/content/hbtbt/au/en/search-results.html

Zone Modules

Conventional Zone Interface Device

Conventional zone interface devices are designed as the interface between the 600 Series and ILI95-E3 Series® fire alarm control panel's (FACPs) analog circuits and normally open contact devices or conventional smoke detectors.

Overview

Conventional zone interface devices are designed as the interface between the 600 Series and ILI95-E3 Series® fire alarm control panel's (FACPs) analog circuits and normally open contact devices or conventional smoke detectors. Conventional zone interface devices monitor up to 25 conventional detectors. You can use conventional zone interface devices with Style B, C, D, or E wiring.

Conventional zone interface devices can monitor up to 25 conventional smoke detectors via a 3-wire circuit. Conventional zone interface devices act as a remotely located conventional zone. They provide a supervised circuit to connect to conventional-type devices such as smoke detectors or contact devices. If any detector on the device's circuit goes into alarm, it will report its own address to the main control panel via the analog circuit, and the FACP will initiate the programmed response. The LEDs on the conventional detector and conventional zone interface devices will both light, indicating that the devices are in alarm.

If trouble is detected on the monitored circuit, the conventional zone interface devices will report the trouble condition to the FACP. Conventional zone interface devices will detect trouble from either the field wiring or a connected device. Conventional zone interface devices can be either surface- or flush-mounted and include an LED for annunciation. Conventional zone interface devices mount in a standard 4x4.688 inch (10.16x11.908 cm) or double-gang electrical backbox. They should be mounted in an easily accessible location, so that the built-in LED indicators may be easily seen and display the proper connection and device activation.

Features & Benefits:
  • Provides an LED for alarm annunciation
  • Uses either surface- or flush-mounted
  • Field-programmable
  • Contains screw terminals for field-wiring connections
Certifications:
  • UL Listed: S521
  • FM Approved
  • FDNY: Approved
  • CSFM: 7300-1703:0135
  • ISO 9001 Certification
Others
Name
Description
File Size
Date
Size
E3 Series A and E Specification - Stand Alone (DOCX)
application/vnd.openxmlformats-officedocument.wordprocessingml.document 86.29 KB
8/1/2023
86.29 KB
E3 Series A and E Specification - Stand Alone (PDF)
application/pdf 353.47 KB
8/1/2023
353.47 KB
E3 Series A and E Specification - Network (PDF)
application/pdf 356.91 KB
8/1/2023
356.91 KB
E3 Series A and E Specification - Voice (PDF)
application/pdf 421.32 KB
8/1/2023
421.32 KB
E3 Series A and E Specification - Voice (DOCX)
application/vnd.openxmlformats-officedocument.wordprocessingml.document 78.49 KB
6/16/2023
78.49 KB
E3 Series A and E Specification - Network (DOCX)
application/vnd.openxmlformats-officedocument.wordprocessingml.document 84.55 KB
8/1/2023
84.55 KB
Engineering Specifications
Name
Description
File Size
Date
Size
610 Network Specification
application/msword 147.5 KB
5/14/2023
147.5 KB
632 Network Specification
application/msword 147.5 KB
5/14/2023
147.5 KB
IdentiFlex 602 SmartScan AandE Specification
application/msword 129.5 KB
5/14/2023
129.5 KB
610 Stand Alone Specification
application/msword 243.5 KB
5/14/2023
243.5 KB
650 Network Specification
application/msword 147 KB
5/14/2023
147 KB
602 Network Specification
application/msword 144 KB
5/14/2023
144 KB
Data Sheet
Name
Description
File Size
Date
Size
IdentiFlex 600 Series Input Interface Devices Data Sheet
application/pdf 253.55 KB
3/9/2023
253.55 KB
CZI-95 Conventional Zone Interface Data Sheet
application/pdf 61.42 KB
5/14/2023
61.42 KB
Catalog
Name
Description
File Size
Date
Size
Engineering and Applications Catalog
application/pdf 131.74 KB
5/10/2023
131.74 KB
Name
Description
File Size
Date
Size
E3 Series A and E Specification - Stand Alone (DOCX)
86.29 KB
8/1/2023
86.29 KB
610 Network Specification
147.5 KB
5/14/2023
147.5 KB
632 Network Specification
147.5 KB
5/14/2023
147.5 KB
IdentiFlex 602 SmartScan AandE Specification
129.5 KB
5/14/2023
129.5 KB
610 Stand Alone Specification
243.5 KB
5/14/2023
243.5 KB
650 Network Specification
147 KB
5/14/2023
147 KB
602 Network Specification
144 KB
5/14/2023
144 KB
Engineering and Applications Catalog
131.74 KB
5/10/2023
131.74 KB
IdentiFlex 600 Series Input Interface Devices Data Sheet
253.55 KB
3/9/2023
253.55 KB
CZI-95 Conventional Zone Interface Data Sheet
61.42 KB
5/14/2023
61.42 KB
E3 Series A and E Specification - Stand Alone (PDF)
353.47 KB
8/1/2023
353.47 KB
E3 Series A and E Specification - Network (PDF)
356.91 KB
8/1/2023
356.91 KB
E3 Series A and E Specification - Voice (PDF)
421.32 KB
8/1/2023
421.32 KB
E3 Series A and E Specification - Voice (DOCX)
78.49 KB
6/16/2023
78.49 KB
E3 Series A and E Specification - Network (DOCX)
84.55 KB
8/1/2023
84.55 KB
Name
Description
File Size
Date
Size
E3 Series A and E Specification - Stand Alone (DOCX)
86.29 KB
8/1/2023
E3 Series A and E Specification - Stand Alone (PDF)
353.47 KB
8/1/2023
E3 Series A and E Specification - Network (PDF)
356.91 KB
8/1/2023
E3 Series A and E Specification - Voice (PDF)
421.32 KB
8/1/2023
E3 Series A and E Specification - Voice (DOCX)
78.49 KB
6/16/2023
E3 Series A and E Specification - Network (DOCX)
84.55 KB
8/1/2023
610 Network Specification
147.5 KB
5/14/2023
632 Network Specification
147.5 KB
5/14/2023
IdentiFlex 602 SmartScan AandE Specification
129.5 KB
5/14/2023
610 Stand Alone Specification
243.5 KB
5/14/2023
650 Network Specification
147 KB
5/14/2023
602 Network Specification
144 KB
5/14/2023
IdentiFlex 600 Series Input Interface Devices Data Sheet
253.55 KB
3/9/2023
CZI-95 Conventional Zone Interface Data Sheet
61.42 KB
5/14/2023
Engineering and Applications Catalog
131.74 KB
5/10/2023