    The IQ4NC enables Trend networks on different media (either Ethernet, Trend current loop, or MS/TP) to be joined together in various configurations. It provides 4 virtual CNCs which allow supervisors or tools on the Ethernet network to connect to the Trend system.

    The IQ4NC/00 has no I/O channels, the IQ4NC/12 has 12, the IQ4NC/16/... and IQ4NC/32/have 16 I/O channels. External I/O modules enable the IQ4NC/32/... to be expanded to 32 I/O channels.

    Features & Benefits:
    • Trend system interface with MS/TP trunk (e.g. IQecos)
    • BACnet over MS/TP ? Extend Trend network from Ethernet to Trend current loop
    • BACnet over IP
    • Communication mode configuration facilitated by IQ web pages
    • INC alarm forwarding (e.g. enabling IQeco alarms to be forwarded to an IP address
    Specifications

    Others

    • Brand
      • Trend

    Others

    • Brand
      • Trend
    • Brand : Trend
    Name
    Date
    Size
    No Resources documents tagged to this product
    An error occurred . Please try after sometime

    _blank

    Communication_Technology@communication_technology|Maximum_Shipping_Storage_Temperature@maximum_shipping_storage_temperature

    Filters

    Product Number
    Part Number
    Compare
    Description
    Leaf Category
    Thumbnail
    Add to list
    IQ4NC-1040U501000
    IQ4NC1224-IQ4NC with 12 IO channels with 24 Vac supply Datasheet TA201288
    https://honeywell.scene7.com/is/image/Honeywell65/hbt-bms-iq4nc-controllers-primaryimage
    IQ4NC-1040U501000
    IQ4NC1224-IQ4NC with 12 IO channels with 24 Vac supply Datasheet TA201288
    https://honeywell.scene7.com/is/image/Honeywell65/hbt-bms-iq4nc-controllers-primaryimage
    IQ4NC-1040U501200
    IQ4NC12INT24VAC-IQ4NC with 12 IO channels and IQ Interfacing (24Vac)
    https://honeywell.scene7.com/is/image/Honeywell65/hbt-bms-IQ4NC-1040U801000
    IQ4NC-1040U501200
    IQ4NC12INT24VAC-IQ4NC with 12 IO channels and IQ Interfacing (24Vac)
    https://honeywell.scene7.com/is/image/Honeywell65/hbt-bms-IQ4NC-1040U801000
    IQ4NC-1040U511000
    IQ4NC0024-IQ4NC with zero IO channels with 24 Vac supply Datasheet TA201287
    https://honeywell.scene7.com/is/image/Honeywell65/hbt-bms-iq4nc-controllers-primaryimage
    IQ4NC-1040U511000
    IQ4NC0024-IQ4NC with zero IO channels with 24 Vac supply Datasheet TA201287
    https://honeywell.scene7.com/is/image/Honeywell65/hbt-bms-iq4nc-controllers-primaryimage
    IQ4NC-1040U511200
    IQ4NC00INT24VAC-IQ4NC with zero IO channels and IQ Interfacing (24Vac)
    https://honeywell.scene7.com/is/image/Honeywell65/hbt-bms-IQ4NC-1040U801000
    IQ4NC-1040U511200
    IQ4NC00INT24VAC-IQ4NC with zero IO channels and IQ Interfacing (24Vac)
    https://honeywell.scene7.com/is/image/Honeywell65/hbt-bms-IQ4NC-1040U801000
    IQ4NC-1040U801000
    IQ4NC12230-IQ4NC with 12 IO channels with 230 Vac supply Datasheet TA201286
    https://honeywell.scene7.com/is/image/Honeywell65/hbt-bms-iq4nc-controllers-primaryimage
    IQ4NC-1040U801000
    IQ4NC12230-IQ4NC with 12 IO channels with 230 Vac supply Datasheet TA201286
    https://honeywell.scene7.com/is/image/Honeywell65/hbt-bms-iq4nc-controllers-primaryimage
    IQ4NC-1040U801200
    IQ4NC12INT230-IQ4NC with 12 IO channels, IQ interfacing and 230 Vac supply
    https://honeywell.scene7.com/is/image/Honeywell65/hbt-bms-IQ4NC-1040U801000
    IQ4NC-1040U801200
    IQ4NC12INT230-IQ4NC with 12 IO channels, IQ interfacing and 230 Vac supply
    https://honeywell.scene7.com/is/image/Honeywell65/hbt-bms-IQ4NC-1040U801000
    IQ4NC-1040U811000
    IQ4NC00230-IQ4NC with zero IO channels with 230 Vac supply Datasheet TA201285
    https://honeywell.scene7.com/is/image/Honeywell65/hbt-bms-IQ4NC-1040U801000
    IQ4NC-1040U811000
    IQ4NC00230-IQ4NC with zero IO channels with 230 Vac supply Datasheet TA201285
    https://honeywell.scene7.com/is/image/Honeywell65/hbt-bms-IQ4NC-1040U801000
    IQ4NC-1040U811200
    IQ4NC00INT230-IQ4NC with without inputs or outputs with IQ interfacing and 230 Vac supply
    https://honeywell.scene7.com/is/image/Honeywell65/hbt-bms-iq4nc-controllers-primaryimage
    IQ4NC-1040U811200
    IQ4NC00INT230-IQ4NC with without inputs or outputs with IQ interfacing and 230 Vac supply
    https://honeywell.scene7.com/is/image/Honeywell65/hbt-bms-iq4nc-controllers-primaryimage
    IQ4NC-2040U531100
    IQ4NC16XNC24VAC-IQ4NC with 16 IO channels, XNC functionality and 24Vac supply Datasheet TA201285
    https://honeywell.scene7.com/is/image/Honeywell65/hbt-bms-iq4nc-controllers-primaryimage
    IQ4NC-2040U531100
    IQ4NC16XNC24VAC-IQ4NC with 16 IO channels, XNC functionality and 24Vac supply Datasheet TA201285
    https://honeywell.scene7.com/is/image/Honeywell65/hbt-bms-iq4nc-controllers-primaryimage
    IQ4NC-2040U541100
    IQ4NC32XNC24VAC-IQ4NC with 16 IO channels (expandable to 32), XNC functionality and 24Vac supply Datasheet TA201285
    https://honeywell.scene7.com/is/image/Honeywell65/hbt-bms-iq4nc-controllers-primaryimage
    IQ4NC-2040U541100
    IQ4NC32XNC24VAC-IQ4NC with 16 IO channels (expandable to 32), XNC functionality and 24Vac supply Datasheet TA201285
    https://honeywell.scene7.com/is/image/Honeywell65/hbt-bms-iq4nc-controllers-primaryimage