The printer is used with the Gamewell-FCI fire alarm control panels (FACPs) and provides printer capability to produce a written record of system events and status changes.
302 Series rate-anticipation heat detectors operate within a controlled range of two to three degrees of their setpoints, regardless of the rate of temperature rise. These detectors are available in either 135 °F (57.2 °C) or 194 °F (90 °C) ratings.
4XZM zone relay modules provide four Form C relay contacts to fire alarm control panels (FACPs).
4X™F transmitter modules provide output for local energy municipal box transmitters, and alarm and trouble reverse polarity circuits. The modules include a disable switch and disable trouble LED.
5600 Series mechanical heat detectors offer property protection against fire and are intended for non-life-safety installations where smoke detectors are inappropriate.
5820XL LED I/O driver modules provide an effective means to customize your remote annunciation. They provide LED annunciation and control inputs for the fire alarm control panel (FACP).
6500-MMK multi-mounting kits allow 6500 beam smoke detectors to be mounted to ceilings or to walls where the detector and reflector cannot be mounted within 10° of one another.
6500-SMK surface-mount kits are intended for use with beam detectors to mount transmitters and receivers when using 6500-MMK multi-mounting kits.
ANN-MBRLY mounting brackets are for use with NOTIFIER® NFW2-100 fire alarm control panel (FACP) applications.
AP-P adapter plates are decorative plastic adapters for mounting 302 Series detectors to four-inch outlet boxes.
RF-FTX Additional filter accessories are used for HPX-751E HARSH ™ analog addressable aspiration detectors.
Anti Condensation Film is an easy applicable film that provide long time resistance to condensation on the acrylic Emitter lens
Anti-Condensation Film is used for OSID-EH housings. An easy applicable film that provide long time resistance to condensation on the glass fronts.
Aspirated Gas Detection for Micro Bore ASD System (VESDA-E VEA Addressable Aspirating Smoke Detection) and When used with the VESDA-E VEA.
B110LP detector bases are designed for use with System Sensor® models 2151 photoelectronic and 1151 ionization detector heads. These 2-wire bases are equipped with screw terminals for power, ground, and an optional remote annunciator.
B112LP detector bases are designed for use with System Sensor® models 2151 photoelectronic and 1151 ionization detector heads. These 4-wire bases are equipped with screw terminals for power, ground, and an optional remote annunciator.
B114LP bases are for use with System Sensor® photoelectronic detector heads. They are intended for use in 4-wire systems with terminals provided for remote annunciator and relay connections.
B116LP bases are plug-in bases for use with System Sensor® ionization detector heads and System Sensor photoelectronic detector heads.
BAT Series batteries are Power-Sonic brand batteries. BAT series (or Power-Sonic brand) batteries are recommended for secondary power or backup power for all NOTIFIER® fire alarm control equipment.
Heating kits for use to prevent condensation with the BEAM1224 conventional beam smoke detectors. They lessen the likelihood of condensation by maintaining the unit at a temperature that is slightly higher than the surrounding air.
BEAMLRK long-range kits are designed for use with System Sensor® reflective projected beam smoke detectors and allow installation between 230 to 380 ft (70 to 100 m) apart.
BEAMMMK multi-mounting kits allow reflectors and reflected beam detectors to be mounted to either vertical walls or ceilings.
Backboxes are for use with fire alarm control panels (FACPs) and are used to mount up to two batteries and power supplies.
The Blanking Baffle is used with ICAM IAS aspirating smoke detector.
CAC-4 Class A converters are for use with Gamewell-FCI® Flex 404 4-zone fire alarm control panels (FACPs).
CB500 wiring barriers are used to separate power-limited and nonpower-limited wiring inside of junction boxes.
Battery charger circuit board and mounting chassis are designed for use with fire alarm control panels (FACPs).
CHS-4L chassis are for use with NOTIFIER® fire alarm control panels (FACPs). They are low-profile, 4-position chassis and mount two AA-30 amplifiers.
CO detector replacement plate to cover the footprint of previ