RAEGuard 2 PID

RAEGuard 2 PID is a fixed photoionisation detector (PID) that measures a broad range of volatile organic compounds (VOCs) • Quick Specs • Digital Smart Sensor Technology • Detection range 0.01 to 100 ppm, 0.1 to 1000 ppm, or 1 to 1000 ppm

Overview


.

RAEGuard 2 PID is a fixed photoionisation detector (PID) that measures a broad range of volatile organic compounds (VOCs). The RAEGuard 2 PID operates on 10 to 28 VDC and provides an analog (4-20mA) three-wire signal output and RS-485 Modbus digital signal output. Calibration and maintenance have been greatly simplified as the digital PID module can be easily removed in hazardous locations for calibration or maintenance.
The RAEGuard 2 PID has a graphic display and local sound alarm and LED light status indicator. In addition, Low, High, and Fault relays can be configured to trigger external alarms or process controls. .A magnetic key interface enables the detector to be calibrated and operational parameters adjusted with the explosion-proof enclosure in place.
Specifications

Features & Benefits

  • Features
    • - Easy to remove sensor module in hazardous locations without using of tools
    • - Large UV lamp and better sealing allows greater sensitivity, faster speed of response and better resolution
    • - Thanks to the sample flow-through design
    • Faster response time
    • No false alarms
    • Reduce maintenance cost

Features & Benefits

  • Features
    • - Easy to remove sensor module in hazardous locations without using of tools
    • - Large UV lamp and better sealing allows greater sensitivity, faster speed of response and better resolution
    • - Thanks to the sample flow-through design
    • Faster response time
    • No false alarms
    • Reduce maintenance cost
  • Features : - Easy to remove sensor module in hazardous locations without using of tools|- Large UV lamp and better sealing allows greater sensitivity, faster speed of response and better resolution|- Thanks to the sample flow-through design|Faster response time|No false alarms|Reduce maintenance cost
Sort
Product Number
SKUs
Image
SKU
Description
alt
033-3032-000
Magnet Key, RAEGuard and RAEGuard 2
alt
033-3035-000
alt
050-0000-005
DigiPID lamp, 10.6 ev, 1/2
alt
081-0017-000
Kit, Lamp Cleaning (cleaning solution: Isopropanol)Note: The recommended cleaning fluid Isopropanol is not included.
alt
430-B082-0H0
O-Ring,40x35x2.5mm, Silicon Rubber
alt
430-B083-0H0
O-Ring,8.5x4.5x2mm, Silicon Rubber
alt
490-0011-005
DigiPID external water trap filter (Pack of 5)
alt
490-0163-000
FILTER HOUSING GLASS AND STEEL
alt
490-0164-010
FILTER REPLACEMENTS PACK OF 10
alt
490-3039-000
PLUG, 3/4" NPT, Aluminium, ATEX & CSA Certified
Image
SKU
Description
alt
033-3032-000
Magnet Key, RAEGuard and RAEGuard 2
alt
033-3035-000
alt
050-0000-005
DigiPID lamp, 10.6 ev, 1/2
alt
081-0017-000
Kit, Lamp Cleaning (cleaning solution: Isopropanol)Note: The recommended cleaning fluid Isopropanol is not included.
alt
430-B082-0H0
O-Ring,40x35x2.5mm, Silicon Rubber
alt
430-B083-0H0
O-Ring,8.5x4.5x2mm, Silicon Rubber
alt
490-0011-005
DigiPID external water trap filter (Pack of 5)
alt
490-0163-000
FILTER HOUSING GLASS AND STEEL
alt
490-0164-010
FILTER REPLACEMENTS PACK OF 10
alt
490-3039-000
PLUG, 3/4" NPT, Aluminium, ATEX & CSA Certified