/content/hbtbt/gb/en/search-results.html

    Pressure Switches & Sensors

    Ex-DNS / Ex-VNS Pressure Switches and vacuum switches with stainless steel sensors (14571)

    Pressure switches of the DNS series are suitable for monitoring and controlling pressures in chemical plants, process engineering and any situation where the pressure of aggressive liquids and gases must be monitored.

    Overview

    Ex-DNS / Ex-VNS Pressure Switches and vacuum switches with stainless steel sensors (1.4571) are are suitable for monitoring and controlling pressures in chemical plants, process engineering and any situation where the pressure of aggressive liquids and gases must be monitored. All components of the sensor system are made from highquality stainless steel (1.4571) and welded using the latest methods without filler metals. The pressure sensor is gasket free plasma welded.It comes with robust housing made of seawaterresistant die cast aluminium GD Al Si 12.The die cast aluminium housing in GD Al Si ischromated and stove enamelled with resistantplastic. Corrosion tests with 3% saline solutionand 30 temperature changes from +10 to+80°C showed no surface changes after 20days.For Ex-DNS /Ex-VNS switching differential is not adjustable.

    Features & Benefits:
    • The Ex-DNS and Ex-VNS series are calibrated for falling pressure. This means that the adjustableswitching pressure on the scale corresponds to the switching point at falling pressure. The reset point is higher by the amount of the switching differential.
    Certifications:
    • IBExU12ATEX1040 according ATEX 2014/34/EU
    • IECEx IBE 14.0077
    • SIL2 according IEC 61508-2
    Specifications

    Others

    • Switching Differential
      • 0.002 bar (air pressure)
    • Minimum Operating Ambient Temperature
      • -20
    • Maximum Operating Ambient Temperature
      • 60
    • Switch Configuration
      • 3 A bei 250 , 2 A bei 250 induktiv, 3 A bei 24 V DC, 0,03 A bei 250 V DC
      • 3 A bei 250 , 2 A bei 250 induktiv, 3 A bei 24 V DC, 0,03 A bei 250 V DC
      • SPDT Microswitch; Capacity 2 A Inductive, 3 A Resistive
      • SPDT Microswitch; Capacity 2 A Inductive, 3 A Resistive
    • Pressure Type
      • Overpressure Relative
      • overdruk relatief
      • sobrepresión relativa
      • sovrapressione relativa
      • surpression relative
      • Überdruck relativ
    • Scale Calibration
      • falling pressure
    • Connection Type
      • Internal Thread G1/4 in, External Thread G1/2 in
    • Brand
      • FEMA
      • Honeywell

    Others

    • Switching Differential
      • 0.002 bar (air pressure)
    • Minimum Operating Ambient Temperature
      • -20
    • Maximum Operating Ambient Temperature
      • 60
    • Switch Configuration
      • 3 A bei 250 , 2 A bei 250 induktiv, 3 A bei 24 V DC, 0,03 A bei 250 V DC
      • 3 A bei 250 , 2 A bei 250 induktiv, 3 A bei 24 V DC, 0,03 A bei 250 V DC
      • SPDT Microswitch; Capacity 2 A Inductive, 3 A Resistive
      • SPDT Microswitch; Capacity 2 A Inductive, 3 A Resistive
    • Pressure Type
      • Overpressure Relative
      • overdruk relatief
      • sobrepresión relativa
      • sovrapressione relativa
      • surpression relative
      • Überdruck relativ
    • Scale Calibration
      • falling pressure
    • Connection Type
      • Internal Thread G1/4 in, External Thread G1/2 in
    • Brand
      • FEMA
      • Honeywell
    • Switching Differential : 0.002 bar (air pressure)
    • Minimum Operating Ambient Temperature : -20
    • Maximum Operating Ambient Temperature : 60
    • Switch Configuration : 3 A bei 250 , 2 A bei 250 induktiv, 3 A bei 24 V DC, 0,03 A bei 250 V DC|3 A bei 250 , 2 A bei 250 induktiv, 3 A bei 24 V DC, 0,03 A bei 250 V DC|SPDT Microswitch; Capacity 2 A Inductive, 3 A Resistive|SPDT Microswitch; Capacity 2 A Inductive, 3 A Resistive
    • Pressure Type : Overpressure Relative|overdruk relatief|sobrepresión relativa|sovrapressione relativa|surpression relative|Überdruck relativ
    • Scale Calibration : falling pressure
    • Connection Type : Internal Thread G1/4 in, External Thread G1/2 in
    • Brand : FEMA|Honeywell
    Name
    Date
    Size
    No Resources documents tagged to this product
    An error occurred . Please try after sometime
    Product Number
    Part Number
    Description
    Leaf Category
    Thumbnail
    Add to list
    EX-DNS025
    Pressure Switch with Stainless Steel Sensor to ATEX 201434EU, SPCO; differential not adjustable; setting range: 0,04…0,25 bar; switching differential: 20 ... 37 mbar; max pressure: 6 bar
    https://honeywell.scene7.com/is/image/Honeywell65/hbt-bms-ex-pressure-switch-primaryimage
    EX-DNS025
    Pressure Switch with Stainless Steel Sensor to ATEX 201434EU, SPCO; differential not adjustable; setting range: 0,04…0,25 bar; switching differential: 20 ... 37 mbar; max pressure: 6 bar
    https://honeywell.scene7.com/is/image/Honeywell65/hbt-bms-ex-pressure-switch-primaryimage
    EX-DNS025-S
    Pressure Switch with Stainless Steel Sensor to ATEX 201434EU, SPCO; differential not adjustable; setting range: 0,04…0,25 bar; switching differential: 20 ... 37 mbar; max pressure: 6 bar, with service function
    https://s7d1.scene7.com/is/image/Honeywell65/hbt-bms-ex-dns025-s-ex-dns-saftey-manual-pressure-switch-primaryimage
    EX-DNS025-S
    Pressure Switch with Stainless Steel Sensor to ATEX 201434EU, SPCO; differential not adjustable; setting range: 0,04…0,25 bar; switching differential: 20 ... 37 mbar; max pressure: 6 bar, with service function
    https://s7d1.scene7.com/is/image/Honeywell65/hbt-bms-ex-dns025-s-ex-dns-saftey-manual-pressure-switch-primaryimage
    EX-DNS06
    Pressure Switch with Stainless Steel Sensor to ATEX 201434EU, SPCO; differential not adjustable; setting range: 0,1…0,6 bar; switching differential: 10 ... 35 mbar; max pressure: 6 bar
    https://honeywell.scene7.com/is/image/Honeywell65/hbt-bms-ex-pressure-switch-primaryimage
    EX-DNS06
    Pressure Switch with Stainless Steel Sensor to ATEX 201434EU, SPCO; differential not adjustable; setting range: 0,1…0,6 bar; switching differential: 10 ... 35 mbar; max pressure: 6 bar
    https://honeywell.scene7.com/is/image/Honeywell65/hbt-bms-ex-pressure-switch-primaryimage
    EX-DNS1
    Pressure Switch with Stainless Steel Sensor to ATEX 201434EU, SPCO; differential not adjustable; setting range: 0,2…1,6 bar; switching differential: 10 ... 40 mbar; max pressure: 6 bar
    https://honeywell.scene7.com/is/image/Honeywell65/hbt-bms-ex-pressure-switch-primaryimage
    EX-DNS1
    Pressure Switch with Stainless Steel Sensor to ATEX 201434EU, SPCO; differential not adjustable; setting range: 0,2…1,6 bar; switching differential: 10 ... 40 mbar; max pressure: 6 bar
    https://honeywell.scene7.com/is/image/Honeywell65/hbt-bms-ex-pressure-switch-primaryimage
    EX-DNS10
    Pressure Switch with Stainless Steel Sensor to ATEX 201434EU, SPCO; differential not adjustable; setting range: 1…10 bar; switching differential: 0,05 ... 0,3 bar; max pressure: 16 bar
    https://honeywell.scene7.com/is/image/Honeywell65/hbt-bms-ex-pressure-switch-primaryimage
    EX-DNS10
    Pressure Switch with Stainless Steel Sensor to ATEX 201434EU, SPCO; differential not adjustable; setting range: 1…10 bar; switching differential: 0,05 ... 0,3 bar; max pressure: 16 bar
    https://honeywell.scene7.com/is/image/Honeywell65/hbt-bms-ex-pressure-switch-primaryimage
    EX-DNS16
    Pressure Switch with Stainless Steel Sensor to ATEX 201434EU, SPCO; differential not adjustable; setting range: 3…16 bar; switching differential: 0,05 ... 0,3 bar; max pressure: 25 bar
    https://honeywell.scene7.com/is/image/Honeywell65/hbt-bms-ex-pressure-switch-primaryimage
    EX-DNS16
    Pressure Switch with Stainless Steel Sensor to ATEX 201434EU, SPCO; differential not adjustable; setting range: 3…16 bar; switching differential: 0,05 ... 0,3 bar; max pressure: 25 bar
    https://honeywell.scene7.com/is/image/Honeywell65/hbt-bms-ex-pressure-switch-primaryimage
    EX-DNS16-S
    Pressure Switch with Stainless Steel Sensor to ATEX 201434EU, SPCO; differential not adjustable; setting range: 0,04…0,25 bar; switching differential: 20 ... 37 mbar; max pressure: 6 bar; with service function
    https://s7d1.scene7.com/is/image/Honeywell65/hbt-bms-ex-dns025-s-ex-dns-saftey-manual-pressure-switch-primaryimage
    EX-DNS16-S
    Pressure Switch with Stainless Steel Sensor to ATEX 201434EU, SPCO; differential not adjustable; setting range: 0,04…0,25 bar; switching differential: 20 ... 37 mbar; max pressure: 6 bar; with service function
    https://s7d1.scene7.com/is/image/Honeywell65/hbt-bms-ex-dns025-s-ex-dns-saftey-manual-pressure-switch-primaryimage
    EX-DNS3
    Pressure Switch with Stainless Steel Sensor to ATEX 201434EU, SPCO; differential not adjustable; setting range: 0,2…2,5 bar; switching differential: 10 ... 90 mbar; max pressure: 16 bar
    https://honeywell.scene7.com/is/image/Honeywell65/hbt-bms-ex-pressure-switch-primaryimage
    EX-DNS3
    Pressure Switch with Stainless Steel Sensor to ATEX 201434EU, SPCO; differential not adjustable; setting range: 0,2…2,5 bar; switching differential: 10 ... 90 mbar; max pressure: 16 bar
    https://honeywell.scene7.com/is/image/Honeywell65/hbt-bms-ex-pressure-switch-primaryimage
    EX-DNS6
    Pressure Switch with Stainless Steel Sensor to ATEX 201434EU, SPCO; differential not adjustable; setting range: 0,5…6 bar; switching differential: 0,05 ... 0,2 bar; max pressure: 16 bar
    https://honeywell.scene7.com/is/image/Honeywell65/hbt-bms-ex-dns6-ex-pressure-switch-aggressive-media-primaryimage
    EX-DNS6
    Pressure Switch with Stainless Steel Sensor to ATEX 201434EU, SPCO; differential not adjustable; setting range: 0,5…6 bar; switching differential: 0,05 ... 0,2 bar; max pressure: 16 bar
    https://honeywell.scene7.com/is/image/Honeywell65/hbt-bms-ex-dns6-ex-pressure-switch-aggressive-media-primaryimage
    EX-VNS111
    Vacuum Pressure Switch to ATEX 201434EU, SPCO; differential not adjustable; setting range: –1 …+0,1 bar; switching differential: 10 ... 65 mbar; max pressure: 6 bar
    https://honeywell.scene7.com/is/image/Honeywell65/hbt-bms-ex-vns111-ex-vns-mechanical-pressure-switch-primaryimage
    EX-VNS111
    Vacuum Pressure Switch to ATEX 201434EU, SPCO; differential not adjustable; setting range: –1 …+0,1 bar; switching differential: 10 ... 65 mbar; max pressure: 6 bar
    https://honeywell.scene7.com/is/image/Honeywell65/hbt-bms-ex-vns111-ex-vns-mechanical-pressure-switch-primaryimage