Control Modules
Eight balanced input module
Input module is suitable for controlling detection systems with conventional lines and can be used in systems with already existing detection lines for controlling automatic fire extinguishing systems with double enable logic.
Eight balanced input module for conventional safety related sensors. All channels can be reset individually and are tested every 30 seconds during operation. This module is suitable for controlling detection systems with conventional lines and can be used in systems with already existing detection lines for controlling automatic fire extinguishing systems with double enable logic or intrinsically safe systems.
Features & Benefits:- It is used for controlling all the devices typical of fire extinguishing systems
- 2 programmable Alarm thresholds on 255 levels
- Channel tested every 30 seconds during operation
Others
- Maximum Operating Ambient Temperature
- 50 degree Celsius
- Maximum Operating Humidity
- 95 Non-Condensing percentage relative humidity
- Normal Input Current
- 115 milliampere
- Minimum Operating Ambient Temperature
- -5 degree Celsius
- Alarm Current
- 0.048 ampere
- Maximum Output Current
- 4 - 20 milliampere
- Maximum Standby Current
- 14 milliampere
- Brand
- Honeywell Industrial Fire
- Maximum IDC Wiring Resistance
- 5600 Ω
- Number of Inputs
- 8
- Type
- Conventional Detection Card
Others
- Maximum Operating Ambient Temperature
- 50 degree Celsius
- Maximum Operating Humidity
- 95 Non-Condensing percentage relative humidity
- Normal Input Current
- 115 milliampere
- Minimum Operating Ambient Temperature
- -5 degree Celsius
- Alarm Current
- 0.048 ampere
- Maximum Output Current
- 4 - 20 milliampere
- Maximum Standby Current
- 14 milliampere
- Brand
- Honeywell Industrial Fire
- Maximum IDC Wiring Resistance
- 5600 Ω
- Number of Inputs
- 8
- Type
- Conventional Detection Card
- Brand : Honeywell Industrial Fire
- Maximum IDC Wiring Resistance : 5600 Ω
- Number of Inputs : 8
- Type : Conventional Detection Card
- Maximum Operating Ambient Temperature : 50 degree Celsius
- Maximum Operating Humidity : 95 Non-Condensing percentage relative humidity
- Normal Input Current : 115 milliampere
- Minimum Operating Ambient Temperature : -5 degree Celsius
- Alarm Current : 0.048 ampere
- Maximum Output Current : 4 - 20 milliampere
- Maximum Standby Current : 14 milliampere
Image
SKU
Description
H-F3002
Eight balanced input module, 22-29V DC, 14mA, -5-50 C Operating temperature, Redundancy not possible
H-F3002-UL
Eight balanced input module, 22-29V DC, 14mA, -5-50 C Operating temperature, Redundancy possible
H-F3002-2
Eight balanced input module, 22-29V DC, 14mA, -5-50 C Operating temperature, UL version has a case with 6 racks