    Emergency Voice / Alarm Communications System

    First Command Emergency Communication System

    Notifier’s First Command NFC-50/100 and NFC-50/100E are multipurpose emergency voice evacuation panels for fire applications, mass notification applications, or both.

    Overview

    Notifier’s First Command NFC-50/100 and NFC-50/100E are multipurpose emergency voice evacuation panels for fire applications, mass notification applications, or both. The First Command delivers 50 or 100 watts of audio power for distribution to up to eight speaker circuits (i.e. zones). The NFC-50/100(E) comes standard with a single speaker circuit and a built-in 50 watt, 25V amplifier. A secondary 50 watt amplifier (NFC-BDA-25/70V) can be added for single speaker circuit backup or to increase system capacity to two speaker circuits and an additional 50 watts of audio power. An optional NFC-CE6 module added to the NFC-50/100(E) will upgrade the system to a maximum of eight speaker circuit outputs. All speaker output circuits can be wired in either Style Y (Class B) or Style Z (Class A) configuration. The NFC-50/100(E) has fourteen field programmable messages (up to 60 seconds each), built-in field configurable pre- and post-announce tone generators and a fully supervised Notification Appliance Circuit (NAC) with 2.0 amps of synchronized NAC power.

    The NFC-50/100(E) includes three builtin Form-C relay contacts, (AC power, trouble and MNS active) a NAC follower and 500mA special application power. A built-in power supply delivers operational power and an onboard battery charger supports charging up to 26AH batteries (NFC cabinet holds up to 18AH batteries).

    For fire protection applications, the NFC-50/100(E) is an adjunct (slave) to any UL listed FACP, providing reverse polarity or contact closure; can be used as a stand-alone unit for non-fire applications. For seamless integration between fire and mass notification, the NFC-50/100(E) can be directly activated via serial communication between the NFW-100X, NFW2-100, NFS-320, or NFS2-640. Activation of the NFC-50/100(E) via other FACPs uses the eight on board Command Input Circuits (CMDs). Two of the eight CMD circuits (CMD 1 & CMD 2) can be individually field programmed for activation by an FACP Notification Appliance Circuit reverse polarity and all eight can be activated by a contact closure. In addition, the NFC-50/100(E) can be activated from a building's Private Branch Exchange (PBX) with the integral night ring feature.

    All NFC-50/100(E) programming is done by using a simple, built-in programming utility accessed from any laptop. For added flexibility, the NFC-50/100(E) supports both 25V and 70V speaker output operation. By adding a 70V transformer conversion module (NFCXRM-70V) or an additional 70 volt secondary amplifier (NFC-BDA25/70V) the system supports 70 volt speaker devices.

    The NFC-50/100(E) can expand in order to accommodate larger or more complex installations. To add more control and increase system capacity, any combination of up to eight external remote consoles (including the NFC-LOC, NFC-RPU, and NFC-RM) and up to eight distributed audio amplifiers (including the NFC-50DA(E), NFC100DA(E) and NFC-125-DA(E) can be connected on the external data bus and audio riser data bus to create a fully integrated command center. A fully loaded system supports up to 1100 watts of total audio power and up to 24 speaker circuit outputs.

    Features & Benefits:
    • Modular design for system flexibility and easy expansion
    • Removable terminal blocks
    • 2 amp Notification Appliance Circuit (NAC) output, sync generator, or follower for System Sensor, Wheelock or Gentex protocols
    • Optional 70Vtransformer available for the primary amplifier. (Note that speaker wiring continues to be supervised in standby, alarm and when background music is playing with this optional transformer installed)
    • Eight Command Input Circuits to activate messages 1 to 8
    Certifications:
    • The listings and approvals below apply to the basic NFC-50/100(E) control panel. In some cases, certain modules may not be listed by certain approval agencies or listing may be in process. Consult factory for latest listing status
    • UL/ULC Listed: S635
    • CSFM: 6911-0028:0265
    • NYC Fire Dept. Certificate of Approval: #6163
    Others
    Name
    Description
    File Size
    Date
    Size
    SEISKIT-COMMENC PID
    application/pdf 460.03 KB
    5/8/2023
    460.03 KB
    NOTIFIER Cybersecurity Manual
    application/pdf 213.73 KB
    10/28/2022
    213.73 KB
    NFC-50-100 First Command Voice Evacuation Panel Engineering Specification
    application/msword 84.5 KB
    5/14/2023
    84.5 KB
    Sales Sheet
    Name
    Description
    File Size
    Date
    Size
    NOTIFIER FirstCommand Sell Sheet
    application/pdf 261.12 KB
    6/15/2022
    261.12 KB
    Data Sheet
    Name
    Description
    File Size
    Date
    Size
    NFC-50DA(E), NFC-125DA(E), NFC-50/100DA Data Sheet
    application/pdf 115.23 KB
    5/14/2023
    115.23 KB
    NFC-LOC Data Sheet
    application/pdf 256.93 KB
    5/14/2023
    256.93 KB
    NFC-RTZM Data Sheet
    application/pdf 121.77 KB
    5/14/2023
    121.77 KB
    NFC-RM Data Sheet
    application/pdf 167.04 KB
    5/14/2023
    167.04 KB
    NFC-50-100C Data Sheet
    application/pdf 516.79 KB
    5/14/2023
    516.79 KB
    NFC-50-100(E) Data Sheet
    application/pdf 531.48 KB
    5/14/2023
    531.48 KB
    NFC-RPU Data Sheet
    application/pdf 185.48 KB
    5/14/2023
    185.48 KB
    Name
    Description
    File Size
    Date
    Size
    NFC-50DA(E), NFC-125DA(E), NFC-50/100DA Data Sheet
    application/pdf 115.23 KB
    5/14/2023
    115.23 KB
    SEISKIT-COMMENC PID
    application/pdf 460.03 KB
    5/8/2023
    460.03 KB
    NOTIFIER Cybersecurity Manual
    application/pdf 213.73 KB
    10/28/2022
    213.73 KB
    NFC-LOC Data Sheet
    application/pdf 256.93 KB
    5/14/2023
    256.93 KB
    NFC-RTZM Data Sheet
    application/pdf 121.77 KB
    5/14/2023
    121.77 KB
    NFC-50-100 First Command Voice Evacuation Panel Engineering Specification
    application/msword 84.5 KB
    5/14/2023
    84.5 KB
    NOTIFIER FirstCommand Sell Sheet
    application/pdf 261.12 KB
    6/15/2022
    261.12 KB
    NFC-RM Data Sheet
    application/pdf 167.04 KB
    5/14/2023
    167.04 KB
    NFC-50-100C Data Sheet
    application/pdf 516.79 KB
    5/14/2023
    516.79 KB
    NFC-50-100(E) Data Sheet
    application/pdf 531.48 KB
    5/14/2023
    531.48 KB
    NFC-RPU Data Sheet
    application/pdf 185.48 KB
    5/14/2023
    185.48 KB
    Name
    Description
    File Size
    Date
    Size
    SEISKIT-COMMENC PID
    460.03 KB
    5/8/2023
    NOTIFIER Cybersecurity Manual
    213.73 KB
    10/28/2022
    NFC-50-100 First Command Voice Evacuation Panel Engineering Specification
    84.5 KB
    5/14/2023
    NOTIFIER FirstCommand Sell Sheet
    261.12 KB
    6/15/2022
    NFC-50DA(E), NFC-125DA(E), NFC-50/100DA Data Sheet
    115.23 KB
    5/14/2023
    NFC-LOC Data Sheet
    256.93 KB
    5/14/2023
    NFC-RTZM Data Sheet
    121.77 KB
    5/14/2023
    NFC-RM Data Sheet
    167.04 KB
    5/14/2023
    NFC-50-100C Data Sheet
    516.79 KB
    5/14/2023
    NFC-50-100(E) Data Sheet
    531.48 KB
    5/14/2023
    NFC-RPU Data Sheet
    185.48 KB
    5/14/2023