Manual Call Points/Pull Stations

Outdoor Manual Call Point

Outdoor Manual Call Points are sealed manual call point product. They are supplied with both an LED, resistor and normally open, clean contact electrical options.

Outdoor Manual Call Points are sealed manual call point product. They are supplied with both an LED, resistor and normally open, clean contact electrical options. Installation time and ultimately cost, are of paramount importance to any fire or security installer. The WCP range directly reflects this need by providing a unique ‘plug and play’ concept designed specifically to reduce installation time. All new WCP products utilise a special terminal block, where all initial installation cabling is terminated. This terminal block is then simply connected to the back of the WCP. Simple, but effective with no re-termination required and no time wasted. In addition, all WCP products are supplied with three standard 20mm threaded cable entries, accommodating all types of surface wiring installations.

Features & Benefits:
  • Unique ‘Plug & Play’ installation concept
  • Total ‘Flex-Ability’ in the choice of operating element
  • Anti-Tamper facility
  • Enhanced aesthetics and compact design
  • Fully approved to the latest standards
  • CPD Approval
Certifications:
  • IP 67
  • LPCB
  • EN54-11

Others

  • Contact Ratings
    • 2 A @ 30 Switching voltage direct current
  • Minimum Operating Ambient Temperature
    • -25 degree Celsius
  • Material
    • Polycarbonate/ABS
  • Maximum Operating Humidity
    • 93Percentage
  • Brand
    • KAC
    • System Sensor

Others

  • Contact Ratings
    • 2 A @ 30 Switching voltage direct current
  • Minimum Operating Ambient Temperature
    • -25 degree Celsius
  • Material
    • Polycarbonate/ABS
  • Maximum Operating Humidity
    • 93Percentage
  • Brand
    • KAC
    • System Sensor
  • Material : Polycarbonate/ABS
  • Maximum Operating Humidity : 93Percentage
  • Brand : KAC|System Sensor
  • Contact Ratings : 2 A @ 30 Switching voltage direct current
  • Minimum Operating Ambient Temperature : -25 degree Celsius
Image
SKU
Description
alt
W2A-R039SG-T200-06
514.001.112-BC002R-GL1140-F 22
alt
W2A-R470SG-T200-03
514.001.110.Y-WCP2A-BC002R-GL1140-F222
alt
W2A-R470SF-A071-02
Outdoor Manual Call Point: 30V DC: 2A: 470 Ω/1W: -25 to 70C: Red: Type A: Apollo
alt
W2A-R220SG-T200-83
514.001.109-WCP2A
alt
W2A-R470SF-P032-01
WCP2A FE681-F 222
alt
W2A-Y470SG-K013-11
WCP2A-470-GL1140-PLAIN
alt
W2A-R470SG-K013-81
WCP2A-470-GL1140-F 222
alt
W2A-R470SF-K013-01
Outdoor Manual Call Point: 30V DC: 2A: 470 Ω/1W: -25 to 70C: Red: Type A: WCP: KAC
alt
W2A-R820SF-A207-41
WCP2A/CG1/C-120-820
alt
W2A-R470SG-T200-02
514.001.110.T-WCP2A-BC004R-GL1140-F222