    Pressure Switches & Sensors

    Setra 264 Series Low DP Transducer

    Low differential pressure transducers of 264 Series uses a dead-ended stainless steel welded capacitive sensing element that requires minimal amplification and delivers excellent accuracy and long term stability in critical installations.

    Overview

    Low differential pressure transducers of 264 Series uses a dead-ended stainless steel welded capacitive sensing element that requires minimal amplification and delivers excellent accuracy and long term stability in critical installations.

    Features & Benefits:
    • Industry standard
    • ±0.25%, ±0.4%, ±1% FS accuracy
    • 3 year unconditional warranty
    • Up to 10 PSI overpressure (range dependent)
    • Installation time minimized with mounting options
    • Reverse wiring protection Internal regulation permits use with unregulated DC power supplies
    Certifications:
    • CE
    • Fire retardant case (UL 94 V-0 approved)
    • RoHS
    Specifications

    Others

    • Connection Size
      • 3/16 inch
    • Output Signal
      • 4 - 20 milliampere
    • Minimum Storage Temperature
      • -54°C
      • -65°F
    • Minimum Operating Ambient Temperature
      • -18 degree Celsius
      • 0 degree Fahrenheit
    • Maximum Storage Temperature
      • 121 degree Celsius
      • 250 degree Fahrenheit
    • Maximum Operating Ambient Temperature
      • 175 degree Fahrenheit
      • 79 degree Celsius
    • Mounting Type
      • 4 Screw Holes inch
    • Brand
      • Alerton
    • Connection Type
      • Barbed
    • Pressure Type
      • Differential

    Others

    • Connection Size
      • 3/16 inch
    • Output Signal
      • 4 - 20 milliampere
    • Minimum Storage Temperature
      • -54°C
      • -65°F
    • Minimum Operating Ambient Temperature
      • -18 degree Celsius
      • 0 degree Fahrenheit
    • Maximum Storage Temperature
      • 121 degree Celsius
      • 250 degree Fahrenheit
    • Maximum Operating Ambient Temperature
      • 175 degree Fahrenheit
      • 79 degree Celsius
    • Mounting Type
      • 4 Screw Holes inch
    • Brand
      • Alerton
    • Connection Type
      • Barbed
    • Pressure Type
      • Differential
    • Connection Size : 3/16 inch
    • Output Signal : 4 - 20 milliampere
    • Minimum Storage Temperature : -54°C|-65°F
    • Minimum Operating Ambient Temperature : -18 degree Celsius|0 degree Fahrenheit
    • Maximum Storage Temperature : 121 degree Celsius|250 degree Fahrenheit
    • Maximum Operating Ambient Temperature : 175 degree Fahrenheit|79 degree Celsius
    • Mounting Type : 4 Screw Holes inch
    • Brand : Alerton
    • Connection Type : Barbed
    • Pressure Type : Differential
    Product Number
    Part Number
    Description
    Leaf Category
    Thumbnail
    Add to list
    2641 001WB 11 T1 C
    Low DP Transducer, Model 264, +-1wc, 4 to 20mA, Terminal Strip, +-1% FS
    2641 001WB 11 T1 C
    Low DP Transducer, Model 264, +-1wc, 4 to 20mA, Terminal Strip, +-1% FS
    2641 001WB 11 T1 F
    Low DP Transducer, Model 264, +-1wc, 4 to 20mA, Terminal Strip, +-0.25% FS
    2641 001WB 11 T1 F
    Low DP Transducer, Model 264, +-1wc, 4 to 20mA, Terminal Strip, +-0.25% FS
    2641 001WD 11 A1 E
    Low DP Transducer, Model 264, 0 to 1wc, 4 to 20mA, Conduit, +-0.4% FS
    2641 001WD 11 A1 E
    Low DP Transducer, Model 264, 0 to 1wc, 4 to 20mA, Conduit, +-0.4% FS
    2641 001WD 11 T1 C
    Low DP Transducer, Model 264, 0 to 1wc, 4 to 20mA, Terminal Strip, +-1% FS
    2641 001WD 11 T1 C
    Low DP Transducer, Model 264, 0 to 1wc, 4 to 20mA, Terminal Strip, +-1% FS
    2641 001WD 11 T1 F
    Low DP Transducer, Model 264, 0 to 1wc, 4 to 20mA, Terminal Strip, +-0.25% FS
    2641 001WD 11 T1 F
    Low DP Transducer, Model 264, 0 to 1wc, 4 to 20mA, Terminal Strip, +-0.25% FS
    2641 005WB 11 T1 C
    Low DP Transducer, Model 264, +-5wc, 4 to 20mA, Terminal Strip, +-1% FS
    2641 005WB 11 T1 C
    Low DP Transducer, Model 264, +-5wc, 4 to 20mA, Terminal Strip, +-1% FS
    2641 005WB 11 T1 F
    Low DP Transducer, Model 264, +-5wc, 4 to 20mA, Terminal Strip, +-0.25% FS
    2641 005WB 11 T1 F
    Low DP Transducer, Model 264, +-5wc, 4 to 20mA, Terminal Strip, +-0.25% FS
    2641 005WD 11 T1 C
    Low DP Transducer, Model 264, 0 to 5wc, 4 to 20mA, Terminal Strip, +-1% FS
    2641 005WD 11 T1 C
    Low DP Transducer, Model 264, 0 to 5wc, 4 to 20mA, Terminal Strip, +-1% FS
    2641 005WD 11 T1 F
    Low DP Transducer, Model 264, 0 to 5wc, 4 to 20mA, Terminal Strip, +-0.25% FS
    2641 005WD 11 T1 F
    Low DP Transducer, Model 264, 0 to 5wc, 4 to 20mA, Terminal Strip, +-0.25% FS
    2641 0R1WB 11 T1 F
    Low DP Transducer, Model 264, +-0.1wc, 4 to 20mA, Terminal Strip, +-0.25% FS
    2641 0R1WB 11 T1 F
    Low DP Transducer, Model 264, +-0.1wc, 4 to 20mA, Terminal Strip, +-0.25% FS