/content/hbtbt/gb/en/search-results.html

    Pressure Switches & Sensors

    Ex-DGM Pressure monitors for fuel gases

    DVGW tested to DIN EN1854 Gas pressure monitors are suitable for all gases in accordance with DVGW work sheet G260 and for air.

    Overview

    Ex-DGM Pressure monitors for fuel gases are DVGW tested to DIN EN1854 Gas pressure monitors suitable for all gases in accordance with DVGW work sheet G260 and for air.It comes with with a robust housing of Seawater resistant die cast aluminium GD AI Si 12.Switching differentials are largely dependent of the set witching pressure and not adjustable.

    Features & Benefits:
    • The DGM series is calibrated for rising pressure. This means that the adjustable switching pressure on the scale corresponds to the switching point at rising pressure. The reset point is lower by the amount of the switching differential
    • For maximum and minimumpressure monitoring
    Certifications:
    • CE-0085 AQ 1088 according EU/2009/142/EG (30.11.2009) and DIN EN 1854 (01.07.2006)
    • IBExU12ATEX1040 according ATEX 2014/34/EU
    • SIL2 according IEC 61508-2
    Others
    Name
    Description
    File Size
    Date
    Size
    Installation instructions-DWR,DGM,EX-DWR,EX-DGM Pressure Monitors & Pressure Limiters-RU
    application/pdf 494.21 KB
    494.21 KB
    FEMA Pressure Switch and thermostat type range
    application/pdf 250.54 KB
    7/17/2024
    250.54 KB
    Pressure and temperature switches
    application/pdf 190.48 KB
    7/17/2024
    190.48 KB
    M6410C/L,M7410C Fiche Produit (FR)
    application/pdf 148.32 KB
    7/17/2024
    148.32 KB
    DGM pressure switch series for explosive atmosphere environment
    application/pdf 307.66 KB
    7/17/2024
    307.66 KB
    DGM drukschakelaar serie voor explosieve atmosfeer milieu
    application/pdf 81.2 KB
    7/17/2024
    81.2 KB
    ЕВРАЗИЙСКИЙ ЭКОНОМИЧЕСКИЙ СОЮЗ ДЕКЛАРАЦИЯ О СООТВЕТСТВИИ
    application/pdf 1.95 MB
    7/17/2024
    1.95 MB
    Installation and Operating Instructions - DCM,DNM,DNS,VCM,VNM,VNS,DDCM,EX-DCM,EX-DNM,EX-DNS,EX-VNS,EX-DDCM,EX-VCM,EX-VNM (Hungarian)
    application/pdf 628.13 KB
    7/17/2024
    628.13 KB
    V5016A Fiche Technique (FR)
    application/pdf 141.85 KB
    7/17/2024
    141.85 KB
    Vanne linéaire compacte PN16 pour régulation tout - rien et modulante
    application/pdf 228.32 KB
    7/17/2024
    228.32 KB
    Installation and Operating Instructions - DWR,DGM,EX-DWR,EX-DGM (German and English)
    application/pdf 1.73 MB
    7/17/2024
    1.73 MB
    M6061 MOTEURS POUR VANNES ROTATIVES
    application/pdf 435.11 KB
    7/17/2024
    435.11 KB
    Technical Datasheet - EX-DGM Pressure Monitors for fuel gases (German)
    application/pdf 711.45 KB
    7/17/2024
    711.45 KB
    MOTEUR THERMIQUE LINEAIRE COMPACT
    application/pdf 246.49 KB
    7/17/2024
    246.49 KB
    Installation instructions-DWR,DGM,EX-DWR,EX-DGM Pressure Monitors & Pressure Limiters-CZ
    application/pdf 505.49 KB
    505.49 KB
    Installation instructions-DWR,DGM,EX-DWR,EX-DGM Pressure Monitors & Pressure Limiters-HU
    application/pdf 542.82 KB
    542.82 KB
    Installation instructions-DWR,DGM,EX-DWR,EX-DGM Pressure Monitors & Pressure Limiters-EN
    application/pdf 604.6 KB
    604.6 KB
    Installation instructions-DWR,DGM,EX-DWR,EX-DGM Pressure Monitors & Pressure Limiters-IT
    application/pdf 516.9 KB
    516.9 KB
    Installation instructions-DWR,DGM,EX-DWR,EX-DGM Pressure Monitors & Pressure Limiters-DA
    application/pdf 513.5 KB
    513.5 KB
    Installation instructions-DWR,DGM,EX-DWR,EX-DGM Pressure Monitors & Pressure Limiters-ES
    application/pdf 501.83 KB
    7/11/2024
    501.83 KB
    Installation instructions-DWR,DGM,EX-DWR,EX-DGM Pressure Monitors & Pressure Limiters-DE
    application/pdf 608.51 KB
    608.51 KB
    Installation instructions-DWR,DGM,EX-DWR,EX-DGM Pressure Monitors & Pressure Limiters-FI
    application/pdf 515.66 KB
    7/11/2024
    515.66 KB
    Installation instructions-DWR,DGM,EX-DWR,EX-DGM Pressure Monitors & Pressure Limiters-FR
    application/pdf 516.46 KB
    516.46 KB
    Installation instructions-DWR,DGM,EX-DWR,EX-DGM Pressure Monitors & Pressure Limiters-PL
    application/pdf 514.85 KB
    514.85 KB
    Installation instructions-DWR,DGM,EX-DWR,EX-DGM Pressure Monitors & Pressure Limiters-SV
    application/pdf 525.56 KB
    525.56 KB
    Name
    Description
    File Size
    Date
    Size
    Installation instructions-DWR,DGM,EX-DWR,EX-DGM Pressure Monitors & Pressure Limiters-RU
    application/pdf 494.21 KB
    494.21 KB
    FEMA Pressure Switch and thermostat type range
    application/pdf 250.54 KB
    7/17/2024
    250.54 KB
    Pressure and temperature switches
    application/pdf 190.48 KB
    7/17/2024
    190.48 KB
    M6410C/L,M7410C Fiche Produit (FR)
    application/pdf 148.32 KB
    7/17/2024
    148.32 KB
    DGM pressure switch series for explosive atmosphere environment
    application/pdf 307.66 KB
    7/17/2024
    307.66 KB
    DGM drukschakelaar serie voor explosieve atmosfeer milieu
    application/pdf 81.2 KB
    7/17/2024
    81.2 KB
    ЕВРАЗИЙСКИЙ ЭКОНОМИЧЕСКИЙ СОЮЗ ДЕКЛАРАЦИЯ О СООТВЕТСТВИИ
    application/pdf 1.95 MB
    7/17/2024
    1.95 MB
    Installation and Operating Instructions - DCM,DNM,DNS,VCM,VNM,VNS,DDCM,EX-DCM,EX-DNM,EX-DNS,EX-VNS,EX-DDCM,EX-VCM,EX-VNM (Hungarian)
    application/pdf 628.13 KB
    7/17/2024
    628.13 KB
    V5016A Fiche Technique (FR)
    application/pdf 141.85 KB
    7/17/2024
    141.85 KB
    Vanne linéaire compacte PN16 pour régulation tout - rien et modulante
    application/pdf 228.32 KB
    7/17/2024
    228.32 KB
    Installation and Operating Instructions - DWR,DGM,EX-DWR,EX-DGM (German and English)
    application/pdf 1.73 MB
    7/17/2024
    1.73 MB
    M6061 MOTEURS POUR VANNES ROTATIVES
    application/pdf 435.11 KB
    7/17/2024
    435.11 KB
    Technical Datasheet - EX-DGM Pressure Monitors for fuel gases (German)
    application/pdf 711.45 KB
    7/17/2024
    711.45 KB
    MOTEUR THERMIQUE LINEAIRE COMPACT
    application/pdf 246.49 KB
    7/17/2024
    246.49 KB
    Installation instructions-DWR,DGM,EX-DWR,EX-DGM Pressure Monitors & Pressure Limiters-CZ
    application/pdf 505.49 KB
    505.49 KB
    Installation instructions-DWR,DGM,EX-DWR,EX-DGM Pressure Monitors & Pressure Limiters-HU
    application/pdf 542.82 KB
    542.82 KB
    Installation instructions-DWR,DGM,EX-DWR,EX-DGM Pressure Monitors & Pressure Limiters-EN
    application/pdf 604.6 KB
    604.6 KB
    Installation instructions-DWR,DGM,EX-DWR,EX-DGM Pressure Monitors & Pressure Limiters-IT
    application/pdf 516.9 KB
    516.9 KB
    Installation instructions-DWR,DGM,EX-DWR,EX-DGM Pressure Monitors & Pressure Limiters-DA
    application/pdf 513.5 KB
    513.5 KB
    Installation instructions-DWR,DGM,EX-DWR,EX-DGM Pressure Monitors & Pressure Limiters-ES
    application/pdf 501.83 KB
    7/11/2024
    501.83 KB
    Installation instructions-DWR,DGM,EX-DWR,EX-DGM Pressure Monitors & Pressure Limiters-DE
    application/pdf 608.51 KB
    608.51 KB
    Installation instructions-DWR,DGM,EX-DWR,EX-DGM Pressure Monitors & Pressure Limiters-FI
    application/pdf 515.66 KB
    7/11/2024
    515.66 KB
    Installation instructions-DWR,DGM,EX-DWR,EX-DGM Pressure Monitors & Pressure Limiters-FR
    application/pdf 516.46 KB
    516.46 KB
    Installation instructions-DWR,DGM,EX-DWR,EX-DGM Pressure Monitors & Pressure Limiters-PL
    application/pdf 514.85 KB
    514.85 KB
    Installation instructions-DWR,DGM,EX-DWR,EX-DGM Pressure Monitors & Pressure Limiters-SV
    application/pdf 525.56 KB
    525.56 KB
    Name
    Description
    File Size
    Date
    Size
    Installation instructions-DWR,DGM,EX-DWR,EX-DGM Pressure Monitors & Pressure Limiters-RU
    494.21 KB
    FEMA Pressure Switch and thermostat type range
    250.54 KB
    7/17/2024
    Pressure and temperature switches
    190.48 KB
    7/17/2024
    M6410C/L,M7410C Fiche Produit (FR)
    148.32 KB
    7/17/2024
    DGM pressure switch series for explosive atmosphere environment
    307.66 KB
    7/17/2024
    DGM drukschakelaar serie voor explosieve atmosfeer milieu
    81.2 KB
    7/17/2024
    ЕВРАЗИЙСКИЙ ЭКОНОМИЧЕСКИЙ СОЮЗ ДЕКЛАРАЦИЯ О СООТВЕТСТВИИ
    1.95 MB
    7/17/2024
    Installation and Operating Instructions - DCM,DNM,DNS,VCM,VNM,VNS,DDCM,EX-DCM,EX-DNM,EX-DNS,EX-VNS,EX-DDCM,EX-VCM,EX-VNM (Hungarian)
    628.13 KB
    7/17/2024
    V5016A Fiche Technique (FR)
    141.85 KB
    7/17/2024
    Vanne linéaire compacte PN16 pour régulation tout - rien et modulante
    228.32 KB
    7/17/2024
    Installation and Operating Instructions - DWR,DGM,EX-DWR,EX-DGM (German and English)
    1.73 MB
    7/17/2024
    M6061 MOTEURS POUR VANNES ROTATIVES
    435.11 KB
    7/17/2024
    Technical Datasheet - EX-DGM Pressure Monitors for fuel gases (German)
    711.45 KB
    7/17/2024
    MOTEUR THERMIQUE LINEAIRE COMPACT
    246.49 KB
    7/17/2024
    Installation instructions-DWR,DGM,EX-DWR,EX-DGM Pressure Monitors & Pressure Limiters-CZ
    505.49 KB
    Installation instructions-DWR,DGM,EX-DWR,EX-DGM Pressure Monitors & Pressure Limiters-HU
    542.82 KB
    Installation instructions-DWR,DGM,EX-DWR,EX-DGM Pressure Monitors & Pressure Limiters-EN
    604.6 KB
    Installation instructions-DWR,DGM,EX-DWR,EX-DGM Pressure Monitors & Pressure Limiters-IT
    516.9 KB
    Installation instructions-DWR,DGM,EX-DWR,EX-DGM Pressure Monitors & Pressure Limiters-DA
    513.5 KB
    Installation instructions-DWR,DGM,EX-DWR,EX-DGM Pressure Monitors & Pressure Limiters-ES
    501.83 KB
    7/11/2024
    Installation instructions-DWR,DGM,EX-DWR,EX-DGM Pressure Monitors & Pressure Limiters-DE
    608.51 KB
    Installation instructions-DWR,DGM,EX-DWR,EX-DGM Pressure Monitors & Pressure Limiters-FI
    515.66 KB
    7/11/2024
    Installation instructions-DWR,DGM,EX-DWR,EX-DGM Pressure Monitors & Pressure Limiters-FR
    516.46 KB
    Installation instructions-DWR,DGM,EX-DWR,EX-DGM Pressure Monitors & Pressure Limiters-PL
    514.85 KB
    Installation instructions-DWR,DGM,EX-DWR,EX-DGM Pressure Monitors & Pressure Limiters-SV
    525.56 KB
    Product Number
    Part Number
    Description
    Leaf Category
    Thumbnail
    Add to list
    EX-DGM506
    Pressure Monitor for Fuel Gas to DIN EN1854 and ATEX 201434EU; differential not adjustable; setting range: 15…60 mbar; switching differential: 7 ... 11 mbar; max pressure: 5 bar
    https://honeywell.scene7.com/is/image/Honeywell65/hbt-bms-ex-dgm525-s-ex-dgm-series-pressure-monitor-for-burnable-gas-primaryimage
    EX-DGM506
    Pressure Monitor for Fuel Gas to DIN EN1854 and ATEX 201434EU; differential not adjustable; setting range: 15…60 mbar; switching differential: 7 ... 11 mbar; max pressure: 5 bar
    https://honeywell.scene7.com/is/image/Honeywell65/hbt-bms-ex-dgm525-s-ex-dgm-series-pressure-monitor-for-burnable-gas-primaryimage
    EX-DGM506-S
    Pressure Monitor for Fuel Gas to DIN EN1854 and ATEX 201434EU; differential not adjustable; setting range: 15…60 mbar; switching differential: 7 ... 11 mbar; max pressure: 5 bar; with service function
    https://honeywell.scene7.com/is/image/Honeywell65/hbt-bms-ex-dgm525-s-ex-dgm-series-pressure-monitor-for-burnable-gas-primaryimage
    EX-DGM506-S
    Pressure Monitor for Fuel Gas to DIN EN1854 and ATEX 201434EU; differential not adjustable; setting range: 15…60 mbar; switching differential: 7 ... 11 mbar; max pressure: 5 bar; with service function
    https://honeywell.scene7.com/is/image/Honeywell65/hbt-bms-ex-dgm525-s-ex-dgm-series-pressure-monitor-for-burnable-gas-primaryimage
    EX-DGM516
    Pressure Monitor for Fuel Gas to DIN EN1854 and ATEX 201434EU; differential not adjustable; setting range: 40…160 mbar; switching differential: 3 ... 18 mbar; max pressure: 5 bar
    https://honeywell.scene7.com/is/image/Honeywell65/hbt-bms-ex-dgm516-door-chime-primaryimage
    EX-DGM516
    Pressure Monitor for Fuel Gas to DIN EN1854 and ATEX 201434EU; differential not adjustable; setting range: 40…160 mbar; switching differential: 3 ... 18 mbar; max pressure: 5 bar
    https://honeywell.scene7.com/is/image/Honeywell65/hbt-bms-ex-dgm516-door-chime-primaryimage
    EX-DGM516-S
    Pressure Monitor for Fuel Gas to DIN EN1854 and ATEX 201434EU; differential not adjustable; setting range: 40…160 mbar; switching differential: 3 ... 18 mbar; max pressure: 5 bar; with service function
    https://honeywell.scene7.com/is/image/Honeywell65/hbt-bms-ex-dgm525-s-ex-dgm-series-pressure-monitor-for-burnable-gas-primaryimage
    EX-DGM516-S
    Pressure Monitor for Fuel Gas to DIN EN1854 and ATEX 201434EU; differential not adjustable; setting range: 40…160 mbar; switching differential: 3 ... 18 mbar; max pressure: 5 bar; with service function
    https://honeywell.scene7.com/is/image/Honeywell65/hbt-bms-ex-dgm525-s-ex-dgm-series-pressure-monitor-for-burnable-gas-primaryimage
    EX-DGM525
    Pressure Monitor for Fuel Gas to DIN EN1854 and ATEX 201434EU; differential not adjustable; setting range: 100…250 mbar; switching differential: 3 ... 18 mbar; max pressure: 5 bar
    https://honeywell.scene7.com/is/image/Honeywell65/hbt-bms-ex-dgm525-s-ex-dgm-series-pressure-monitor-for-burnable-gas-primaryimage
    EX-DGM525
    Pressure Monitor for Fuel Gas to DIN EN1854 and ATEX 201434EU; differential not adjustable; setting range: 100…250 mbar; switching differential: 3 ... 18 mbar; max pressure: 5 bar
    https://honeywell.scene7.com/is/image/Honeywell65/hbt-bms-ex-dgm525-s-ex-dgm-series-pressure-monitor-for-burnable-gas-primaryimage