Multi-Criteria Sensors

Photo Thermal Fire Detector

The NRX-OPT smoke detectors are a battery powered radio-frequency device, designed to be used with the NRXI-GATE radio gateway.

Overview

The NRX-OPT smoke detectors are a battery powered radio-frequency device, designed to be used with the NRXI-GATE radio gateway. It contains a transceiver and is integrated into a fire-fighting system that can be addressed through a proprietary communication protocol.

The unit is an optical smoke detector and should be fixed to the ceiling via the B501RF base. Standby current: 120 μA to 3 V DC (typical in normal operation mode). Red LED Current: 4mA max. Resynchronization time: 35 s (maximum time from turning on the device to normal RF communication when the network is active) Batteries: 4 Duracell Ultra 123 Battery life: 4 years at 25oC Radio frequency: 865-870 MHz; RF output power: 14 dBm (max) Range: 500 m (typical in free air) Relative humidity: 10% to 93% (no condensation).

Features & Benefits:
  • Mesh multiple communication paths for increased reliability
  • 18RF channels at 868MHz - provides greater tolerance to interference
  • 2 integrated antennas on each wireless fire device – easier positioning of devices
  • Up to 400 m free air communication range – providing good coverage levels
  • Average 5 year battery service life – reducing maintenance requirements
  • Addresses set using rotary switches – reduced commissioning time
  • Loop powered Gateway – reduced installation cost and time
  • Up to 8 Gateways per loop
  • Up to 32 Wireless devices per Gateway
Certifications:
  • CE
Specifications

Others

  • Maximum Operating Humidity
    • 93 Percentage
  • Minimum Operating Humidity
    • 10 Percentage
  • Maximum Beam Distance
    • 400 metre
  • Maximum Standby Current
    • 120 µA
  • Brand
    • Notifier
    • System Sensor
  • Detection Sensor Type
    • Photoelectric inch
  • Conventional or Addressable
    • Addressable

Others

  • Maximum Operating Humidity
    • 93 Percentage
  • Minimum Operating Humidity
    • 10 Percentage
  • Maximum Beam Distance
    • 400 metre
  • Maximum Standby Current
    • 120 µA
  • Brand
    • Notifier
    • System Sensor
  • Detection Sensor Type
    • Photoelectric inch
  • Conventional or Addressable
    • Addressable
  • Maximum Operating Humidity : 93 Percentage
  • Minimum Operating Humidity : 10 Percentage
  • Maximum Beam Distance : 400 metre
  • Maximum Standby Current : 120 µA
  • Brand : Notifier|System Sensor
  • Detection Sensor Type : Photoelectric inch
  • Conventional or Addressable : Addressable
Sort
Product Number
Image
SKU
Description
alt
NRX-OPT
Fire Detector, Photo-Thermal-IR Detector, 3V DC, 120μA, 35s, 500m, 865-870MHz
Image
SKU
Description
alt
NRX-OPT
Fire Detector, Photo-Thermal-IR Detector, 3V DC, 120μA, 35s, 500m, 865-870MHz