https://buildings.honeywell.com/us/en/search-results.html

Fire Alarm Control Panels

AM-8000 Fire Detection Panel

AM-8000 are RISC high speed microprocessor fire detection control panels which can drive 2 analog loops and it’s expandable to 4 using an additional LIB-8000 card installed inside the panel.

AM-8000 are RISC high speed microprocessor fire detection control panels which can drive 2 analog loops and it’s expandable to 4 using an additional LIB-8000 card installed inside the panel. Using the high speed CAN-bus line it’s possible to expand the control panel AM-8000 from 4 to 32 loops through the connection with max 7 BB-8000 (expandable from 2 to 4 loops). Each loop, using the new Advanced protocol, can manage and supervise 159 detectors and 159 modules up to max 5088 detectors and 5088 modules. On the CAN-bus, that links AM-8000 with BB-8000, it’s possible to connect up to 7 LCD-8000-L displays in order to manage and supervise all the fire detection system. The display can be installed on the field or on the BB-8000.

Features & Benefits:
  • 4 Passwords access levels
  • Programmable text for Devices/Zones: 32 characters
  • 500 zones and 400 Logic Groups per system
  • Control-By-Event Equations (CBE) to program activations using logic operators (AND. OR. DEL, etc.) 2000 events History Log file per system
  • Real time clock
  • Self programming utility on fire detection loops with Type-ID self recognition of connected devices
  • Self recognition for double address settings
  • Algorithm to activate alarms and faults
Certifications:
  • EN54-2
  • EN54-4

Others

  • Minimum Operating Ambient Temperature
    • -5 degree Celsius
  • Minimum Operating Humidity
    • 10 Percentage
  • Operating Voltage
    • 230 voltage alternating current
  • Maximum Battery Capacity
    • 18 A·h
  • Main Frequency
    • 60hertz
    • 50hertz
  • Brand
    • NOTIFIER

Others

  • Minimum Operating Ambient Temperature
    • -5 degree Celsius
  • Minimum Operating Humidity
    • 10 Percentage
  • Operating Voltage
    • 230 voltage alternating current
  • Maximum Battery Capacity
    • 18 A·h
  • Main Frequency
    • 60hertz
    • 50hertz
  • Brand
    • NOTIFIER
  • Main Frequency : 60hertz|50hertz
  • Brand : NOTIFIER
  • Minimum Operating Ambient Temperature : -5 degree Celsius
  • Minimum Operating Humidity : 10 Percentage
  • Operating Voltage : 230 voltage alternating current
  • Maximum Battery Capacity : 18 A·h
Image
SKU
Description
alt
AM-8000.4
Fire Detection Control Panel, 4 Loop, 230V AC, 50/60Hz, 1.5A, 333x160x408mm