/content/hbtbt/au/en/search-results.html

Flow Switches & Sensors

SWL Air flow monitoring

The SLF... sensor can be used in combination with an ASL… evaluation device to monitor the flow in the air (e.g. in air-conditioning systems). The switching point is adjustable.

Overview

The SLF... sensor can be used in combination with an ASL… evaluation device to monitor the flow in the air (e.g. in air-conditioning systems). The switching point is adjustable. While the fan starts up the switch-on bypass is active. The bypass duration (2 – 60 s) is adjustable.The air flow monitors work according to the calorimetric principle. A thermistor is heated up. As heat is withdrawn by the flowing air, the thermistor resistance alters. The change in resistance is evaluated. As the resistance also depends on the temperature of the medium, the difference must be determined by a second thermistor. The difference is compensated and in this way the switching point is kept stable.Suspended materials adhering to the sensor can have an insulating effect and so affect themeasurement result and hence the defined switching point. Therefore it is advisable to remove any dirt during routine maintenance operations.

Specifications

Others

  • Minimum Setpoint Velocity
    • 0.1 m/s cubic metre per hour
  • Mounting Type
    • Universal inch
    • Universal inch
  • Brand
    • Honeywell BMS EMEA
  • Switch Configuration
    • Evaluation unit: relay SPST 8A, 250 VAC, switchpoint adjustable from 0,1..20 m/s air speed
    • Evaluation unit: relay SPST 8A, 250 VAC, switchpoint adjustable from 0,1..20 m/s air speed
  • Maximum Setpoint Velocity
    • 20 m/s cubic metre per hour

Others

  • Minimum Setpoint Velocity
    • 0.1 m/s cubic metre per hour
  • Mounting Type
    • Universal inch
    • Universal inch
  • Brand
    • Honeywell BMS EMEA
  • Switch Configuration
    • Evaluation unit: relay SPST 8A, 250 VAC, switchpoint adjustable from 0,1..20 m/s air speed
    • Evaluation unit: relay SPST 8A, 250 VAC, switchpoint adjustable from 0,1..20 m/s air speed
  • Maximum Setpoint Velocity
    • 20 m/s cubic metre per hour
  • Minimum Setpoint Velocity : 0.1 m/s cubic metre per hour
  • Mounting Type : Universal inch|Universal inch
  • Brand : Honeywell BMS EMEA
  • Switch Configuration : Evaluation unit: relay SPST 8A, 250 VAC, switchpoint adjustable from 0,1..20 m/s air speed|Evaluation unit: relay SPST 8A, 250 VAC, switchpoint adjustable from 0,1..20 m/s air speed
  • Maximum Setpoint Velocity : 20 m/s cubic metre per hour
Others
Name
Description
File Size
Date
Size
SWL Air flow monitoring
application/pdf 130.62 KB
5/14/2023
130.62 KB
Luftstromüberwachung Montage- und Bedienungsanleitung
application/pdf 179.4 KB
5/11/2023
179.4 KB
SWL Luftstromüberwachung
application/pdf 130.71 KB
4/5/2023
130.71 KB
Electronic flow switch series
application/pdf 237.01 KB
5/14/2023
237.01 KB
Name
Description
File Size
Date
Size
SWL Air flow monitoring
application/pdf 130.62 KB
5/14/2023
130.62 KB
Luftstromüberwachung Montage- und Bedienungsanleitung
application/pdf 179.4 KB
5/11/2023
179.4 KB
SWL Luftstromüberwachung
application/pdf 130.71 KB
4/5/2023
130.71 KB
Electronic flow switch series
application/pdf 237.01 KB
5/14/2023
237.01 KB
Name
Description
File Size
Date
Size
SWL Air flow monitoring
130.62 KB
5/14/2023
Luftstromüberwachung Montage- und Bedienungsanleitung
179.4 KB
5/11/2023
SWL Luftstromüberwachung
130.71 KB
4/5/2023
Electronic flow switch series
237.01 KB
5/14/2023