    Isolator Module

    Isolator Module by Notifier is used with FireWarden Series panels to protect the system against wire-to-wire short circuits on the SLC loop.

    Overview

    The NOTIFIER N100-ISO(A) Fault Isolator Module is used with FireWarden Series panels to protect the system against wire-to-wire short circuits on the SLC loop. The N100-ISO(A) should be placed between each device on the SLC loop to isolate a short-circuit problem between the modules. It is required for true Style 7 operation so that other devices can continue to operate normally in the event of a short-circuit on the SLC.

    Features & Benefits:
    • Powered by SLC loop directly, no external power required
    • Mounts in standard junction boxes
    • Integral LED blinks to indicate normal condition. Illuminates steady when short circuit condition is detected
    • High noise (EMF/RFI) immunity.
    Certifications:
    • UL Listed: S635
    • CSFM: 7300-0028:0238
    • MEA: 427-91-E Vol. 9
    • FM Approved.
    Specifications

    Others

    • Product Type
      • Fault Isolator Module
    • Brand
      • NOTIFIER
      • System Sensor

    Others

    • Product Type
      • Fault Isolator Module
    • Brand
      • NOTIFIER
      • System Sensor
    • Product Type : Fault Isolator Module
    • Brand : NOTIFIER|System Sensor
    Others
    Name
    Description
    File Size
    Date
    Size
    N100-ISO Installation Manual
    application/pdf 614.7 KB
    9/16/2024
    614.7 KB
    Data Sheet
    Name
    Description
    File Size
    Date
    Size
    N100-ISO(A) Data Sheet
    application/pdf 120.01 KB
    1/5/2012
    120.01 KB
    Name
    Description
    File Size
    Date
    Size
    N100-ISO(A) Data Sheet
    application/pdf 120.01 KB
    1/5/2012
    120.01 KB
    N100-ISO Installation Manual
    application/pdf 614.7 KB
    9/16/2024
    614.7 KB
    Name
    Description
    File Size
    Date
    Size
    N100-ISO Installation Manual
    614.7 KB
    9/16/2024
    N100-ISO(A) Data Sheet
    120.01 KB
    1/5/2012
    Product Number
    Part Number
    Compare
    Description
    Leaf Category
    Thumbnail
    Add to list
    N100-ISO
    SLC LOOP ISOLATOR MODULE; ISOLATES AGAINST SHORT CIRCUITS ON THE SLC.
    https://honeywell.scene7.com/is/image/Honeywell65/hbt-fire-n100-iso-isolator-module-not-hw
    N100-ISO
    SLC LOOP ISOLATOR MODULE; ISOLATES AGAINST SHORT CIRCUITS ON THE SLC.
    https://honeywell.scene7.com/is/image/Honeywell65/hbt-fire-n100-iso-isolator-module-not-hw