/content/hbtbt/us/en/search-results.html

Smoke Detectors

Addressable Photoelectric Detector

Addressable Photoelectric Detector by Notifier is use for state-of-the-art photoelectric sensing chamber with communications to provide open area protection.

Overview

The NP-100R addressable, low-profile plug-in photoelectric detectors use a state-of-the-art photoelectric sensing chamber with communications to provide open area protection and are used exclusively with NOTIFIER’s FireWarden Series (FireWarden-100-2 and FireWarden-50) Fire Alarm Control Panels. The NP-100R is a remote test capable detector for use with DNR(A)/DNRW duct smoke detector housings. The NP-100R photoelectric detectors provide a broad range of fire-sensing capability, especially where smoldering fires are anticipated. Ionization detectors are often better than photoelectric detectors at sensing fast, flaming fires.

The addressable photoelectric sensor in the NP-100 series has a unique unipolar chamber that responds quickly and uniformly to a broad range of smoke conditions. It can withstand wind gusts up to 4,000 feet-per-minute (20 m/sec.) without sending an alarm level signal. Because of its unipolar chamber, the NP-100 series is approximately two times more responsive than most photoelectric sensors. This makes it a more stable detector.

Features & Benefits:
  • Low standby current
  • Fully coated circuit boards and superior RF/transient protection
  • Two-wire loop connection
  • Sleek, low-profile design
  • Integral communications and built-in type identification
  • Visible LED “blinks” when the unit is addressed (communicating with the fire panel) and latches on in alarm.
Certifications:
  • UL Listed: S111
  • ULC Listed: S1115
  • CSFM: 7272-0028:0231
  • MEA: 243-02-E Vol. 2
  • Maryland State Fire Marshal: permit 2173
  • FM approved
Specifications

Others

  • Minimum Operating Humidity
    • 10 Percentage
  • Maximum Operating Humidity
    • 93 Percentage
  • Conventional or Addressable
    • Addressable
  • Brand
    • Notifier
    • System Sensor
  • Wiring Type
    • 2-Wire Square millimeter
  • Detection Sensor Type
    • Photoelectric inch

Others

  • Minimum Operating Humidity
    • 10 Percentage
  • Maximum Operating Humidity
    • 93 Percentage
  • Conventional or Addressable
    • Addressable
  • Brand
    • Notifier
    • System Sensor
  • Wiring Type
    • 2-Wire Square millimeter
  • Detection Sensor Type
    • Photoelectric inch
  • Minimum Operating Humidity : 10 Percentage
  • Maximum Operating Humidity : 93 Percentage
  • Conventional or Addressable : Addressable
  • Brand : Notifier|System Sensor
  • Wiring Type : 2-Wire Square millimeter
  • Detection Sensor Type : Photoelectric inch
Sort
Brochure
Document Title
Document Type
File Size
Data Sheet
Document Title
Document Type
File Size
Data Sheet
0.08 MB
Document Title
Document Type
File Size