Four Zone Conventional Fire Alarm Control Panel

Four zone conventional fire alarm control panels (FACPs) are compatible with System Sensor® i³™ Series detectors providing advanced features such as drift compensation, maintenance alert, and freeze warning.

Four zone SK-4 are 24V DC fire alarm control panels (FACPs) that provide four Class B initiating device circuits and two Class B notification appliance circuits (NACs). The SK-4 NAC protocol includes the ability to silence audible devices while strobes continue to flash, using only a single pair of wires. The SK-4/E is also compatible with conventional input devices, such as 2- and 4-wire smoke detectors, pull stations, water-flow devices, tamper switches, and other normally open (NO) contact devices. Activation of a compatible smoke detector or anyNO fire alarm initiating device activates audible and visual signaling devices, illuminates an indicating LED, sounds the piezo sounder at the FACP, activates the FACP alarm relay, and operates an optional module used to notify a remote station or initiate an auxiliary control function. The SK-4/E is compatible with System Sensor® i³„¢ Series detectors providing advanced features such as drift compensation, maintenance alert, and freeze warning. Automatic synchronization of audio/visual devices is provided, using three selections for manufacturer protocol.

Features & Benefits:
  • Four Style B (Class B) initiating device circuits (IDCs)
  • Two Style Y (Class B) notification appliance circuit (NAC)
  • Optional module converts all IDCs and NACs to Class A (PN SK-CAC4)
  • Support for synchronization of standard ANSI audible signals and ADA compliant strobes per NFPA 72
  • Selectable for System Sensor, Wheelock, and Gentex protocols
  • Selective silence feature allows manual silence of horns while strobes continue to flash on the same NAC
  • Program for combination tamper supervisory monitor and waterflow alarm on one zone
  • Silent or audible walk test operation mode
  • Alarm verification selectable per zone
  • Program each zone for supervisory or fire with separate red and yellow LEDs
  • Disable switches provided per zone
  • Program NACS for – Silence inhibit – Auto silence – Strobe synchronization – Temporal or steady signal – Silenceable or nonsilenceable – Disable
  • Form C alarm, trouble, and supervisory relays
  • 3A total usable current
  • 6A total usable current with optional second transformer (PN SK-TRM24 or SK-TRM24E)
  • Optional dress panel (PN SK-DP2/4)
Certifications:
  • NFPA 72; UL Listed
  • CSFM 7165-0559: 145
  • MEA 297-01-E-3

Others

  • For Use With
    • Backbox
    • Tamper Switches and Other Normally Open Contact Devices
    • Flush Mount
    • Two and Four Wire Smoke Detectors
    • Pull Stations
    • Water-Flow Devices
  • Brand
    • Silent Knight

Others

  • For Use With
    • Backbox
    • Tamper Switches and Other Normally Open Contact Devices
    • Flush Mount
    • Two and Four Wire Smoke Detectors
    • Pull Stations
    • Water-Flow Devices
  • Brand
    • Silent Knight
  • For Use With : Backbox|Tamper Switches and Other Normally Open Contact Devices|Flush Mount|Two and Four Wire Smoke Detectors|Pull Stations|Water-Flow Devices
  • Brand : Silent Knight
Installation Instructions
Name
Description
File Size
Date
Size
SK-4 Device Compatibility
application/pdf 364.25 KB
4/11/2022
364.25 KB
SK-2 and SK-4 Conventional FACP 2 & 4 Zone Manual
application/pdf 1.24 MB
4/11/2022
1.24 MB
Manuals and Guides
Name
Description
File Size
Date
Size
SK-4 Conventional FACP Operation Card
application/pdf 89.82 KB
4/11/2022
89.82 KB
Others
Name
Description
File Size
Date
Size
SK-4 CAD Drawing
application/zip 1.13 MB
4/11/2022
1.13 MB
SK-2 Conventional FACP Operation Card
application/pdf 89.81 KB
3/13/2022
89.81 KB
SK-2 Device Compatiblity
application/pdf 364.25 KB
3/13/2022
364.25 KB
SK-2 and SK-4 Conventional FACP 2 & 4 Zone CSFM Listing
application/pdf 166.7 KB
3/13/2022
166.7 KB
Document Revision History Manual
application/pdf 46.99 KB
3/13/2022
46.99 KB
UL Listing UOJZ.S2766 Control Units, System
application/pdf 40.58 KB
3/13/2022
40.58 KB
SK-4 Conventional FACP 4 Zone Data Sheet
application/pdf 602.98 KB
3/13/2022
602.98 KB
Silent Knight Device Compatibility Document
application/pdf 161.35 KB
3/13/2022
161.35 KB
Name
Description
File Size
Date
Size
SK-4 Device Compatibility
364.25 KB
4/11/2022
364.25 KB
SK-4 Conventional FACP Operation Card
89.82 KB
4/11/2022
89.82 KB
SK-2 and SK-4 Conventional FACP 2 & 4 Zone Manual
1.24 MB
4/11/2022
1.24 MB
SK-4 CAD Drawing
1.13 MB
4/11/2022
1.13 MB
SK-2 Conventional FACP Operation Card
89.81 KB
3/13/2022
89.81 KB
SK-2 Device Compatiblity
364.25 KB
3/13/2022
364.25 KB
SK-2 and SK-4 Conventional FACP 2 & 4 Zone CSFM Listing
166.7 KB
3/13/2022
166.7 KB
Document Revision History Manual
46.99 KB
3/13/2022
46.99 KB
UL Listing UOJZ.S2766 Control Units, System
40.58 KB
3/13/2022
40.58 KB
SK-4 Conventional FACP 4 Zone Data Sheet
602.98 KB
3/13/2022
602.98 KB
Silent Knight Device Compatibility Document
161.35 KB
3/13/2022
161.35 KB
Image
SKU
Description
alt
SK-4
FACP: 120V AC: 4 Zone: Conventional