S20 20Nm Fail-Safe Spring Return Rotary Damper Actuator
The Honeywell spring return direct-coupled damper actuators provide modulating and floating control for air dampers, VAV units, Air handlers, Ventilation flaps, Louvers & reliable control for air damper applications.
Please sign in to access more documents
Once signed in, you may be able to access additional documents for your account.
The Honeywell spring return direct-coupled damper actuators provide modulating and floating control for air dampers, VAV units, Air handlers, Ventilation flaps, Louvers & reliable control for air damper applications with up to 1.5 m2 / 16 sq.ft (10 Nm / 88 lb-in) or 4.6 m2 / 50 sq.ft. (20 Nm / 177 lb-in) (Seal-less dampers; air friction dependent). Damper Actuators are easy to install with a self-centering shaft adapter that provides mounting flexibility and a greater clamping force. Detachable access cover allows direct wiring without a junction box, Stock less with the signal mode switch that adapts models to two-position, floating, or modulating applications. Direct-coupled damper actuators increased flexibility with select models available with/without three foot actuator whips & Sylk communications available on low-, medium- and high-torque DCAs.
Features & Benefits:- Self-centering shaft adapter
- Removable access cover
- Mechanical end limits (non-adjustable)
- Rotation direction selectable by choice of mounting orientation
- Mountable in any orientation (IP54 only when mounted on a horizontal shaft with access cover below the shaft)
- Mechanical position indicator
Others
- Maximum Storage Temperature
- 70 degree Celsius
- Minimum Storage Temperature
- -40 degree Celsius
- Minimum Operating Humidity
- 5 (Non-condensing) percentage relative humidity
- Maximum Operating Ambient Temperature
- 60 degree Celsius
- Minimum Operating Ambient Temperature
- -40 degree Celsius
- Maximum Operating Humidity
- 95 (Non-condensing) percentage relative humidity
Others
- Maximum Storage Temperature
- 70 degree Celsius
- Minimum Storage Temperature
- -40 degree Celsius
- Minimum Operating Humidity
- 5 (Non-condensing) percentage relative humidity
- Maximum Operating Ambient Temperature
- 60 degree Celsius
- Minimum Operating Ambient Temperature
- -40 degree Celsius
- Maximum Operating Humidity
- 95 (Non-condensing) percentage relative humidity
- Maximum Storage Temperature : 70 degree Celsius
- Minimum Storage Temperature : -40 degree Celsius
- Minimum Operating Humidity : 5 (Non-condensing) percentage relative humidity
- Maximum Operating Ambient Temperature : 60 degree Celsius
- Minimum Operating Ambient Temperature : -40 degree Celsius
- Maximum Operating Humidity : 95 (Non-condensing) percentage relative humidity