/content/hbtbt/us/en/search-results.html

Aspirating Smoke Detector

Fire Alarm Aspiration Sensing Technology (FAAST) Aspirating Smoke Detector

(FAAST)Fire Alarm Aspiration Sensing Technology by System Sensor is an advanced fire detection system for use where early warning and very early warning are a requirement.

Overview

The NP-200 Series intelligent plug-in smoke detectors are designed for both performance and aesthetics, and are direct replacements for the NP-100 Series. A new modern, sleek, contemporary design and enhanced optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources in accordance with more stringent code standards. Exclusively for use with NOTIFIER’s Fire Warden Series addressable fire alarm control panels, the NP-200 Series point ID capability allows each detector’s address to be set with rotary, decimal address switches, providing exact detector location for emergency personnel to quickly locate a fire during its early stages, potentially saving precious rescue time while also reducing property damage. Two LEDs on each sensor light to provide a local, visible sensor indication.

Features & Benefits:
  • SLC Loop:
  • Two-wire SLC loop connection
  • Unit uses base for wiring
  • Compatible with Flash Scan® and CLIP protocol systems
  • Stable communication technique with noise immunity
  • Addressing:
  • Addressable by device
Certifications:
  • UL/ULC Listing: S1115
  • FM Approved
  • CSFM: 7272-0028:0503
Specifications

Others

  • Minimum Operating Humidity
    • 10 Percentage
  • Maximum Operating Humidity
    • 93 Percentage
  • Maximum Operating Voltage
    • 15 - 32 (Peak) voltage direct current
  • Maximum Standby Current
    • 200 µA @ 24 voltage direct current
  • Brand
    • Notifier
    • System Sensor
  • Conventional or Addressable
    • Addressable
  • Detection Sensor Type
    • Photoelectric inch
  • Wiring Type
    • 2-Wire Square millimeter
  • Sensitivity
    • 0.5 - 3.5 Percentage
    • 0.5 - 4 Percentage
  • Material
    • Plastic

Others

  • Minimum Operating Humidity
    • 10 Percentage
  • Maximum Operating Humidity
    • 93 Percentage
  • Maximum Operating Voltage
    • 15 - 32 (Peak) voltage direct current
  • Maximum Standby Current
    • 200 µA @ 24 voltage direct current
  • Brand
    • Notifier
    • System Sensor
  • Conventional or Addressable
    • Addressable
  • Detection Sensor Type
    • Photoelectric inch
  • Wiring Type
    • 2-Wire Square millimeter
  • Sensitivity
    • 0.5 - 3.5 Percentage
    • 0.5 - 4 Percentage
  • Material
    • Plastic
  • Minimum Operating Humidity : 10 Percentage
  • Maximum Operating Humidity : 93 Percentage
  • Maximum Operating Voltage : 15 - 32 (Peak) voltage direct current
  • Maximum Standby Current : 200 µA @ 24 voltage direct current
  • Brand : Notifier|System Sensor
  • Conventional or Addressable : Addressable
  • Detection Sensor Type : Photoelectric inch
  • Wiring Type : 2-Wire Square millimeter
  • Sensitivity : 0.5 - 3.5 Percentage|0.5 - 4 Percentage
  • Material : Plastic
Sort
Data Sheet
Document Title
Document Type
File Size
Document Title
Document Type
File Size
Product Number
Part Number
Description
Add to list
NP-200T
INTELLIGENT ADDRESSABLE PHOTOTHERMAL DETECTOR; WITH BASE; WHITE
NP-200T-IV
Photoelectric smoke detection with thermal detection: 32F to 100F
Image
SKU
Description
alt
NP-200T
INTELLIGENT ADDRESSABLE PHOTOTHERMAL DETECTOR; WITH BASE; WHITE
alt
NP-200T-IV
Photoelectric smoke detection with thermal detection: 32F to 100F