IDP Intelligent Addressable Monitor Module

IDP intelligent addressable monitor modules are intended for use in an intelligent alarm system. Each monitor module is intended to interface between a control panel and normally open contact devices, such as pull stations.

IDP intelligent addressable monitor modules are intended for use in an intelligent alarm system. Each monitor module is intended to interface between a control panel and normally open contact devices, such as pull stations. A common signaling line circuit (SLC) input is used for all modules and the initiating device loops share a common supervisory supply and ground. Otherwise, each monitor operates independently from the others. Each module has its own unique address. A pair of rotary code switches is used to set the address of the first module from 01 to 90. The remaining modules are automatically assigned to the next nine higher addresses. Provisions are included for disabling a maximum of two unused modules to release the addresses to be used elsewhere. Each module also has panel controlled green LED indicators. The panel can cause the LEDs to blink, latch on, or latch off.

Features & Benefits:
  • 10 contact monitor
  • Support for Class A and Class B wiring
  • Fully supervised
  • LED indicator for each input
  • Disable unused addresses
  • Mount up to two modules in one accessory cabinet (PN IDPACB)
  • Rotary address switches for fast installation
  • Removable 12 to 18 AWG plug-in terminal blocks for easy wiring and troubleshooting
  • Mounting hardware included
Certifications:
  • UL
  • CSFM
  • MEA

Others

  • Maximum Operating Humidity
    • 0.93
  • Alarm Current
    • 750 µA
  • End of Line Resistance
    • 47 kO
  • For Use With
    • Fire Alarm
  • Brand
    • Farenhyt
  • Approved Location
    • MEA 457-99-E Vol.V
    • UL Listed

Others

  • Maximum Operating Humidity
    • 0.93
  • Alarm Current
    • 750 µA
  • End of Line Resistance
    • 47 kO
  • For Use With
    • Fire Alarm
  • Brand
    • Farenhyt
  • Approved Location
    • MEA 457-99-E Vol.V
    • UL Listed
  • For Use With : Fire Alarm
  • Brand : Farenhyt
  • Approved Location : MEA 457-99-E Vol.V|UL Listed
  • Maximum Operating Humidity : 0.93
  • Alarm Current : 750 µA
  • End of Line Resistance : 47 kO
Others
Name
Description
File Size
Date
Size
Dispositivos direccionales con Protocolo de dispositivo inteligente Data Sheet
application/pdf 319.51 KB
5/9/2022
319.51 KB
Addressable Device Guide
application/pdf 634.41 KB
5/9/2022
634.41 KB
IFP-1000 Sales Guide
application/pdf 654.91 KB
5/9/2022
654.91 KB
Farenhyt Accessories Guide Brochure
application/pdf 634.41 KB
5/9/2022
634.41 KB
IDP-Zone Addressable Zone Interface Module Fire Listing
application/pdf 166.94 KB
5/9/2022
166.94 KB
Analog-Addressable Devices with Intelligent Device Protocol Data Sheet
application/pdf 273.93 KB
5/7/2022
273.93 KB
IDP-MONITOR-10 Addressable Monitor Multi-Module Data Sheet
application/pdf 821.46 KB
5/7/2022
821.46 KB
350296 G IDP-Monitor-10 Datasheet
0 Bytes
5/5/2022
0 Bytes
Isolator Load Rating Table Brochure
application/pdf 38.09 KB
3/9/2022
38.09 KB
Name
Description
File Size
Date
Size
Dispositivos direccionales con Protocolo de dispositivo inteligente Data Sheet
319.51 KB
5/9/2022
319.51 KB
Addressable Device Guide
634.41 KB
5/9/2022
634.41 KB
IFP-1000 Sales Guide
654.91 KB
5/9/2022
654.91 KB
Farenhyt Accessories Guide Brochure
634.41 KB
5/9/2022
634.41 KB
IDP-Zone Addressable Zone Interface Module Fire Listing
166.94 KB
5/9/2022
166.94 KB
Analog-Addressable Devices with Intelligent Device Protocol Data Sheet
273.93 KB
5/7/2022
273.93 KB
IDP-MONITOR-10 Addressable Monitor Multi-Module Data Sheet
821.46 KB
5/7/2022
821.46 KB
350296 G IDP-Monitor-10 Datasheet
0 Bytes
5/5/2022
0 Bytes
Isolator Load Rating Table Brochure
38.09 KB
3/9/2022
38.09 KB
Image
SKU
Description
alt
IDP-MONITOR-10
Intelligent Addressable Monitor Module: Supervised: 10 Points