https://buildings.honeywell.com/us/en/search-results.html
×
Outage Notification: On Saturday, June 5,12:30-2:30 p.m. EDT (6:30 to 8:30 p.m. UDT), this website will undergo planned maintenance. Thank you for your patience.

Room & Zone Controllers

Stryker™ BACnet® Configurable VAV Controller

Stryker™ BACnet® configurable (variable air volume) VAV controllers are designed to control HVAC equipment.

Stryker™ BACnet® configurable (variable air volume) VAV controllers are designed to control HVAC equipment. These controllers provide many options and advanced system features that allow state-of-the-art commercial building control. Each controller is configurable using the Niagara Framework® software. The controllers are for use in VAV control applications. Each controller provides flexible, universal inputs for external sensors, digital inputs, and a combination of analog outputs and digital outputs.

Features & Benefits:
  • Uses the BACnet® MS/TP network protocol
  • EIA-485 communication network
  • Capable of baud rates between 9.6 and 115.2 kilobits per second
  • Capable of standalone operation, but can also use BACnet network communications
  • Sylk™ bus for use with Sylk-enabled sensors
  • Support up to 30 controllers per BACnet MS/TP segment
  • Field configurable for control, input, and output functions using the Niagara Framework software
  • Built-in zone control functions include a remote wall module interface and a scheduler
  • Pressure-independent or pressure-dependent single VAV control
  • Microbridge airflow sensor with dual integral restrictor design
Certifications:
  • UL/cUL (E87741) Listed Under UL916 (Standard for Open Energy Management Equipment) with Plenum rating
  • CSA (LR95329-3) Listed
  • Meets FCC Part 15, Subpart B, Class B (Radiated Emissions) Requirements
  • Meets Canadian Standard C108.8 (Radiated Emissions)

Others

  • For Use With
    • WEBs-N4
    • WEBs-AX
  • Communications Protocol
    • BACnet MS/TP
    • BACnet
  • Power Source
    • Power Supply
  • Maximum Operating Humidity
    • 95% (Non-Condensing)
  • Number of Digital Inputs
    • 0
  • Minimum Operating Humidity
    • 5% (Non-Condensing)
  • Communication Technology
    • BACnet MS/TP
  • Application
    • VAV
  • Control Functions
    • Built-in Zone
  • Number of Universal Inputs
    • 4

Others

  • For Use With
    • WEBs-N4
    • WEBs-AX
  • Communications Protocol
    • BACnet MS/TP
    • BACnet
  • Power Source
    • Power Supply
  • Maximum Operating Humidity
    • 95% (Non-Condensing)
  • Number of Digital Inputs
    • 0
  • Minimum Operating Humidity
    • 5% (Non-Condensing)
  • Communication Technology
    • BACnet MS/TP
  • Application
    • VAV
  • Control Functions
    • Built-in Zone
  • Number of Universal Inputs
    • 4
  • For Use With : WEBs-N4|WEBs-AX
  • Communications Protocol : BACnet MS/TP|BACnet
  • Power Source : Power Supply
  • Maximum Operating Humidity : 95% (Non-Condensing)
  • Number of Digital Inputs : 0
  • Minimum Operating Humidity : 5% (Non-Condensing)
  • Communication Technology : BACnet MS/TP
  • Application : VAV
  • Control Functions : Built-in Zone
  • Number of Universal Inputs : 4
Image
SKU
Description
alt
CVB4024NS-VAV1/U
Stryker BACnet Configurable VAV Controller, 4 UI, 2 AO, 4 DO
alt
CVB4022AS-VAV1/U
Stryker BACnet Configurable VAV Controller, 4 UI, 2AO, 2 DO, Integral Actuator