Safety Bus Modules allows fire, fire gas detection and firefighting control in a unique bus assuring a high safety level. They are composed by one or two control panel cards and can control eight supervised input for conventional sensors.

Safety Bus Modules can control eight supervised inputs for conventional sensors or detectors with safety related functions. This can include automatic, manual, water flow, and sprinkler supervision devices. All the channels can be individually reset and are tested every 30 seconds during operation. It is used to control conventional fire detectors and NO/NC contacts in general. The modules must be connected to the system ground using the screw located on the front panel.

Features & Benefits:
  • Wide area coverage
  • Easy addition of IO in existing system
  • Large capacity of 64 modules/loop
  • Redundant network
  • Available with weather proof and explosion proof housing
Certifications:
  • SIL 2/3 Certified
  • UL Approved
  • EN Atex Approved
  • CE Approved

Others

  • Minimum Operating Humidity
    • 0 percentage relative humidity
  • Output Current
    • 500 milliampere
  • Operating Voltage
    • 22 voltage direct current
    • 28 voltage direct current
  • Minimum Operating Ambient Temperature
    • -30 degree Celsius
  • Transmission Distance
    • 500 metre
  • Standby Current
    • 115 milliampere
  • Brand
    • Honeywell Industrial Fire
  • Mounting Type
    • DIN Rail
  • For Use With
    • T35 DIN Rail
  • Loop Capacity
    • 8
  • Number of outputs
    • 8

Others

  • Minimum Operating Humidity
    • 0 percentage relative humidity
  • Output Current
    • 500 milliampere
  • Operating Voltage
    • 22 voltage direct current
    • 28 voltage direct current
  • Minimum Operating Ambient Temperature
    • -30 degree Celsius
  • Transmission Distance
    • 500 metre
  • Standby Current
    • 115 milliampere
  • Brand
    • Honeywell Industrial Fire
  • Mounting Type
    • DIN Rail
  • For Use With
    • T35 DIN Rail
  • Loop Capacity
    • 8
  • Number of outputs
    • 8
  • Brand : Honeywell Industrial Fire
  • Mounting Type : DIN Rail
  • For Use With : T35 DIN Rail
  • Loop Capacity : 8
  • Number of outputs : 8
  • Minimum Operating Humidity : 0 percentage relative humidity
  • Output Current : 500 milliampere
  • Operating Voltage : 22 voltage direct current|28 voltage direct current
  • Minimum Operating Ambient Temperature : -30 degree Celsius
  • Transmission Distance : 500 metre
  • Standby Current : 115 milliampere
Image
SKU
Description
alt
SB-SIM-GM
Safety Bus Module: 22-28V: DC: IP30: 500m: 8 Supervised: Input Module: Earth Leackage Monitor
alt
SB-SIM/GM-T9001SUB
Safety Bus Module: 22-28V: DC: IP30: 500m: 8 Supervised: Transient Suppression Board: Ground Monitor
alt
SB-SIM
Safety Bus Module: 22-28V: DC: IP30: 500m: 8 Supervised: Input Module