    DDCM Differential pressure switches are suitable for monitoring and controlling differential pressures, flow monitoring and automatic control of filter systems. A double chamber system with stainless steel bellows or Perbunan diaphragm detects the difference between the two applied pressures. The desired switching pressure is continuously adjustable within the ranges listed. All differential pressure monitors can also be used in the vacuum range. The switching differential is not adjustable.It comes with Robust housing made of seawater resistant die cast aluminium GD Al Si 12.Mounting directly on the pressure line or on a flatsurface with two 4 mm Ø screws.Note the connection of pressurized lines:P (+) = high pressureS (–) = low pressure

    Features & Benefits:
    • The DDCM series are calibrated for falling pressure
    • This means that the adjustable pressure on the scale corresponds to the switching point at falling pressure
    • The reset point is higher by the amount of the switching differential
    Certifications:
    • SIL2 according IEC 61508-2
    Specifications

    Others

    • Minimum Operating Ambient Temperature
      • -25
    • Maximum Operating Ambient Temperature
      • 70
    • Brand
      • CentraLine
      • FEMA
    • Switch Configuration
      • 8 A bei 250 , 5 A bei 250 induktiv, 8 A bei 24 V DC, 0,3 A bei 250 V DC
      • SPDT Microswitch; Capacity 5 A Inductive, 8 A Resistive
      • SPDT Microswitch; Capacity 5 A Inductive, 8 A Resistive
    • Pressure Type
      • Differential Pressure, Relative
      • Differential Pressure, Relative
      • Differenzdruck relativ
      • verschildruk relatief
    • Connection Type
      • Internal Thread G1/4 in

    Others

    • Minimum Operating Ambient Temperature
      • -25
    • Maximum Operating Ambient Temperature
      • 70
    • Brand
      • CentraLine
      • FEMA
    • Switch Configuration
      • 8 A bei 250 , 5 A bei 250 induktiv, 8 A bei 24 V DC, 0,3 A bei 250 V DC
      • SPDT Microswitch; Capacity 5 A Inductive, 8 A Resistive
      • SPDT Microswitch; Capacity 5 A Inductive, 8 A Resistive
    • Pressure Type
      • Differential Pressure, Relative
      • Differential Pressure, Relative
      • Differenzdruck relativ
      • verschildruk relatief
    • Connection Type
      • Internal Thread G1/4 in
    • Minimum Operating Ambient Temperature : -25
    • Maximum Operating Ambient Temperature : 70
    • Brand : CentraLine|FEMA
    • Switch Configuration : 8 A bei 250 , 5 A bei 250 induktiv, 8 A bei 24 V DC, 0,3 A bei 250 V DC|SPDT Microswitch; Capacity 5 A Inductive, 8 A Resistive|SPDT Microswitch; Capacity 5 A Inductive, 8 A Resistive
    • Pressure Type : Differential Pressure, Relative|Differential Pressure, Relative|Differenzdruck relativ|verschildruk relatief
    • Connection Type : Internal Thread G1/4 in
    Name
    Date
    Size
    No Resources documents tagged to this product
    An error occurred . Please try after sometime

    _blank

    Approval_Type@approval_type|Direction_Of_Action@direction_of_action|Enclosure_Rating@enclosure_rating|Medium@medium|Pressure_Sensor_Type@pressure_sensor_type|Reset@reset|Sensing_Element_Material@sensing_element_material|Sensor_Type@sensor_type

    Filters

    Product Number
    Part Number
    Compare
    Description
    Leaf Category
    Thumbnail
    Add to list
    DDCM014
    Differential Pressure Switch, SPCO; differential not adjustable; setting range: –0,1…0,4 bar; switching differential: 50 ... 180mbar; max pressure: 15bar
    https://preview1.assetsadobe.com/is/image/Honeywell65/hon-ba-bms-ddcm1-left
    DDCM014
    Differential Pressure Switch, SPCO; differential not adjustable; setting range: –0,1…0,4 bar; switching differential: 50 ... 180mbar; max pressure: 15bar
    https://preview1.assetsadobe.com/is/image/Honeywell65/hon-ba-bms-ddcm1-left
    DDCM1
    Differential Pressure Switch, SPCO; differential not adjustable; setting range: 0,2…1,6 bar; switching differential: 80 ... 180mbar; max pressure: 15bar
    https://preview1.assetsadobe.com/is/image/Honeywell65/hon-ba-bms-ddcm1-left
    DDCM1
    Differential Pressure Switch, SPCO; differential not adjustable; setting range: 0,2…1,6 bar; switching differential: 80 ... 180mbar; max pressure: 15bar
    https://preview1.assetsadobe.com/is/image/Honeywell65/hon-ba-bms-ddcm1-left
    DDCM16
    Differential Pressure Switch, SPCO; differential not adjustable; setting range: 3…16 bar; switching differential: 0,2 ... 0,8bar; max pressure: 25bar
    https://preview1.assetsadobe.com/is/image/Honeywell65/hon-ba-bms-ddcm1-left
    DDCM16
    Differential Pressure Switch, SPCO; differential not adjustable; setting range: 3…16 bar; switching differential: 0,2 ... 0,8bar; max pressure: 25bar
    https://preview1.assetsadobe.com/is/image/Honeywell65/hon-ba-bms-ddcm1-left
    DDCM16-513
    Differential Pressure Switch, SPCO; differential not adjustable; setting range: 3…16 bar; switching differential: 0,2 ... 0,8bar; max pressure: 25bar; gold plated contacts; EX-i
    DDCM16-513
    Differential Pressure Switch, SPCO; differential not adjustable; setting range: 3…16 bar; switching differential: 0,2 ... 0,8bar; max pressure: 25bar; gold plated contacts; EX-i
    DDCM252
    Differential Pressure Switch, SPCO; differential not adjustable; setting range: 4…25 mbar; switching differential: 0,7 ... 4 mbar; max pressure: 0,5bar
    DDCM252
    Differential Pressure Switch, SPCO; differential not adjustable; setting range: 4…25 mbar; switching differential: 0,7 ... 4 mbar; max pressure: 0,5bar
    DDCM4
    Differential Pressure Switch, SPCO; differential not adjustable; setting range: 1…4 bar; switching differential: 0,1 ... 0,3bar; max pressure: 25bar
    https://preview1.assetsadobe.com/is/image/Honeywell65/hon-ba-bms-ddcm1-left
    DDCM4
    Differential Pressure Switch, SPCO; differential not adjustable; setting range: 1…4 bar; switching differential: 0,1 ... 0,3bar; max pressure: 25bar
    https://preview1.assetsadobe.com/is/image/Honeywell65/hon-ba-bms-ddcm1-left
    DDCM6
    Differential Pressure Switch, SPCO; differential not adjustable; setting range: 0,5…6 bar; switching differential: 0,1 ... 0,3bar; max pressure: 15bar
    https://preview1.assetsadobe.com/is/image/Honeywell65/hon-ba-bms-ddcm1-left
    DDCM6
    Differential Pressure Switch, SPCO; differential not adjustable; setting range: 0,5…6 bar; switching differential: 0,1 ... 0,3bar; max pressure: 15bar
    https://preview1.assetsadobe.com/is/image/Honeywell65/hon-ba-bms-ddcm1-left
    DDCM6002
    Differential Pressure Switch, SPCO; differential not adjustable; setting range: 100…600 mbar; switching differential: 2 ... 40mbar; max pressure: 3bar
    DDCM6002
    Differential Pressure Switch, SPCO; differential not adjustable; setting range: 100…600 mbar; switching differential: 2 ... 40mbar; max pressure: 3bar
    DDCM662
    Differential Pressure Switch, SPCO; differential not adjustable; setting range: 10…60 mbar; switching differential: 2 ... 23mbar; max pressure: 1,5bar
    DDCM662