https://buildings.honeywell.com/us/en/search-results.html

Monitors

Multi Monitor Modules by Notifier

NOTIFIER's intelligent, addressable multiple monitor modules are a convenient space saving platform and allow for additional mounting options.

NOTIFIER's intelligent, addressable multiple monitor modules are a convenient space saving platform and allow for additional mounting options. NZM interface provides an interface between the intelligent alarm system and a two-wire conventional detection zone. A common SLC input is used for all modules, and the initiating device circuits share a common external supervisory supply and ground. Otherwise, each module operates independently from the others.

Features & Benefits:
  • NZM-100-6 provides six zone interface circuits
  • NMM-100-10 provides ten monitor inputs Removable plug-in terminal blocks
  • Status indicators for each point
Certifications:
  • CSFM approved: 7300-0028:256
  • FM approved
  • UL Listed: S635

Others

  • Cabinet Height
    • 10.16 centimetre
    • 4 inch
  • Maximum Operating Humidity
    • 93 Percentage
  • Maximum Operating Voltage
    • 15 - 32 DC volt
  • End of Line Resistance
    • 3.9 kO
  • Cabinet Width
    • 4 inch
    • 10.16 centimetre
  • Cabinet Depth
    • 5.398 centimetre
    • 2.125 inch
  • Brand
    • NOTIFIER
  • For Use With
    • Smoke Detector
  • Approved Location
    • CSFM 7300-0028-0230
    • UL S635
    • MEA 72-01-E Vol.2
    • ULC S635
  • Maximum IDC Wiring Resistance
    • 25ohm

Others

  • Cabinet Height
    • 10.16 centimetre
    • 4 inch
  • Maximum Operating Humidity
    • 93 Percentage
  • Maximum Operating Voltage
    • 15 - 32 DC volt
  • End of Line Resistance
    • 3.9 kO
  • Cabinet Width
    • 4 inch
    • 10.16 centimetre
  • Cabinet Depth
    • 5.398 centimetre
    • 2.125 inch
  • Brand
    • NOTIFIER
  • For Use With
    • Smoke Detector
  • Approved Location
    • CSFM 7300-0028-0230
    • UL S635
    • MEA 72-01-E Vol.2
    • ULC S635
  • Maximum IDC Wiring Resistance
    • 25ohm
  • Brand : NOTIFIER
  • For Use With : Smoke Detector
  • Approved Location : CSFM 7300-0028-0230|UL S635|MEA 72-01-E Vol.2|ULC S635
  • Maximum IDC Wiring Resistance : 25ohm
  • Cabinet Height : 10.16 centimetre|4 inch
  • Maximum Operating Humidity : 93 Percentage
  • Maximum Operating Voltage : 15 - 32 DC volt
  • Cabinet Width : 4 inch|10.16 centimetre
  • Cabinet Depth : 5.398 centimetre|2.125 inch
  • End of Line Resistance : 3.9 kO
Others
Name
Description
File Size
Date
Size
Isolator Load Rating Table Brochure
application/pdf 38.09 KB
3/9/2022
38.09 KB
Name
Description
File Size
Date
Size
Isolator Load Rating Table Brochure
38.09 KB
3/9/2022
38.09 KB
Image
SKU
Description
alt
NZM-100
ADDRESSABLE 2-WIRE DETECTOR ZONE MODULE.