Parts & Accessories

Large Bore Gas Detector

The VESDA Sense point XCL- Large Bore is a gas detection solution that utilizes the ASD pipe network to deliver superior gas detection via multiple hole (multi-point) sampling.

The VESDA Sense point XCL- Large Bore is a gas detection solution that utilizes the ASD pipe network to deliver superior gas detection via multiple hole (multi-point) sampling. The combined solution provides reliable detection of gases for occupant protection and process monitoring whilst simultaneously ensuring protection against fire threats. The Large Bore portfolio has a range of gas sensors that addresses a wide range of applications and through its Bluetooth interface can be paired with a smart device for commissioning and maintenance. The smart device application (Sensepoint App) provides quick access to detector diagnostic information and simplifies detector configuration, calibration and bump testing.

Features & Benefits:
  • Wide range of gases to support most application
  • Aspirated gas sampling technology
  • Integral alarm status LEDs
  • Integral gas port for bump test and calibration
  • Field replaceable gas sensor cartridges
  • Smart device application (Sensepoint App) enables faster detector commissioning, maintenance and service
  • Multiple output options: 2 x configurable relays (Alarm, Fault), Analog 4-20mA or Modbus RTU
Certifications:
  • EN/UL/IEC 61010-1
  • CSA-C22.2 No. 61010-1-12
  • CE – EMC
  • EN 50270

Others

  • Overall Height
    • 113 millimetre
  • Overall Weight
    • 500 gram
  • Minimum Operating Ambient Temperature
    • −20 degree Celsius
  • Maximum Operating Ambient Temperature
    • 50 degree Celsius
  • Overall Width
    • 113 millimetre
  • Maximum Operating Humidity
    • 99 Percentage
  • Overall Depth
    • 59 millimetre
  • Minimum Operating Humidity
    • 0 Percentage
  • Regulatory Approvals
    • EN/UL/IEC 61010-1; CSA-C22.2 No. 61010-1-12; EN 50270; RED, FCC, BT SIG; UL2075 (CO and CH4); AS 1668.2
  • For Use With
    • BMS; fire alarm panels; PLCs; HVAC
  • Minimum Operating Pressure
    • 90kilopascal
  • Indicator LED
    • Integral alarm status LEDs
  • Maximum Operating Pressure
    • 110kilopascal
  • Includes
    • Main detector unit; Flow cap and elbows
  • Enclosure Rating
    • IP65; Type 4 (NEMA 250)
  • Operating Frequency Range
    • 50; 60hertz

Others

  • Overall Height
    • 113 millimetre
  • Overall Weight
    • 500 gram
  • Minimum Operating Ambient Temperature
    • −20 degree Celsius
  • Maximum Operating Ambient Temperature
    • 50 degree Celsius
  • Overall Width
    • 113 millimetre
  • Maximum Operating Humidity
    • 99 Percentage
  • Overall Depth
    • 59 millimetre
  • Minimum Operating Humidity
    • 0 Percentage
  • Regulatory Approvals
    • EN/UL/IEC 61010-1; CSA-C22.2 No. 61010-1-12; EN 50270; RED, FCC, BT SIG; UL2075 (CO and CH4); AS 1668.2
  • For Use With
    • BMS; fire alarm panels; PLCs; HVAC
  • Minimum Operating Pressure
    • 90kilopascal
  • Indicator LED
    • Integral alarm status LEDs
  • Maximum Operating Pressure
    • 110kilopascal
  • Includes
    • Main detector unit; Flow cap and elbows
  • Enclosure Rating
    • IP65; Type 4 (NEMA 250)
  • Operating Frequency Range
    • 50; 60hertz
  • Regulatory Approvals : EN/UL/IEC 61010-1; CSA-C22.2 No. 61010-1-12; EN 50270; RED, FCC, BT SIG; UL2075 (CO and CH4); AS 1668.2
  • For Use With : BMS; fire alarm panels; PLCs; HVAC
  • Minimum Operating Pressure : 90kilopascal
  • Indicator LED : Integral alarm status LEDs
  • Maximum Operating Pressure : 110kilopascal
  • Includes : Main detector unit; Flow cap and elbows
  • Enclosure Rating : IP65; Type 4 (NEMA 250)
  • Operating Frequency Range : 50; 60hertz
  • Overall Height : 113 millimetre
  • Overall Weight : 500 gram
  • Minimum Operating Ambient Temperature : −20 degree Celsius
  • Maximum Operating Ambient Temperature : 50 degree Celsius
  • Overall Width : 113 millimetre
  • Maximum Operating Humidity : 99 Percentage
  • Overall Depth : 59 millimetre
  • Minimum Operating Humidity : 0 Percentage
Data Sheet
Name
Description
File Size
Date
Size
VESDA Sensepoint XCL Large Bore Gas Sensors Datasheet
application/pdf 172.91 KB
8/16/2022
172.91 KB
Name
Description
File Size
Date
Size
VESDA Sensepoint XCL Large Bore Gas Sensors Datasheet
172.91 KB
8/16/2022
172.91 KB
Name
Description
File Size
Date
Size
VESDA Sensepoint XCL Large Bore Gas Sensors Datasheet
172.91 KB
8/16/2022