Fire Alarm Control Panels

Flex 505 Fire Alarm Control Panel

The Flex 505 is a five zone fire alarm control panel (FACP). This combination control and digital communicator panel provides reliable fire signaling protection for medium sized commercial, industrial and institutional buildings.

The Flex 505 is a five zone fire alarm control panel (FACP) . This combination control and digital communicator panel provides reliable fire signaling protection for medium-sized commercial, industrial and institutional buildings.

Initiating Device Circuits (IDCs) for Flex Series panels are programmable and operate in Class B (Style B). Each panel is compatible with conventional input devices such as two-wire smoke detectors, four-wire smoke detectors, pull stations, water flow devices, tamper switches and other normally-open contact devices. This includes System Sensor i3™ Series microprocessor-based detectors with advanced features, like drift compensation, maintenance alert and freeze warning.

Features & Benefits:
  • Style B (Class B) initiating device circuits (IDCs) - five programmable IDCs
  • Built-in digital alarm communicator/transmitter (DACT)
  • Four Style Y (Class B) notification appliance circuits (NACs) programmable for: ADA compliant strobe synchronization, Selective silence (horn/strobe mute), Temporal or steady signal, silence able or non-silence able, Auto-silence and silence inhibit
  • Three programmable Form-C relays
  • 24 VDC special application power outputs (resettable and non-resettable)
  • Optional Class A converter module for NACs and IDCs (model CAC-5X)
  • Optional transmitter module for municipal box service and reverse polarity (model 4XTMF)
  • Completely field programmable at keypad. Needs no special software or extra equipment; two password protected programming levels
  • 80-character, backlit, high-angle, LCD display
Certifications:
  • UL: S1869
  • FM Approved:
  • MEA Approved:
  • CSFM: 7300-1703: 0166
  • The VMC Group (Seismic): VMA-45894-02C (Revision 1)
  • ISO 9001 Certification

Others

  • Operating Voltage
    • 120 voltage alternating current
  • Maximum Battery Capacity
    • 26
  • Standby Current
    • 2 milliampere
  • Output Current
    • 15 milliampere
  • Loop Capacity
    • 5
  • Main Frequency
    • 60hertz
  • Conventional / Addressable
    • Conventional
  • For Use With
    • Four-Wire Smoke Detectors
    • Backbox
    • Pull Stations
    • Other Normally-Open Contact Devices
    • Two-Wire Smoke Detectors
    • Tamper Switches
    • Water-Flow Devices

Others

  • Operating Voltage
    • 120 voltage alternating current
  • Maximum Battery Capacity
    • 26
  • Standby Current
    • 2 milliampere
  • Output Current
    • 15 milliampere
  • Loop Capacity
    • 5
  • Main Frequency
    • 60hertz
  • Conventional / Addressable
    • Conventional
  • For Use With
    • Four-Wire Smoke Detectors
    • Backbox
    • Pull Stations
    • Other Normally-Open Contact Devices
    • Two-Wire Smoke Detectors
    • Tamper Switches
    • Water-Flow Devices
  • Loop Capacity : 5
  • Main Frequency : 60hertz
  • Conventional / Addressable : Conventional
  • For Use With : Four-Wire Smoke Detectors|Backbox|Pull Stations|Other Normally-Open Contact Devices|Two-Wire Smoke Detectors|Tamper Switches|Water-Flow Devices
  • Operating Voltage : 120 voltage alternating current
  • Maximum Battery Capacity : 26
  • Standby Current : 2 milliampere
  • Output Current : 15 milliampere
Sort
Others
Document Title
File Size
Date Added
Asset Language
Content Type
Manuals and Guides
Document Title
File Size
Date Added
Asset Language
Content Type
Data Sheet
Document Title
File Size
Date Added
Asset Language
Content Type
Document Title
File Size
Date Added
Asset Language
Content Type
Image
SKU
Description
alt
GF505
Flex 505 Conventional FACP, 5 Zone, 120V AC, w/ FLPS-7 Power Supply, Red