https://buildings.honeywell.com/us/en/search-results.html

Monitors

Monitor Module

NDM -100 Notifier Dual Monitor Module is intended for use in intelligent, two-wire systems. It provides two independent two-wire initiating device circuits (IDCs) at two separate, consecutive addresses.

NDM-100(A) is a standard-sized dual monitor module that monitors and supervises two independent two-wire Style B (Class B) dry-contact initiating device circuits (IDCs) at two separate, consecutive addresses in intelligent, two-wire systems. General Four different monitor modules are available for Notifier’s FireWarden Series intelligent control panels for a variety of applications. Monitor modules supervise a circuit of dry-contact input devices, such as conventional heat detectors and pull stations, or monitor and power a circuit of two-wire smoke detectors (NZM-100(A)). NDM-100(A) is a standard-sized dual monitor module that monitors and supervises two independent two-wire Style B (Class B) dry-contact initiating device circuits (IDCs) at two separate, consecutive addresses in intelligent, two-wire systems.

Features & Benefits:
  • Built-in type identification automatically identifies this device as a monitor module to the control panel
  • Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity
  • SEMS screws with clamping plates for ease of wiring
  • Direct-dial entry of address: 01 – 99 on FireWarden-100- 2, 01 – 50 on FireWarden-50
  • LED flashes during normal operation and latches on steady to indicate alarm.
Certifications:
  • UL: S635
  • ULC: S635
  • FM Approved

Others

  • Cabinet Width
    • 4 inch
    • 10.16 centimetre
  • Maximum Operating Humidity
    • 93 Percentage
  • Cabinet Depth
    • 2.125 inch
    • 5.398 centimetre
  • Cabinet Height
    • 4 inch
    • 10.16 centimetre
  • Maximum IDC Wiring Resistance
    • 1500ohm
  • Brand
    • System Sensor
    • NOTIFIER

Others

  • Cabinet Width
    • 4 inch
    • 10.16 centimetre
  • Maximum Operating Humidity
    • 93 Percentage
  • Cabinet Depth
    • 2.125 inch
    • 5.398 centimetre
  • Cabinet Height
    • 4 inch
    • 10.16 centimetre
  • Maximum IDC Wiring Resistance
    • 1500ohm
  • Brand
    • System Sensor
    • NOTIFIER
  • Maximum IDC Wiring Resistance : 1500ohm
  • Brand : System Sensor|NOTIFIER
  • Cabinet Height : 4 inch|10.16 centimetre
  • Cabinet Width : 4 inch|10.16 centimetre
  • Maximum Operating Humidity : 93 Percentage
  • Cabinet Depth : 2.125 inch|5.398 centimetre
Others
Name
Description
File Size
Date
Size
Isolator Load Rating Table Brochure
application/pdf 38.09 KB
3/9/2022
38.09 KB
Name
Description
File Size
Date
Size
Isolator Load Rating Table Brochure
38.09 KB
3/9/2022