Signal control element devices are the interface between the 600 Series and ILI95-E3 Series® fire alarm control panel's (FACPs) analog circuits and building functions.

Signal control element devices are the interface between the 600 Series and ILI95-E3 Series® fire alarm control panel's (FACPs) analog circuits and building functions. Signal control element devices connect to the panel via the SLC circuit. Signal control element devices provide a means to remotely locate a fully supervised circuit for the operation of signaling appliances such as horns and strobes. For annunciation and feedback at the panel, Gamewell-FCI® offers a signal control display (SCD). The SCD is only available with the IdentiFlex™ 632 and IF650 FACPs.

Signal control element devices are capable of switching 24V DC. When used as a remote signaling circuit, signal control element devices provide all the necessary supervision of the circuit and trouble reporting via the analog circuit. They can be surface- or flush-mounted and have an integral LED, which annunciates upon device activation.

Signal control element devices connect to the SLC of the FACP via two wires. In their standby mode, signal control element devices monitor their internal circuitry for status of the devices themselves and supervise the external control circuit for faults. In the event that a fault is detected, they will report a trouble to the FACP. When an event is reported to the FACP that requires the activation of the signal control element device, the control panel communicates via the analog circuit to the device and the signaling circuit is actuated. The integral LED is also lit for annunciation at the device.

Features & Benefits:
  • Supervises and operates the notification appliance circuit
  • Supervises DC power
  • Field programmable
  • Style 4, 6, or 7 wiring
  • Includes screw terminals for field-wiring connections
  • Supports 24V, 2A output
Certifications:
  • UL Listed: S521
  • FM Approved
  • FDNY: Approved
  • CSFM: 7300-1703:0135
  • ISO 9001 Certification

Others

  • End of Line Resistance
    • 3.9 kO
  • Maximum Operating Humidity
    • 85 Percentage
  • Maximum Operating Voltage
    • 21Vdc from Analog Addressable Module
  • Alarm Current
    • 1.7 milliampere
  • Brand
    • Gamewell-FCI

Others

  • End of Line Resistance
    • 3.9 kO
  • Maximum Operating Humidity
    • 85 Percentage
  • Maximum Operating Voltage
    • 21Vdc from Analog Addressable Module
  • Alarm Current
    • 1.7 milliampere
  • Brand
    • Gamewell-FCI
  • Brand : Gamewell-FCI
  • End of Line Resistance : 3.9 kO
  • Maximum Operating Humidity : 85 Percentage
  • Maximum Operating Voltage : 21Vdc from Analog Addressable Module
  • Alarm Current : 1.7 milliampere
Engineering Specifications
Name
Description
File Size
Date
Size
E3 Series A and E Specification - Voice (DOCX)
application/vnd.openxmlformats-officedocument.wordprocessingml.document 78.49 KB
5/18/2022
78.49 KB
E3 Series A and E Specification - Network (DOCX)
application/vnd.openxmlformats-officedocument.wordprocessingml.document 84.55 KB
5/18/2022
84.55 KB
E3 Series A and E Specification - Stand Alone (DOCX)
application/vnd.openxmlformats-officedocument.wordprocessingml.document 86.29 KB
5/18/2022
86.29 KB
E3 Series A and E Specification - Network (PDF)
application/pdf 356.91 KB
5/18/2022
356.91 KB
E3 Series A and E Specification - Stand Alone (PDF)
application/pdf 353.47 KB
5/18/2022
353.47 KB
IdentiFlex 602 SmartScan AandE Specification
application/msword 129.5 KB
5/18/2022
129.5 KB
632 Network Specification
application/msword 147.5 KB
5/18/2022
147.5 KB
650 Network Specification
application/msword 147 KB
5/18/2022
147 KB
610 Stand Alone Specification
application/msword 243.5 KB
5/18/2022
243.5 KB
610 Network Specification
application/msword 147.5 KB
5/18/2022
147.5 KB
602 Network Specification
application/msword 144 KB
5/18/2022
144 KB
Data Sheet
Name
Description
File Size
Date
Size
INS 2 Control Element Data Sheet
application/pdf 451.18 KB
5/18/2022
451.18 KB
XP Mod SCE-95 Signal Control Element Data Sheet
application/pdf 68.17 KB
5/18/2022
68.17 KB
IdentiFlex 600 Series Control Element Devices Data Sheet
application/pdf 350.24 KB
5/18/2022
350.24 KB
Catalog
Name
Description
File Size
Date
Size
Engineering and Applications Catalog
application/pdf 131.74 KB
5/18/2022
131.74 KB
Others
Name
Description
File Size
Date
Size
E3 Series A and E Specification - Voice (PDF)
application/pdf 421.32 KB
5/18/2022
421.32 KB
Name
Description
File Size
Date
Size
E3 Series A and E Specification - Voice (DOCX)
78.49 KB
5/18/2022
78.49 KB
E3 Series A and E Specification - Network (DOCX)
84.55 KB
5/18/2022
84.55 KB
E3 Series A and E Specification - Stand Alone (DOCX)
86.29 KB
5/18/2022
86.29 KB
E3 Series A and E Specification - Voice (PDF)
421.32 KB
5/18/2022
421.32 KB
E3 Series A and E Specification - Network (PDF)
356.91 KB
5/18/2022
356.91 KB
E3 Series A and E Specification - Stand Alone (PDF)
353.47 KB
5/18/2022
353.47 KB
INS 2 Control Element Data Sheet
451.18 KB
5/18/2022
451.18 KB
XP Mod SCE-95 Signal Control Element Data Sheet
68.17 KB
5/18/2022
68.17 KB
IdentiFlex 600 Series Control Element Devices Data Sheet
350.24 KB
5/18/2022
350.24 KB
Engineering and Applications Catalog
131.74 KB
5/18/2022
131.74 KB
IdentiFlex 602 SmartScan AandE Specification
129.5 KB
5/18/2022
129.5 KB
632 Network Specification
147.5 KB
5/18/2022
147.5 KB
650 Network Specification
147 KB
5/18/2022
147 KB
610 Stand Alone Specification
243.5 KB
5/18/2022
243.5 KB
610 Network Specification
147.5 KB
5/18/2022
147.5 KB
602 Network Specification
144 KB
5/18/2022
144 KB