Releasing Panels
Releasing Control Module
The Gamewell-FCI Releasing Control Modules are specifically designed for fire suppression releasing applications in the E3 Series System.
The Gamewell-FCI, Releasing Control Modules are specifically designed for fire suppression releasing applications in the E3 Series System. Power to the release agent solenoid(s) runs through this module to offer superior full-time monitoring and supervision. The Releasing Control Modules supervises the wiring to the connected load and reports the status to the panel as Normal, Open and Short Circuit. Releasing Control Modules Can power one 24V or two 12V solenoids and Mounts in a standard 4in (10.16 cm) junction box.
Features & Benefits:- Redundant protocol for added protection
- Configurable for Class A or Class B operation
- Supports external supply voltage monitoring
- Includes a panel controlled status LED
- Offers analog communications
- Uses rotary address switches
- Has a low standby current
- Provides the Velociti Series operation
- FM Approved
- ISO 9001 Certification
- UL Standard: UL 864 9th Edition
- UL: S1949
Others
- External Supply Voltage
- 24 DC volt
- Minimum Operating Voltage
- 15voltage direct current
- Maximum Operating Humidity
- 95Percentage
- Maximum Activation Current
- 2ampere
- Signaling Line Circuit Maximum Average Operating Current
- 700 µA
- Maximum Operating Voltage
- 32voltage direct current
- Standby Current
- 6.4milliampere
- Solenoid Supervisory Loop Voltage
- 3.3volt
- Solenoid Supervisory Loop Current
- 30milliampere
- Compatible Environments
- This system meets NFPA requirements for operation at 0 - 49°C/32 - 120°F and at a relative humidity 93% ± 2% (non-condensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 - 27°C/60 - 80°F.
- Wiring Configuration
- Class B
- Class A
- Signaling Line Circuit Maximum Activation Current
- 9milliampere
Others
- External Supply Voltage
- 24 DC volt
- Minimum Operating Voltage
- 15voltage direct current
- Maximum Operating Humidity
- 95Percentage
- Maximum Activation Current
- 2ampere
- Signaling Line Circuit Maximum Average Operating Current
- 700 µA
- Maximum Operating Voltage
- 32voltage direct current
- Standby Current
- 6.4milliampere
- Solenoid Supervisory Loop Voltage
- 3.3volt
- Solenoid Supervisory Loop Current
- 30milliampere
- Compatible Environments
- This system meets NFPA requirements for operation at 0 - 49°C/32 - 120°F and at a relative humidity 93% ± 2% (non-condensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 - 27°C/60 - 80°F.
- Wiring Configuration
- Class B
- Class A
- Signaling Line Circuit Maximum Activation Current
- 9milliampere
- Minimum Operating Voltage : 15voltage direct current
- Maximum Operating Humidity : 95Percentage
- Maximum Activation Current : 2ampere
- Signaling Line Circuit Maximum Average Operating Current : 700 µA
- Maximum Operating Voltage : 32voltage direct current
- Standby Current : 6.4milliampere
- Solenoid Supervisory Loop Voltage : 3.3volt
- Solenoid Supervisory Loop Current : 30milliampere
- Compatible Environments : This system meets NFPA requirements for operation at 0 - 49°C/32 - 120°F and at a relative humidity 93% ± 2% (non-condensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 - 27°C/60 - 80°F.
- Wiring Configuration : Class B|Class A
- Signaling Line Circuit Maximum Activation Current : 9milliampere
- External Supply Voltage : 24 DC volt