/content/hbtbt/au/en/search-results.html

    Zone & Unitary Controllers

    Honeywell Optimizer VAV Controller

    Honeywell’s Optimizer VAV Controller is a programmableroom controller with integrated actuator and air flow sensor.

    Overview
    "Honeywell’s Optimizer VAV Controller is a programmable room controller with integrated actuator and air flow sensor. As a freely programmable VAV controller with universal IOs, this VAV controller has configuration flexibility to achieve a variety of specific applications. Smart engineering and commissioning tools with Honeywell Optimizer Workbench and a mobile application for test and balance make installation cost effective.Spyder™ Model 7 offers BACnet / IP or BACnet / MSTP, Sylk™ bus technology, Modbus RTU RS-485, universal inputs, analog outputs, and solid-state relays.""Supports BACnet IP or BACnet MSTP bus for communicationBACnet IP enables faster download, thereby reducing commissioning time, and increased data bandwidth for increased data sharing compared to traditional BACnet MSTP communicationBACnet IP variants supports: IPv4 addressing, DHCP and Link Local addressing modes, and connection speed: 10/100 MbpsModbus master for integration purposes and automatic addressing functionalitySylk™ bus two-wire polarity insensitive interface connects to Honeywell Sylk™ wall modules without using physical I/O pointsIntegrated BLE (Bluetooth)Freely programmable in Honeywell Optimizer SupervisorCompact design for small enclosures and easy to install on round ductsColor-coded, removable terminal blocks to simplify wiring and replacementReal-time clock, a supercapacitor for 24-hour data retention24 VAC power supply, 20 VDC at 75 mA auxiliary supply for field devicesSeven universal inputs/outputs usable as analog voltage/current output or as a universal/binary inputFive 24 VAC solid state relay outputs with 1.5 A continuous and 3.5 A in-rush for 100 ms per SSR outputFeatures a non-isolated RS-485 interface for Modbus communicationIntegrated 44 in-lbs (5 Nm) actuator with 90 sec runtime at 60 Hz (108 sec at 50 Hz) with position feedbackField replaceable differential pressure sensor (± 500 Pa,accuracy +/- 3 % of full range)Mobile app for VAV balancing with easy access to the controller via Bluetooth integrated in the controller""CEBACnet BTL®-Listed,IP VAV model as BACnet Building Controller (B-BC) and MSTP VAV model as BACnet Advanced Application Controller (B-AAC),(BTL certification in process)UL916, Energy Management EquipmentFCC Part 15, Class AEN 55022. Class AEN 61000-3-2, 61000UL2043"