/content/hbtbt/au/en/search-results.html

Monitors

300 Series Monitor Module

Monitor Modules are intended for use in intelligent, two-wire systems where the individual address of each module is selected using the built-in rotary switches. They offer either two-wire or four-wire fault-tolerant Initiating Device Circuit (IDC).

Overview

Monitor Modules use to monitor a zone of four-wire smoke detectors, manual fire alarm pull stations, water flow devices, or other normally open dry-contact alarm activation devices. They are used to monitor normally-open supervisory devices with special supervisory indication at the control panel. Monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the Style B circuit.

Features & Benefits:
  • Built-in type identification automatically identifies this device as a monitor module to the control panel
  • Powered directly by two-wire SLC loop. No additional power required
  • High noise (EMF/RFI) immunity
  • SEMS screws with clamping plates for ease of wiring
  • LED flashes green during normal operation and latches on steady red to indicate alarm
Certifications:
  • UL: S1570
  • ULC: S1570
  • FM Approved
  • CSFM: 7300-0554:131
  • MEA: 130-00-E
  • FDNY: COA
Others
Name
Description
File Size
Date
Size
M300, M301 monitor modules, I300 isolator module and Model C300 and C304 control modules Listing
application/pdf 165.09 KB
5/14/2023
165.09 KB
MS-9200 Details (cabinet, modules, etc) Drawing
image/vnd.dwg 130.37 KB
4/28/2023
130.37 KB
MS-9200 Details (cabinet, modules, etc) Drawing
image/vnd.dwg 130.37 KB
4/28/2023
130.37 KB
ISO-6 UL Listing
application/pdf 175.39 KB
5/14/2023
175.39 KB
Brochure
Name
Description
File Size
Date
Size
Isolator Load Rating Table Brochure
application/pdf 38.09 KB
8/9/2023
38.09 KB
Manuals and Guides
Name
Description
File Size
Date
Size
M300(A) Monitor Module, C304(A) Control Module, & I300(A)
application/pdf 207.1 KB
5/11/2023
207.1 KB
New Addressable Devices & Detector Sensitivity Supplement
application/pdf 39.96 KB
5/11/2023
39.96 KB
Fire-Lite SLC Wiring Manual
application/pdf 2.92 MB
1/11/2024
2.92 MB
Name
Description
File Size
Date
Size
Isolator Load Rating Table Brochure
38.09 KB
8/9/2023
38.09 KB
M300, M301 monitor modules, I300 isolator module and Model C300 and C304 control modules Listing
165.09 KB
5/14/2023
165.09 KB
M300(A) Monitor Module, C304(A) Control Module, & I300(A)
207.1 KB
5/11/2023
207.1 KB
MS-9200 Details (cabinet, modules, etc) Drawing
130.37 KB
4/28/2023
130.37 KB
MS-9200 Details (cabinet, modules, etc) Drawing
130.37 KB
4/28/2023
130.37 KB
New Addressable Devices & Detector Sensitivity Supplement
39.96 KB
5/11/2023
39.96 KB
Fire-Lite SLC Wiring Manual
2.92 MB
1/11/2024
2.92 MB
ISO-6 UL Listing
175.39 KB
5/14/2023
175.39 KB
Name
Description
File Size
Date
Size
M300, M301 monitor modules, I300 isolator module and Model C300 and C304 control modules Listing
165.09 KB
5/14/2023
MS-9200 Details (cabinet, modules, etc) Drawing
130.37 KB
4/28/2023
MS-9200 Details (cabinet, modules, etc) Drawing
130.37 KB
4/28/2023
ISO-6 UL Listing
175.39 KB
5/14/2023
Isolator Load Rating Table Brochure
38.09 KB
8/9/2023
M300(A) Monitor Module, C304(A) Control Module, & I300(A)
207.1 KB
5/11/2023
New Addressable Devices & Detector Sensitivity Supplement
39.96 KB
5/11/2023
Fire-Lite SLC Wiring Manual
2.92 MB
1/11/2024