    The Gamewell-FCI Velocity® Addressable Monitor Module provides an address for any device or group of devices connected to this circuit on the signaling line circuit (SLC) of the Gamewell-FCI addressable series fire alarm control panel.

    Overview

    The Gamewell-FCI Velocity® Series, addressable monitor module is a single Style B, Class B initiating device circuit (IDC) with a 47KW end-of-line resistor. The addressable monitor module provides a single Style B, Class B initiating device circuit (IDC) with a 47kΩ end-of-line resistor. The addressable monitor module is compatible with the E3 Series, S3 Series, and 7100 Series Fire Alarm Control Panels. This module provides an address for any device or group of devices connected to this circuit on the signaling line circuit (SLC) of the Gamewell-FCI addressable series fire alarm control panel. Any initiating device with normally open (N.O.) dry contacts may be made addressable when connected to the addressable monitor module . The Velocity® Seriems use a communication protocol that substantially increases the speed of communication between the sensors and certain Gamewell-FCI analog addressable fire alarm controls. These devices operate in a grouped fashion. If one of the devices in the group has a status change, the panel’s microprocessor stops the group poll and concentrates on the single device. The net effect is response speed up to five times greater than earlier designs.

    The addressable monitor module can be programmed to provide a wide variety of input functions to the Gamewell-FCI addressable series fire alarm control panels. It can be identified as a manual station, heat detector, plenum detector, water flow switch, tamper switch, N.O. contact, smoke detector, projected beam smoke detector, sub loop, remote zone, etc. It can also serve as a remote system silence, system reset, system acknowledge or drill switch. It is even possible to customize its device type to meet specific job requirements. The initiating device circuit of the AMM-2F can support a maximum line resistance of up to 40 ohms allowing the use of linear heat detection devices. The compact size facilitates the installation of the module inside manual stations, or mounting boxes of various types of alarm initiating devices.

    Specifications

    Others

    • Product Type
      • Module

    Others

    • Product Type
      • Module
    • Product Type : Module
    Others
    Name
    Description
    File Size
    Date
    Size
    AMM-2F Monitor Module Manual
    application/pdf 184.97 KB
    10/3/2024
    184.97 KB
    Supplement to Compatibility Addendum-Installation Manual
    application/pdf 90.98 KB
    10/3/2024
    90.98 KB
    E3 Series A and E Specification - Stand Alone (PDF)
    application/pdf 360.04 KB
    10/3/2024
    360.04 KB
    E3 Series A and E Specification - Network (PDF)
    application/pdf 363.39 KB
    10/3/2024
    363.39 KB
    E3 Series A and E Specification - Voice (PDF)
    application/pdf 427.82 KB
    10/3/2024
    427.82 KB
    E3 Series A and E Specification - Voice (DOCX)
    application/vnd.openxmlformats-officedocument.wordprocessingml.document 78.49 KB
    6/16/2023
    78.49 KB
    E3 Series A and E Specification - Network (DOCX)
    application/vnd.openxmlformats-officedocument.wordprocessingml.document 84.55 KB
    10/3/2024
    84.55 KB
    E3 Series A and E Specification - Stand Alone (DOCX)
    application/vnd.openxmlformats-officedocument.wordprocessingml.document 86.29 KB
    10/3/2024
    86.29 KB
    Brochure
    Name
    Description
    File Size
    Date
    Size
    Isolator Load Rating Table Brochure
    application/pdf 55.33 KB
    1/1/2016
    55.33 KB
    Data Sheet
    Name
    Description
    File Size
    Date
    Size
    AMM-2F Addressable Monitor Module Data Sheet
    application/pdf 136.65 KB
    11/17/2017
    136.65 KB
    AMM-2 Monitor Module Data Sheet
    application/pdf 40.62 KB
    9/10/2024
    40.62 KB
    Catalog
    Name
    Description
    File Size
    Date
    Size
    Engineering and Applications Catalog
    application/pdf 131.74 KB
    5/10/2023
    131.74 KB
    Name
    Description
    File Size
    Date
    Size
    Isolator Load Rating Table Brochure
    application/pdf 55.33 KB
    1/1/2016
    55.33 KB
    AMM-2F Monitor Module Manual
    application/pdf 184.97 KB
    10/3/2024
    184.97 KB
    Supplement to Compatibility Addendum-Installation Manual
    application/pdf 90.98 KB
    10/3/2024
    90.98 KB
    Engineering and Applications Catalog
    application/pdf 131.74 KB
    5/10/2023
    131.74 KB
    AMM-2F Addressable Monitor Module Data Sheet
    application/pdf 136.65 KB
    11/17/2017
    136.65 KB
    AMM-2 Monitor Module Data Sheet
    application/pdf 40.62 KB
    9/10/2024
    40.62 KB
    E3 Series A and E Specification - Stand Alone (PDF)
    application/pdf 360.04 KB
    10/3/2024
    360.04 KB
    E3 Series A and E Specification - Network (PDF)
    application/pdf 363.39 KB
    10/3/2024
    363.39 KB
    E3 Series A and E Specification - Voice (PDF)
    application/pdf 427.82 KB
    10/3/2024
    427.82 KB
    E3 Series A and E Specification - Voice (DOCX)
    application/vnd.openxmlformats-officedocument.wordprocessingml.document 78.49 KB
    6/16/2023
    78.49 KB
    E3 Series A and E Specification - Network (DOCX)
    application/vnd.openxmlformats-officedocument.wordprocessingml.document 84.55 KB
    10/3/2024
    84.55 KB
    E3 Series A and E Specification - Stand Alone (DOCX)
    application/vnd.openxmlformats-officedocument.wordprocessingml.document 86.29 KB
    10/3/2024
    86.29 KB
    Name
    Description
    File Size
    Date
    Size
    AMM-2F Monitor Module Manual
    184.97 KB
    10/3/2024
    Supplement to Compatibility Addendum-Installation Manual
    90.98 KB
    10/3/2024
    E3 Series A and E Specification - Stand Alone (PDF)
    360.04 KB
    10/3/2024
    E3 Series A and E Specification - Network (PDF)
    363.39 KB
    10/3/2024
    E3 Series A and E Specification - Voice (PDF)
    427.82 KB
    10/3/2024
    E3 Series A and E Specification - Voice (DOCX)
    78.49 KB
    6/16/2023
    E3 Series A and E Specification - Network (DOCX)
    84.55 KB
    10/3/2024
    E3 Series A and E Specification - Stand Alone (DOCX)
    86.29 KB
    10/3/2024
    Isolator Load Rating Table Brochure
    55.33 KB
    1/1/2016
    AMM-2F Addressable Monitor Module Data Sheet
    136.65 KB
    11/17/2017
    AMM-2 Monitor Module Data Sheet
    40.62 KB
    9/10/2024
    Engineering and Applications Catalog
    131.74 KB
    5/10/2023
    Part Number
    Description
    Leaf Category
    Thumbnail
    Add to list