • UL 864
  • UL 2572
  • UFC 4-021-01
  • IBC 2012, IBC 2009, IBC 2006, IBC 2003, IBC 2000 (Seismic)
  • CBC 2007 (Seismic)

Others

  • Brand
    • Fire-Lite

Others

  • Brand
    • Fire-Lite
  • Brand : Fire-Lite
Data Sheet
Name
Description
File Size
Date
Size
ECC-RPU Remote Paging Unit Data Sheet
application/pdf 323.76 KB
5/5/2022
323.76 KB
ECC-LOC Local Operator Console Data Sheet
application/pdf 464.33 KB
4/29/2022
464.33 KB
ECC-50DA(E), ECC-50BDA ECC-125DA(E) Distributed Audio Amplifiers Data Sheet
application/pdf 298.9 KB
4/29/2022
298.9 KB
ECC-LOC Local Operator Console Data Sheet
application/pdf 329.3 KB
4/29/2022
329.3 KB
ECC-50-100 Emergency Command Center Data Sheet
application/pdf 512.83 KB
4/29/2022
512.83 KB
ECC-RM Remote Microphone Data Sheet
application/pdf 274.03 KB
4/29/2022
274.03 KB
Sales Sheet
Name
Description
File Size
Date
Size
ECC Sell Sheet
application/pdf 528.37 KB
4/29/2022
528.37 KB
Brochure
Name
Description
File Size
Date
Size
Fire-Lite Product Brochure
application/pdf 4.28 MB
4/29/2022
4.28 MB
Product Line Brochure (FL-4)
application/pdf 1 MB
4/29/2022
1 MB
Addressable Fire Alarm Control Panels
application/pdf 4.31 MB
4/29/2022
4.31 MB
Notices
Name
Description
File Size
Date
Size
Lite-Configurator 2.5 Readme File
application/pdf 205.08 KB
4/29/2022
205.08 KB
Installation Instructions
Name
Description
File Size
Date
Size
ECC-50-100 and ECC-LOC OPERATING INSTRUCTIONS
application/pdf 124.36 KB
4/29/2022
124.36 KB
Manuals and Guides
Name
Description
File Size
Date
Size
ECC-50-100 - ECC-50-100E Emergency Command Center Instruction Manual
application/pdf 3.6 MB
4/29/2022
3.6 MB
Cybersecurity Manual
application/pdf 340.86 KB
4/28/2022
340.86 KB
Others
Name
Description
File Size
Date
Size
SWIFT Control Unit, Accessories, and System Listing
application/pdf 28.4 KB
5/4/2022
28.4 KB
UOXX.S2424 Control Unit Accessories, System
application/pdf 26.66 KB
5/4/2022
26.66 KB
Control Unit Accessories, System UL Listing: S2424 Listing
application/pdf 24.75 KB
5/4/2022
24.75 KB
Name
Description
File Size
Date
Size
ECC-RPU Remote Paging Unit Data Sheet
323.76 KB
5/5/2022
323.76 KB
SWIFT Control Unit, Accessories, and System Listing
28.4 KB
5/4/2022
28.4 KB
UOXX.S2424 Control Unit Accessories, System
26.66 KB
5/4/2022
26.66 KB
Control Unit Accessories, System UL Listing: S2424 Listing
24.75 KB
5/4/2022
24.75 KB
ECC-LOC Local Operator Console Data Sheet
464.33 KB
4/29/2022
464.33 KB
ECC Sell Sheet
528.37 KB
4/29/2022
528.37 KB
ECC-50DA(E), ECC-50BDA ECC-125DA(E) Distributed Audio Amplifiers Data Sheet
298.9 KB
4/29/2022
298.9 KB
Fire-Lite Product Brochure
4.28 MB
4/29/2022
4.28 MB
Product Line Brochure (FL-4)
1 MB
4/29/2022
1 MB
ECC-LOC Local Operator Console Data Sheet
329.3 KB
4/29/2022
329.3 KB
Lite-Configurator 2.5 Readme File
205.08 KB
4/29/2022
205.08 KB
ECC-50-100 and ECC-LOC OPERATING INSTRUCTIONS
124.36 KB
4/29/2022
124.36 KB
ECC-50-100 - ECC-50-100E Emergency Command Center Instruction Manual
3.6 MB
4/29/2022
3.6 MB
ECC-50-100 Emergency Command Center Data Sheet
512.83 KB
4/29/2022
512.83 KB
Addressable Fire Alarm Control Panels
4.31 MB
4/29/2022
4.31 MB
ECC-RM Remote Microphone Data Sheet
274.03 KB
4/29/2022
274.03 KB
Cybersecurity Manual
340.86 KB
4/28/2022
340.86 KB
Image
SKU
Description
alt
ECC-50/100
Multipurpose Emergency Voice Evacuation Panel: Single Speaker Circuit: 25Vrms 50W Amplifier: 120V AC: 60 Hz: 3.5 amps
alt
ECC-50/100E
Multipurpose Emergency Voice Evacuation Panel: Single Speaker Circuit: 25Vrms 50W Amplifier: 240V AC: 50 Hz: 2.0 amps