    SK-Control-6 Six Circuit Supervised Control Module

    SK-Control-6 six circuit supervised control module provides supervised monitoring of wiring to load devices that require an external power supply or amplifier to operate.

    Overview

    SK-Control-6 six circuit supervised control modulesare for use with Silent Knight® IntelliKnight® series fire alarm control panels (FACPs). SK-Control-6 six circuit supervised control modulesprovide supervised monitoring of wiring to load devices that require an external power supply or amplifier to operate, such as bells, horns, and strobes. They are capable of supporting Class B (Style Y) and Class A (Style Z) wiring. Upon command from the FACP, SK-Control-6 modules will disconnect the supervision and connect the external power supply across the load device. The disconnection of the supervision provides a positive indication to the panel that the control relay actually turned on. The external power supply is always relay isolated from thesignaling line circuit (SLC) loop, so that a trouble condition on the power supply will never interfere with the rest of the system. If needed, you can disable a maximum of three unused modules on the SK-Control-6 board. Each module has terminals for connection to an external supply circuit for powering devices on its notification appliance circuit (NAC). One or more multiple power supplies or amplifiers can be used. SK-Control-6 six circuit supervised control moduleshave a short circuit protection monitor for each module. The short circuit protection monitor protects external power supplies against short circuit conditions on the NAC. In addition, an algorithm is incorporated to find a short when the module is active. The module will close all circuits that are not shorted to find the NAC with the problem.

    Features & Benefits:
    • Flexible solution for adding notification circuits where needed
    • Removable 12 to 18 AWG plug-in terminal blocks
    • Support for Class B or Class A wiring
    • Individual LED for each module
    • Two module mounting in the IDP-ACB cabinet
    • Unused modules can be disabled
    • Rotary address switches for fast installation
    • Mounting hardware included
    Certifications:
    • UL Listed
    Specifications

    Others

    • Brand
      • Silent Knight

    Others

    • Brand
      • Silent Knight
    • Brand : Silent Knight
    Others
    Name
    Description
    File Size
    Date
    Size
    SK-CONTROL-6 BIM File
    application/x-tika-msoffice 364 KB
    10/3/2024
    364 KB
    SK-Control Addressable Notification Module-Installation Manual
    application/pdf 959.97 KB
    10/3/2024
    959.97 KB
    IDP-ACB Install Sheet
    application/pdf 24.18 KB
    10/3/2024
    24.18 KB
    IDP-Zone Addressable Zone Interface Module Fire Listing
    application/pdf 176.82 KB
    10/3/2024
    176.82 KB
    Sales Sheet
    Name
    Description
    File Size
    Date
    Size
    IntelliKnight System Sensor Device Sell Sheet
    application/pdf 210.82 KB
    10/3/2024
    210.82 KB
    Brochure
    Name
    Description
    File Size
    Date
    Size
    Isolator Load Rating Table Brochure
    application/pdf 55.33 KB
    1/1/2016
    55.33 KB
    Installation Instructions
    Name
    Description
    File Size
    Date
    Size
    SK-Control Addressable Notification Module Manual
    application/pdf 1.05 MB
    10/3/2024
    1.05 MB
    SK-Control-6 Six Circuit Notification Module Manual
    application/pdf 1015.83 KB
    10/3/2024
    1015.83 KB
    Data Sheet
    Name
    Description
    File Size
    Date
    Size
    SK-Control-6 Six Circuit Notification Module Data Sheet
    application/pdf 132.91 KB
    11/1/2017
    132.91 KB
    IntelliKnight System Sensor Device Specification Data Sheet
    application/pdf 211.15 KB
    9/10/2024
    211.15 KB
    Name
    Description
    File Size
    Date
    Size
    Isolator Load Rating Table Brochure
    application/pdf 55.33 KB
    1/1/2016
    55.33 KB
    SK-CONTROL-6 BIM File
    application/x-tika-msoffice 364 KB
    10/3/2024
    364 KB
    SK-Control Addressable Notification Module-Installation Manual
    application/pdf 959.97 KB
    10/3/2024
    959.97 KB
    IDP-ACB Install Sheet
    application/pdf 24.18 KB
    10/3/2024
    24.18 KB
    IDP-Zone Addressable Zone Interface Module Fire Listing
    application/pdf 176.82 KB
    10/3/2024
    176.82 KB
    IntelliKnight System Sensor Device Sell Sheet
    application/pdf 210.82 KB
    10/3/2024
    210.82 KB
    SK-Control-6 Six Circuit Notification Module Data Sheet
    application/pdf 132.91 KB
    11/1/2017
    132.91 KB
    SK-Control Addressable Notification Module Manual
    application/pdf 1.05 MB
    10/3/2024
    1.05 MB
    IntelliKnight System Sensor Device Specification Data Sheet
    application/pdf 211.15 KB
    9/10/2024
    211.15 KB
    SK-Control-6 Six Circuit Notification Module Manual
    application/pdf 1015.83 KB
    10/3/2024
    1015.83 KB
    Name
    Description
    File Size
    Date
    Size
    SK-CONTROL-6 BIM File
    364 KB
    10/3/2024
    SK-Control Addressable Notification Module-Installation Manual
    959.97 KB
    10/3/2024
    IDP-ACB Install Sheet
    24.18 KB
    10/3/2024
    IDP-Zone Addressable Zone Interface Module Fire Listing
    176.82 KB
    10/3/2024
    IntelliKnight System Sensor Device Sell Sheet
    210.82 KB
    10/3/2024
    Isolator Load Rating Table Brochure
    55.33 KB
    1/1/2016
    SK-Control Addressable Notification Module Manual
    1.05 MB
    10/3/2024
    SK-Control-6 Six Circuit Notification Module Manual
    1015.83 KB
    10/3/2024
    SK-Control-6 Six Circuit Notification Module Data Sheet
    132.91 KB
    11/1/2017
    IntelliKnight System Sensor Device Specification Data Sheet
    211.15 KB
    9/10/2024
    Part Number
    Description
    Leaf Category
    Thumbnail
    Add to list