Temperature Controllers
AHU Temperature Controller
The standalone micro-controller based LCD temperature controller provides proportional plus integral (P+I) and on/off temperature control for commercial heating, ventilating & air conditioning system.
Please sign in to access more documents
Once signed in, you may be able to access additional documents for your account.
The standalone micro-controller based LCD temperature controller provides proportional plus integral (P+I) and on/off temperature control for commercial heating, ventilating & air conditioning system such as hydronic heating, air handling unit, heat exchanger or condensing tower. This controller has a modulating 2 to 10Vdc or 4 to 20mA analogue output and a 2A on/off output to realize various optional control functions including cool/heat changeover, heat/cool sequence control, emergency interlocking and auto-alarming control.
Features & Benefits:- PI control action provides accurate, stable and comfortable temperature control
- Backlit LCD to display both setting and measured value
- Adjustable Zero Energy Band, On/Off Differential, Proportional Band and Temperature Offset
- Optional 2 to 10Vdc or 4 to 20mA direct acting and reverse acting Analog output
- Selectable internal and external temperature sensor
- Wide temperature control range
- Watch Dog Timer to resume the controller from hanging condition
- Brownout effect to avoid malfunctioning and care on power On and power Off
- Pluggable terminal block allows pre-wiring outside of the controller
Others
- Maximum Setpoint Temperature
- 110 degree Celsius
- Overall Depth
- 17 millimetre
- Overall Height
- 115 millimetre
- Minimum Setpoint Temperature
- 5 degree Celsius
- Supply Voltage
- 24 voltage alternating current
- Overall Width
- 135 millimetre
- Number of Sensors Included
- 1
- Temperature Sensor Output
- 2 to 10Vdc or 4 to 20mA Modulating (Analog); 2A on/off (Digital) degree Fahrenheit
- For Use With
- Hydronic Heating; Air Handling Unit; Heat Exchanger; Condensing Tower volt
- Detection Sensor Type
- RTD PT1000 Temperature inch
- Supply Voltage Frequency
- 50/60 hertz
- Number of Relay Outputs
- 2
- Controller Type
- Micro-controller
- Brand
- Honeywell
Others
- Maximum Setpoint Temperature
- 110 degree Celsius
- Overall Depth
- 17 millimetre
- Overall Height
- 115 millimetre
- Minimum Setpoint Temperature
- 5 degree Celsius
- Supply Voltage
- 24 voltage alternating current
- Overall Width
- 135 millimetre
- Number of Sensors Included
- 1
- Temperature Sensor Output
- 2 to 10Vdc or 4 to 20mA Modulating (Analog); 2A on/off (Digital) degree Fahrenheit
- For Use With
- Hydronic Heating; Air Handling Unit; Heat Exchanger; Condensing Tower volt
- Detection Sensor Type
- RTD PT1000 Temperature inch
- Supply Voltage Frequency
- 50/60 hertz
- Number of Relay Outputs
- 2
- Controller Type
- Micro-controller
- Brand
- Honeywell
- Maximum Setpoint Temperature : 110 degree Celsius
- Overall Depth : 17 millimetre
- Overall Height : 115 millimetre
- Minimum Setpoint Temperature : 5 degree Celsius
- Supply Voltage : 24 voltage alternating current
- Overall Width : 135 millimetre
- Number of Sensors Included : 1
- Temperature Sensor Output : 2 to 10Vdc or 4 to 20mA Modulating (Analog); 2A on/off (Digital) degree Fahrenheit
- For Use With : Hydronic Heating; Air Handling Unit; Heat Exchanger; Condensing Tower volt
- Detection Sensor Type : RTD PT1000 Temperature inch
- Supply Voltage Frequency : 50/60 hertz
- Number of Relay Outputs : 2
- Controller Type : Micro-controller
- Brand : Honeywell
Please sign in to view part numbers available for purchase based on your account Sign In