    Spyder® BACnet® PUB programmable controllers are designed to control HVAC equipment. These controllers provide many options and advanced system features that allow state-of-the-art commercial building control.

    Overview

    \Spyder® BACnet® PUB programmable controllers are designed to control HVAC equipment. These controllers provide many options and advanced system features that allow state-of-the-art commercial building control. Each controller is programmable and configurable through software. These controllers are for use in Variable Air Volume (VAV), Unitary, and advanced HVAC applications. Each controller has flexible, universal inputs for external sensors, digital inputs, and a combination of analog and digital Triac outputs.

    Features & Benefits:
    • Each controller communicates via an EIA-485 BACnet MS/TP network communications network, capable of baud rates between 9.6 and 115.2 kilobits
    • Controllers are field-mountable to either a panel or a DIN rail
    • Rated Voltage: 20–30V AC; 50/60 Hz 
    • LED provides status for normal operation, controller download process, alarms, manual mode, and error conditions
    Certifications:
    • UL/cUL (E87741) listed under UL916 (Standard for Open
    • Energy Management Equipment) with plenum rating.
    • CSA (LR95329-3) listed.
    • Meets FCC Part 15, Subpart B, Class B (radiated
    • emissions) requirements.
    • Meets Canadian standard C108.8 (radiated emissions).
    • EMC Directive: 2014/30/EU:
    • Standards Applied:
    • — IEC 61000-4-8:2009
    • — IEC 61000-4-11:2004
    • — EN 61000-6-1: 2007; EN 61000-6-3:2007/A1:2011;
    • EN 61000-6-3:2007/A1:2011/AC: 2012
    • — EN 60730-2-9: 2010, EN 60730-2-14: 1997 +
    • EN60730-2-14/A1: 2001.
    • — In conjunction with EN 60730-2-9:2010 and in
    • conjunction with EN 60730-2-14:1997 and
    • amendments: EN 60730-1: 2000 + A1: 2004 + A16:
    • 2007 + A2: 2008 -Annex H.26.
    • RoHS Directive: 2011/65/EU
    • Standards Applied:
    • — EN 50581: 2012
    • BTL B-ASC (BACnet Testing Laboratories, BACnet
    • Application Specific Controller)
    Honeywell will provide product support until
    Name
    Date
    Size
    No Resources documents tagged to this product
    An error occurred . Please try after sometime
    Product Number
    Part Number
    Compare
    Description
    Leaf Category
    Thumbnail
    Add to list
    PUB1012S-ILC/U
    Spyder BACnet ILC Programmable Controller, 1 Universal0 Digital Inputs, 1 Analog2 Digital Outputs
    https://honeywell.scene7.com/is/image/Honeywell65/ba-bms-pub1012s-ilc-u
    PUB1012S-ILC/U
    Spyder BACnet ILC Programmable Controller, 1 Universal0 Digital Inputs, 1 Analog2 Digital Outputs
    https://honeywell.scene7.com/is/image/Honeywell65/ba-bms-pub1012s-ilc-u
    PUB1012S/U
    Spyder BACnet Programmable Controller, 1 UI, 1 AO, 2 DO
    https://honeywell.scene7.com/is/image/Honeywell65/hbt-bms-pub1012s-u-spyder-micro-bacnet-primaryimage
    PUB1012S/U
    Spyder BACnet Programmable Controller, 1 UI, 1 AO, 2 DO
    https://honeywell.scene7.com/is/image/Honeywell65/hbt-bms-pub1012s-u-spyder-micro-bacnet-primaryimage
    PUB4024S-ILC/U
    Spyder ILC Programmable Controller, BACnet, 4 UI, 0 DI, 2 AO, 4 DO
    https://honeywell.scene7.com/is/image/Honeywell65/hbt-bms-pub4024s-ilc-u-unitary-controller-bacnet-ilc-4-uis-0-primaryimage
    PUB4024S-ILC/U
    Spyder ILC Programmable Controller, BACnet, 4 UI, 0 DI, 2 AO, 4 DO
    https://honeywell.scene7.com/is/image/Honeywell65/hbt-bms-pub4024s-ilc-u-unitary-controller-bacnet-ilc-4-uis-0-primaryimage
    PUB4024S/U
    Spyder BACnet Programmable Controller, 4 UI, 2 AO, 4 DO
    https://honeywell.scene7.com/is/image/Honeywell65/hbt-bms-pub4024s-u-spyder-micro-bacnet-primaryimage
    PUB4024S/U
    Spyder BACnet Programmable Controller, 4 UI, 2 AO, 4 DO
    https://honeywell.scene7.com/is/image/Honeywell65/hbt-bms-pub4024s-u-spyder-micro-bacnet-primaryimage
    PUB6438S-ILC/U
    Spyder BACnet ILC Programmable Controller, 6 Universal4 Digital Inputs, 3 Analog8 Digital Outputs
    https://honeywell.scene7.com/is/image/Honeywell65/hbt-bms-pub6438s-ilc-u-spyder-bacnet-ilc-primaryimage
    PUB6438S-ILC/U
    Spyder BACnet ILC Programmable Controller, 6 Universal4 Digital Inputs, 3 Analog8 Digital Outputs
    https://honeywell.scene7.com/is/image/Honeywell65/hbt-bms-pub6438s-ilc-u-spyder-bacnet-ilc-primaryimage
    PUB6438S/U
    Spyder BACnet Programmable Controller, 6 UI, 4 DI, 3 AO, 8 DO
    https://honeywell.scene7.com/is/image/Honeywell65/hbt-bms-pub6438s-u-spyder-unitary-bacnet-primaryimage
    PUB6438S/U
    Spyder BACnet Programmable Controller, 6 UI, 4 DI, 3 AO, 8 DO
    https://honeywell.scene7.com/is/image/Honeywell65/hbt-bms-pub6438s-u-spyder-unitary-bacnet-primaryimage
    PUB6438SR-ILC/U
    Spyder ILC Programmable Unitary Controller, BACnet, with Relays
    https://honeywell.scene7.com/is/image/Honeywell65/hbt-bms-pub6438sr-ilc-u-spyder-bacnet-ilc-w-relays-primaryimage
    PUB6438SR-ILC/U
    Spyder ILC Programmable Unitary Controller, BACnet, with Relays
    https://honeywell.scene7.com/is/image/Honeywell65/hbt-bms-pub6438sr-ilc-u-spyder-bacnet-ilc-w-relays-primaryimage
    PUB6438SR/U
    Spyder Programmable Unitary Controller, BACnet, Relays
    https://honeywell.scene7.com/is/image/Honeywell65/hbt-bms-pub6438sr-u-spyder-bacnet-w-relays-primaryimage
    PUB6438SR/U
    Spyder Programmable Unitary Controller, BACnet, Relays
    https://honeywell.scene7.com/is/image/Honeywell65/hbt-bms-pub6438sr-u-spyder-bacnet-w-relays-primaryimage