/content/hbtbt/ae/en/search-results.html

Manual Call Points/Pull Stations

MCP5A Indoor Callpoint

The MCP5A product has the Advanced Protocol embedded. A version of this call point with built in isolation is also available.

Overview

Installation efficiency, flexibility and full compliance with the latest standards are at the heart of the new MCP Indoor Call Point range. Installation time and ultimately cost, are of paramount importance to any fire or security installer. The MCP5A product has the Advanced Protocol embedded. A version of this call point with built in isolation is also available. The MCP range directly reflects this need by providing a unique ‘plug and play’ concept designed specifically to reduce installation time. All new MCP products utilize a special terminal block, where all initial installation cabling is terminated. This terminal block is then simply connected to the back of the MCP. Simple, but effective with no re-termination required and no time wasted.

Features & Benefits:
  • Unique ‘Plug & Play’ installation concept
  • Total ‘Flex-Ability’ in the choice of operating element
  • Anti-Tamper facility
  • Enhanced aesthetics
  • Backward compatibility
Certifications:
  • EN54
  • LPCB
  • VDS
  • CPD
Specifications

Others

  • Brand
    • Esser
    • Honeywell BMS EMEA
    • KAC
    • Morley-IAS
    • NOTIFIER
    • Notifier
    • System Sensor

Others

  • Brand
    • Esser
    • Honeywell BMS EMEA
    • KAC
    • Morley-IAS
    • NOTIFIER
    • Notifier
    • System Sensor
  • Brand : Esser|Honeywell BMS EMEA|KAC|Morley-IAS|NOTIFIER|Notifier|System Sensor
Others
Name
Description
File Size
Date
Size
Indoor Surface-Flush Mounting Addressable Call Point With Short Circuit Isolator Advanced Protocol-Certificate of Conformance
application/pdf 198.1 KB
6/1/2023
198.1 KB
Sistemas Analógicos Catalog
application/pdf 839.05 KB
839.05 KB
M5A PULSADOR MANUAL PARA INTERIORES Data Sheet
application/pdf 289.56 KB
5/1/2023
289.56 KB
Pulsante Manuale Indirizzabili-Declaration of Performance
application/pdf 830.99 KB
830.99 KB
Pulsanti Indirizzati-Data Sheet
application/pdf 585.53 KB
6/1/2023
585.53 KB
Analogue Call Point-Data Sheet
application/pdf 583.57 KB
6/1/2023
583.57 KB
Name
Description
File Size
Date
Size
Indoor Surface-Flush Mounting Addressable Call Point With Short Circuit Isolator Advanced Protocol-Certificate of Conformance
198.1 KB
6/1/2023
198.1 KB
Sistemas Analógicos Catalog
839.05 KB
839.05 KB
M5A PULSADOR MANUAL PARA INTERIORES Data Sheet
289.56 KB
5/1/2023
289.56 KB
Pulsante Manuale Indirizzabili-Declaration of Performance
830.99 KB
830.99 KB
Pulsanti Indirizzati-Data Sheet
585.53 KB
6/1/2023
585.53 KB
Analogue Call Point-Data Sheet
583.57 KB
6/1/2023
583.57 KB
Name
Description
File Size
Date
Size
Indoor Surface-Flush Mounting Addressable Call Point With Short Circuit Isolator Advanced Protocol-Certificate of Conformance
198.1 KB
6/1/2023
Sistemas Analógicos Catalog
839.05 KB
M5A PULSADOR MANUAL PARA INTERIORES Data Sheet
289.56 KB
5/1/2023
Pulsante Manuale Indirizzabili-Declaration of Performance
830.99 KB
Pulsanti Indirizzati-Data Sheet
585.53 KB
6/1/2023
Analogue Call Point-Data Sheet
583.57 KB
6/1/2023
Product Number
Image
SKU
Description
alt
M5A-RP01FG-N026-01
M700KAC-FG
alt
M5A-RP02FG-N026-01
M700KACI-FG Addressable Call Point with in-built Isolator (Replacement for M700KACI-FG)
alt
M5A-RP02SG-N026-01
M700KACI-SG Addressable Call Point with in-built Isolator
alt
M5A-RP03FG-K013-01
Indoor Callpoint, MCP5A, Honeywell Protocol, No Isolation, 30V DC, Red, Flush Mount, Glass
alt
M5A-RP03SF-N026-03
HONEYWELL PROTOCOL-NON ISO-FE1140-F222
alt
M5A-RP03SG-K013-01
HONEYWELL PROTOCOL-NON ISO-GL1140-F222
alt
M5A-RP05FF-K013-01
Addressable manual call point. Flexible element included. Requires SR1T for surface mounting or a single gang backbox for flush mounting.
alt
M5A-RP05FG-K013-01
Indoor Callpoint, MCP5A, No Isolation, Addressable, Red, Flush Mount, Glass
alt
M5A-RP06FF-K013-01
Addressable manual call point with built in isolato. Flexible element included. Requires SR1T for surface mounting or a single gang backbox for flush mounting.
alt
M5A-RP06FG-K013-01
Indoor Callpoint, MCP5A, Isolation, Addressable, Red, Flush Mount, Glass
Image
SKU
Description
alt
M5A-RP01FG-N026-01
M700KAC-FG
alt
M5A-RP02FG-N026-01
M700KACI-FG Addressable Call Point with in-built Isolator (Replacement for M700KACI-FG)
alt
M5A-RP02SG-N026-01
M700KACI-SG Addressable Call Point with in-built Isolator
alt
M5A-RP03FG-K013-01
Indoor Callpoint, MCP5A, Honeywell Protocol, No Isolation, 30V DC, Red, Flush Mount, Glass
alt
M5A-RP03SF-N026-03
HONEYWELL PROTOCOL-NON ISO-FE1140-F222
alt
M5A-RP03SG-K013-01
HONEYWELL PROTOCOL-NON ISO-GL1140-F222
alt
M5A-RP05FF-K013-01
Addressable manual call point. Flexible element included. Requires SR1T for surface mounting or a single gang backbox for flush mounting.
alt
M5A-RP05FG-K013-01
Indoor Callpoint, MCP5A, No Isolation, Addressable, Red, Flush Mount, Glass
alt
M5A-RP06FF-K013-01
Addressable manual call point with built in isolato. Flexible element included. Requires SR1T for surface mounting or a single gang backbox for flush mounting.
alt
M5A-RP06FG-K013-01
Indoor Callpoint, MCP5A, Isolation, Addressable, Red, Flush Mount, Glass