Fire Alarm Control Panels

Conventional Fire Alarm Control Panel

The Flex 505 is a five zone fire alarm control panel (FACP). The Flex combination control and digital communicator panel provides reliable fire signaling protection for medium sized commercial, industrial and institutional buildings.

The Flex 505 is a five zone fire alarm control panel (FACP). The Flex combination control and digital communicator panel provides reliable fire signalling protection for medium sized commercial, industrial and institutional buildings.

Initiating Device Circuits (IDCs) for Flex Series panels are programmable and operate in Class B (Style B). Each panel is compatible with conventional input devices such as two-wire smoke detectors, four-wire smoke detectors, pull stations, water flow devices, tamper switches and other normally-open contact devices. This includes System Sensor i3™ Series microprocessor-based detectors with advanced features, like drift compensation, maintenance alert and freeze warning. (See the Gamewell FCI Device Compatibility Document, P/N 52195, for a listing of compatible devices). Outputs include four Notification Appliance Circuits (NACs), three programmable Form-C relays (factory pre-set for Alarm, Trouble and Supervisory), and resettable and non-resettable power (24 V DC) for special applications.

Features & Benefits:
  • 24 V DC special application power outputs (resettable and nonresettable)
  • Optional Class A converter module for NACs and IDCs (model CAC-5X)
  • Optional transmitter module for municipal box service and reverse polarity (model 4XTMF)
  • Completely field programmable at keypad
Certifications:
  • UL 864 9th Edition
  • ISO 9001 Certified

Others

  • Operating Voltage
    • 120 voltage alternating current
  • Maximum Battery Capacity
    • 26
  • Standby Current
    • 2 milliampere
  • Output Current
    • 15 milliampere
  • Loop Capacity
    • 5
  • Main Frequency
    • 60hertz
  • Brand
    • Gamewell-FCI
  • For Use With
    • Four-Wire Smoke Detectors
    • Backbox
    • Pull Stations
    • Other Normally-Open Contact Devices
    • Two-Wire Smoke Detectors
    • Tamper Switches
    • Water-Flow Devices

Others

  • Operating Voltage
    • 120 voltage alternating current
  • Maximum Battery Capacity
    • 26
  • Standby Current
    • 2 milliampere
  • Output Current
    • 15 milliampere
  • Loop Capacity
    • 5
  • Main Frequency
    • 60hertz
  • Brand
    • Gamewell-FCI
  • For Use With
    • Four-Wire Smoke Detectors
    • Backbox
    • Pull Stations
    • Other Normally-Open Contact Devices
    • Two-Wire Smoke Detectors
    • Tamper Switches
    • Water-Flow Devices
  • Loop Capacity : 5
  • Main Frequency : 60hertz
  • Brand : Gamewell-FCI
  • For Use With : Four-Wire Smoke Detectors|Backbox|Pull Stations|Other Normally-Open Contact Devices|Two-Wire Smoke Detectors|Tamper Switches|Water-Flow Devices
  • Operating Voltage : 120 voltage alternating current
  • Maximum Battery Capacity : 26
  • Standby Current : 2 milliampere
  • Output Current : 15 milliampere
Data Sheet
Name
Description
File Size
Date
Size
Flex GF505W and GF510 Five and Ten Zone FACPs Data Sheet
application/pdf 69.24 KB
5/18/2022
69.24 KB
Manuals and Guides
Name
Description
File Size
Date
Size
GF505 and GF510 Series Operating Instructions
application/pdf 106.08 KB
5/18/2022
106.08 KB
Others
Name
Description
File Size
Date
Size
Seismic Design Of Nonstructural Components And Systems
application/pdf 366.36 KB
5/18/2022
366.36 KB
Name
Description
File Size
Date
Size
Flex GF505W and GF510 Five and Ten Zone FACPs Data Sheet
69.24 KB
5/18/2022
69.24 KB
Seismic Design Of Nonstructural Components And Systems
366.36 KB
5/18/2022
366.36 KB
GF505 and GF510 Series Operating Instructions
106.08 KB
5/18/2022
106.08 KB