Fire Alarm Control Panels

Flex 506 Fire Alarm Control Panel

The Flex GF506D is a six-zone fire alarm control panel FACP that is used for single and dual hazard deluge and pre-action applications.

The Flex GF506D is a six-zone fire alarm control panel FACP that is used for single and dual hazard deluge and pre-action applications. The Flex GF506D provides reliable fire detection. It also offers signalling and protection for commercial, industrial, and institutional buildings that require water-based releasing. The Flex GF506D is compatible with System Sensor’s® i3 detectors.

The i3 detectors are conventional smoke detectors that transmit a maintenance trouble signal to the FACP that indicates the need for cleaning. It also transmits a supervisory ‘freeze’ signal when the ambient temperature falls below the detector rating of approximately 45F (7.22C). The Product supervises all wiring, AC voltage, battery charger, and battery level. The activation of a compatible smoke detector or any normally open fire alarm

Features & Benefits:
  • Designed for sprinkler standards NFPA 13, 15 and 16
  • Dual hazard operation
  • Adjustable waterflow discharge timer and two soak timers
  • Cross-zone (doubleinterlock) capability
  • Six programmable Style B (Class B) IDCs (Initiating Device Circuit) with optional Class A wiring
Certifications:
  • UL: S624
  • FM Approved
  • CSFM: 7165-1703: 0171
  • ISO 9001 Certification

Others

  • Standby Current
    • 4 milliampere
  • Operating Voltage
    • 20 voltage direct current
  • Maximum Battery Capacity
    • 26
  • Output Current
    • 15 milliampere
  • Conventional / Addressable
    • Conventional
  • Display Size
    • 8
  • For Use With
    • Backbox
    • System Sensor i3 Detectors
  • Loop Capacity
    • 6
  • Main Frequency
    • 50/60hertz

Others

  • Standby Current
    • 4 milliampere
  • Operating Voltage
    • 20 voltage direct current
  • Maximum Battery Capacity
    • 26
  • Output Current
    • 15 milliampere
  • Conventional / Addressable
    • Conventional
  • Display Size
    • 8
  • For Use With
    • Backbox
    • System Sensor i3 Detectors
  • Loop Capacity
    • 6
  • Main Frequency
    • 50/60hertz
  • Conventional / Addressable : Conventional
  • Display Size : 8
  • For Use With : Backbox|System Sensor i3 Detectors
  • Loop Capacity : 6
  • Main Frequency : 50/60hertz
  • Standby Current : 4 milliampere
  • Operating Voltage : 20 voltage direct current
  • Maximum Battery Capacity : 26
  • Output Current : 15 milliampere
Sort
Others
Document Title
File Size
Date Added
Asset Language
Content Type
Engineering Specifications
Document Title
File Size
Date Added
Asset Language
Content Type
Manuals and Guides
Document Title
File Size
Date Added
Asset Language
Content Type
Data Sheet
Document Title
File Size
Date Added
Asset Language
Content Type
Catalog
Document Title
File Size
Date Added
Asset Language
Content Type
Image
SKU
Description
alt
GF506D
Conventional Control Panel, 120V AC, 50/60Hz, 2.3A, Single and Dual Hazard Deluge and Pre-action
alt
GF506R
Conventional Control Panel: 120V AC: 50/60Hz: 2.3A: Single and Dual Hazard Agent Releasing