https://buildings.honeywell.com/us/en/search-results.html

Fire Alarm Control Panels

FireWarden® NFW2-100 Addressable FACP

FireWarden® NFW2-100 addressable fire alarm control panels (FACPs) combine digital alarm communicators/transmitters (DACTs) into one circuit board.

FireWarden® NFW2-100 addressable fire alarm control panels (FACPs) combine digital alarm communicators/transmitters (DACTs) into one circuit board. The signaling line circuit (SLC) operates using a rapid group polling communication protocol technology that polls multiple devices simultaneously for a quicker device response time. This patented technology allows a fully-loaded panel with up to 198 devices to report an incident and activate the notification circuits in under 10 seconds. With this improved polling, devices can be wired on standard twisted, unshielded wire up to a distance of 10,000 feet. Its quick-remove chassis protects the electronics during construction. The backbox can be installed allowing field wiring to be pulled. When construction is completed, the electronics can be quickly installed with just two bolts. The integral DACT transmits system status (alarms, supervisories, troubles, AC loss, etc.) to a central station via the public switched telephone network. It also allows remote and local programming of the control panel using the PS-Tools upload/download utility. In addition, the control panel may be programmed or interrogated off-site via the public switched telephone network. Any personal computer with Windows® XP or greater, a compatible modem, and PS-Tools — the upload/download software kit — may serve as a service terminal. This allows download of the entire program or upload of the entire program, history file, walk test data, current status, and system voltages. The panel can also be programmed through the FACP's keypad or via a standard PS-2 computer keyboard, which can be plugged directly into the printed circuit board. This permits easy typing of address labels and other programming information.

Features & Benefits:
  • Onboard DACT
  • Remote site or local USB port upload/download, using PS-Tools
  • Four Style Y (Class B) NACs, which can be converted to four Style Z (Class A) circuits with optional ZNAC-92 converter module (up to 6A total NAC power when using optional XRM-24B)
  • Selectable strobe synchronization for System Sensor®, Wheelock®, and Gentex® devices
  • Remote acknowledge, silence, reset, and drill via addressable monitor modules 
  • Integral 80-character LCD with backlighting
  • Real-time clock/calendar with automatic daylight saving control
  • History file with 1,000-event capacity
  • Maintenance alert warns when smoke detector dust accumulation is excessive
Certifications:
  • UL Listed: S635
  • UL Standard 864, 9th Edition
  • FM approved
  • CSFM: 7165-0028:0235
  • MEA: 120-06-E, Volume 2

Others

  • Maximum Battery Capacity
    • 18
  • Minimum Operating Humidity
    • 2 Percentage
  • Loop Capacity
    • 99
    • 198
  • Brand
    • NOTIFIER
  • Main Frequency
    • 50/60hertz
  • Display Size
    • 32
  • Networkable or Standalone
    • Networkable

Others

  • Maximum Battery Capacity
    • 18
  • Minimum Operating Humidity
    • 2 Percentage
  • Loop Capacity
    • 99
    • 198
  • Brand
    • NOTIFIER
  • Main Frequency
    • 50/60hertz
  • Display Size
    • 32
  • Networkable or Standalone
    • Networkable
  • Loop Capacity : 99|198
  • Brand : NOTIFIER
  • Main Frequency : 50/60hertz
  • Display Size : 32
  • Networkable or Standalone : Networkable
  • Maximum Battery Capacity : 18
  • Minimum Operating Humidity : 2 Percentage
Data Sheet
Name
Description
File Size
Date
Size
FireWarden-100-2(E) Rev 3 Data Sheet
application/pdf 202.17 KB
4/29/2022
202.17 KB
FireWarden-100-2(E) Rev 3 Data Sheet
application/pdf 203.79 KB
2/17/2022
203.79 KB
FireWarden 100-2 Engineering Spec (DOC)
application/msword 221.5 KB
6/11/2021
221.5 KB
Reference Guides
Name
Description
File Size
Date
Size
NOTIFIER Seismic Certificate of Compliance
application/pdf 368.19 KB
4/29/2022
368.19 KB
Notifier Battery Calculations Software Version 3.0 (Microsoft Office 64-bit Compatible) - Includes HPFF8-12 64-bit Compatibility Hotfix
application/zip 13.67 MB
4/7/2022
13.67 MB
Brochure
Name
Description
File Size
Date
Size
NOTIFIER Life Safety & Emergency Communications Systems Information Guide
application/pdf 2.68 MB
2/17/2022
2.68 MB
Small Scale Solutions Brochure
application/pdf 873.47 KB
2/17/2022
873.47 KB
Name
Description
File Size
Date
Size
FireWarden-100-2(E) Rev 3 Data Sheet
202.17 KB
4/29/2022
202.17 KB
NOTIFIER Seismic Certificate of Compliance
368.19 KB
4/29/2022
368.19 KB
Notifier Battery Calculations Software Version 3.0 (Microsoft Office 64-bit Compatible) - Includes HPFF8-12 64-bit Compatibility Hotfix
13.67 MB
4/7/2022
13.67 MB
NOTIFIER Life Safety & Emergency Communications Systems Information Guide
2.68 MB
2/17/2022
2.68 MB
FireWarden-100-2(E) Rev 3 Data Sheet
203.79 KB
2/17/2022
203.79 KB
Small Scale Solutions Brochure
873.47 KB
2/17/2022
873.47 KB
FireWarden 100-2 Engineering Spec (DOC)
221.5 KB
6/11/2021
221.5 KB