https://buildings.honeywell.com/us/en/search-results.html

Annunciators

ANN-RLED Annunciator Module

The Notifier N-ANN-LED annunciator modules provides LED annunciation of general system faults and input zones/points when used with a compatible Fire Alarm Control Panel. The N-ANN-LED is supplied with Canadian Firewarden FACPs as required by ULC.

The Notifier N-ANN-LED annunciator modules provides LED annunciation of general system faults and input zones/points when used with a compatible Fire Alarm Control Panel (FACP). The N-ANNLED module provides alarm (red), trouble (yellow) and supervisory (yellow) indication for up to ten input zones or addressable points. N-ANN-RLED has red LEDs only for alarm communication of up to 30 addressable points.

The N-ANN-LED is supplied with Canadian Firewarden FACPs as required by ULC. The N-ANN-LED and the FACP communicate over a two-wire serial interface employing the ANN-BUS communication format. An additional two wires are used for 24-volt DC power. A single four-conductor unshielded cable may be used for both power and data communications. Up to eight ANN-BUS devices may be connected to the ANNBUS of each FACP.

Features & Benefits:
  • ANN-LED connects to the ANN-BUS terminal on the FACP and requires minimal programming.
  • Includes three LEDs for each zone: Alarm, Trouble and Supervisory.
  • Compatible with the MS-9050UD, MS-5UD-3, MS-10UD-7, MRP-2001, MRP-2002, MS9200UDLS version 4.0 or greater, MS-9600LS and MS-9600UDLS.
  • Can be remotely located up to 6,000 feet (1,829 m) from the panel.
  • May be powered by 24 VDC from the host FACP or by remote power supply.
Certifications:
  • UL: S635
  • ULC: S635 (N-ANN-LED only)
  • FM approved
  • CSFM: 7120-0028:0259
  • MEA: 333-07-E
  • Fire Dept of NY: COA #6177

Others

  • Maximum Operating Humidity
    • 93 Percentage
  • Maximum Operating Voltage
    • 24
  • Alarm Current
    • 68 milliampere
    • 28 milliampere
  • Number of Zones
    • 10
  • Light Bulb Type
    • LED

Others

  • Maximum Operating Humidity
    • 93 Percentage
  • Maximum Operating Voltage
    • 24
  • Alarm Current
    • 68 milliampere
    • 28 milliampere
  • Number of Zones
    • 10
  • Light Bulb Type
    • LED
  • Number of Zones : 10
  • Light Bulb Type : LED
  • Alarm Current : 68 milliampere|28 milliampere
  • Maximum Operating Humidity : 93 Percentage
  • Maximum Operating Voltage : 24
Installation Instructions
Name
Description
File Size
Date
Size
ANN-LED and ANN-RLED Annunciator Modules Installation Instructions
application/pdf 350.49 KB
4/29/2022
350.49 KB
Data Sheet
Name
Description
File Size
Date
Size
ANN-LED Annunciator Module Data Sheet
application/pdf 250 KB
4/29/2022
250 KB
Name
Description
File Size
Date
Size
ANN-LED and ANN-RLED Annunciator Modules Installation Instructions
350.49 KB
4/29/2022
350.49 KB
ANN-LED Annunciator Module Data Sheet
250 KB
4/29/2022
250 KB
Image
SKU
Description
alt
ANN-RLED-W
ANN-RLED Annunciator Module, 18 to 28VDC, Alarm- 68 mA, Standby-28 mA