/content/hbtbt/us/en/search-results.html
    false
    false
    false

    Smoke Detectors

    Fire-Lite SWIFT® Wireless Photoelectric Smoke Detector

    W-SD355 addressable, wireless photoelectric detectors use a state of the art photoelectric sensing chamber to provide open area protection.

    Overview

    FireLite Alarms’ SWIFT® wireless detectors are intelligent (addressable) detectors which provide secure, reliable communication to the Fire Alarm Control Panel (FACP) across a Class A mesh network. Wireless detectors create an opportunity for applications where it is costly (concrete walls/ceilings, buried wires), obtrusive (surface mount conduit), or possibly dangerous (asbestos) to use traditional wired devices. In addition, both wired and wireless devices can be present on the same FACP providing an integrated wired-wireless solution for increased installation potential.

    The SWIFT detection line includes a photoelectric, photo/thermal, standard fixed heat, and rate-of-rise heat detectors. The photoelectric detectors transmit a digital representation of smoke density through a wireless mesh to a gateway and on to a FACP. The photo/thermal detectors combine a photoelectric chamber and a 135°F fixed temperature heat detector. The fixed heat detector and rate-ofrise detectors utilize sensors designed for open area protection with 50 foot spacing capability as approved by UL 521.

    All sensors offer addressable code wheels and two LEDs. The LEDs are controlled by the panels. Operation modes include red, green, and amber colors with various solid or blink patterns. The mesh network within the SWIFT system creates a child-parent relationship between the devices so that each device has two parents providing a second path for communications on every device. If one device can no longer operate for any reason, the rest of the devices can still communicate with each other, directly or through one or more intermediate devices.

    The SWIFT system also engages frequency hopping to prevent system interference whether intentional or accidental.

    The devices communicate across the mesh network through a gateway to the FACP. The FACP views the SWIFT wireless device and another addressable device on the system providing similar detection functions and outputs as a wired counterpart. In addition, both wired and wireless devices can be present on the same FACP to meet the needs of a given application. A SWIFT wireless system can use any combination of modules, smoke and heat detectors, pullstations, and A/V bases.

    Features & Benefits:
    • Wireless installation
    • Class A mesh network
    • Addressable code wheels
    • Commercial applications
    • UL 268 listed
    • Frequency hopping
    • Bi-directional communications
    Certifications:
    • UL Listed: S1059 & S2517
    • CSFM: 7272-0075:0230, 7254-0075:0229
    • FM Approved
    • FCC ID: AUBWFSSD
    Specifications

    Others

    • Brand
      • Fire-Lite
      • SWIFT

    Others

    • Brand
      • Fire-Lite
      • SWIFT
    • Brand : Fire-Lite|SWIFT
    Others
    Name
    Description
    File Size
    Date
    Size
    W-SD355 Drawing
    image/vnd.dwg 176.63 KB
    10/3/2024
    176.63 KB
    RF Scan Reference Guide
    application/pdf 1.27 MB
    10/3/2024
    1.27 MB
    W-SD355 and W-SD355T analog addressable photoelectric smoke detectors Listing
    application/pdf 171.38 KB
    10/3/2024
    171.38 KB
    SWIFT Drawing
    application/zip 1.87 MB
    4/28/2023
    1.87 MB
    SWIFT_FAQ FAQ
    application/pdf 142.2 KB
    3/1/2017
    142.2 KB
    Link Test Reference Guide
    application/pdf 1.03 MB
    10/3/2024
    1.03 MB
    Mesh Network Reference Guide
    application/pdf 2.07 MB
    10/3/2024
    2.07 MB
    Sales Sheet
    Name
    Description
    File Size
    Date
    Size
    SWIFT Wireless Sell Sheet
    application/pdf 500.37 KB
    10/3/2024
    500.37 KB
    SWIFT Wireless Sell Sheet
    application/pdf 1.46 MB
    10/3/2024
    1.46 MB
    Installation Instructions
    Name
    Description
    File Size
    Date
    Size
    W-SD355-T Wireless Intelligent Photoelectric Smoke Sensor Installation Document
    application/pdf 379.3 KB
    10/3/2024
    379.3 KB
    SD355, SD355T and AD355 Addressable Photoelectric Smoke Sensors Installation Document
    application/pdf 651.48 KB
    10/3/2024
    651.48 KB
    System Sensor Base-Detector Compatibility Chart
    application/pdf 53.71 KB
    5/8/2023
    53.71 KB
    Manuals and Guides
    Name
    Description
    File Size
    Date
    Size
    Cybersecurity Manual
    application/pdf 340.86 KB
    12/14/2020
    340.86 KB
    Data Sheet
    Name
    Description
    File Size
    Date
    Size
    SWIFT Wireless Modules Data Sheet
    application/pdf 224.36 KB
    8/16/2022
    224.36 KB
    SWIFT Sistema de puerta de enlace inalambrica Data Sheet
    application/pdf 501.93 KB
    11/14/2014
    501.93 KB
    SWIFT Wireless Modules Data Sheet
    application/pdf 224.36 KB
    8/16/2022
    224.36 KB
    SWIFT Wireless Detectors Data Sheet
    application/pdf 161.45 KB
    8/16/2022
    161.45 KB
    SWIFT Detectores inalambricos inteligentes Data Sheet
    application/pdf 109.92 KB
    4/19/2023
    109.92 KB
    SWIFT Wireless Gateway System Data Sheet
    application/pdf 176.42 KB
    8/16/2022
    176.42 KB
    SWIFT Wireless Gateway Data Sheet
    application/pdf 176.42 KB
    8/16/2022
    176.42 KB
    W-BG12LX(SP) Data Sheet
    application/pdf 261.84 KB
    8/16/2022
    261.84 KB
    Name
    Description
    File Size
    Date
    Size
    SWIFT Wireless Modules Data Sheet
    application/pdf 224.36 KB
    8/16/2022
    224.36 KB
    W-SD355 Drawing
    image/vnd.dwg 176.63 KB
    10/3/2024
    176.63 KB
    RF Scan Reference Guide
    application/pdf 1.27 MB
    10/3/2024
    1.27 MB
    W-SD355-T Wireless Intelligent Photoelectric Smoke Sensor Installation Document
    application/pdf 379.3 KB
    10/3/2024
    379.3 KB
    SWIFT Wireless Sell Sheet
    application/pdf 500.37 KB
    10/3/2024
    500.37 KB
    SD355, SD355T and AD355 Addressable Photoelectric Smoke Sensors Installation Document
    application/pdf 651.48 KB
    10/3/2024
    651.48 KB
    W-SD355 and W-SD355T analog addressable photoelectric smoke detectors Listing
    application/pdf 171.38 KB
    10/3/2024
    171.38 KB
    SWIFT Drawing
    application/zip 1.87 MB
    4/28/2023
    1.87 MB
    SWIFT Sistema de puerta de enlace inalambrica Data Sheet
    application/pdf 501.93 KB
    11/14/2014
    501.93 KB
    SWIFT Wireless Modules Data Sheet
    application/pdf 224.36 KB
    8/16/2022
    224.36 KB
    SWIFT Wireless Detectors Data Sheet
    application/pdf 161.45 KB
    8/16/2022
    161.45 KB
    SWIFT Detectores inalambricos inteligentes Data Sheet
    application/pdf 109.92 KB
    4/19/2023
    109.92 KB
    SWIFT Wireless Gateway System Data Sheet
    application/pdf 176.42 KB
    8/16/2022
    176.42 KB
    SWIFT_FAQ FAQ
    application/pdf 142.2 KB
    3/1/2017
    142.2 KB
    System Sensor Base-Detector Compatibility Chart
    application/pdf 53.71 KB
    5/8/2023
    53.71 KB
    Link Test Reference Guide
    application/pdf 1.03 MB
    10/3/2024
    1.03 MB
    Cybersecurity Manual
    application/pdf 340.86 KB
    12/14/2020
    340.86 KB
    SWIFT Wireless Gateway Data Sheet
    application/pdf 176.42 KB
    8/16/2022
    176.42 KB
    W-BG12LX(SP) Data Sheet
    application/pdf 261.84 KB
    8/16/2022
    261.84 KB
    Mesh Network Reference Guide
    application/pdf 2.07 MB
    10/3/2024
    2.07 MB
    SWIFT Wireless Sell Sheet
    application/pdf 1.46 MB
    10/3/2024
    1.46 MB
    Name
    Description
    File Size
    Date
    Size
    W-SD355 Drawing
    176.63 KB
    10/3/2024
    RF Scan Reference Guide
    1.27 MB
    10/3/2024
    W-SD355 and W-SD355T analog addressable photoelectric smoke detectors Listing
    171.38 KB
    10/3/2024
    SWIFT Drawing
    1.87 MB
    4/28/2023
    SWIFT_FAQ FAQ
    142.2 KB
    3/1/2017
    Link Test Reference Guide
    1.03 MB
    10/3/2024
    Mesh Network Reference Guide
    2.07 MB
    10/3/2024
    SWIFT Wireless Sell Sheet
    500.37 KB
    10/3/2024
    SWIFT Wireless Sell Sheet
    1.46 MB
    10/3/2024
    W-SD355-T Wireless Intelligent Photoelectric Smoke Sensor Installation Document
    379.3 KB
    10/3/2024
    SD355, SD355T and AD355 Addressable Photoelectric Smoke Sensors Installation Document
    651.48 KB
    10/3/2024
    System Sensor Base-Detector Compatibility Chart
    53.71 KB
    5/8/2023
    Cybersecurity Manual
    340.86 KB
    12/14/2020
    SWIFT Wireless Modules Data Sheet
    224.36 KB
    8/16/2022
    SWIFT Sistema de puerta de enlace inalambrica Data Sheet
    501.93 KB
    11/14/2014
    SWIFT Wireless Modules Data Sheet
    224.36 KB
    8/16/2022
    SWIFT Wireless Detectors Data Sheet
    161.45 KB
    8/16/2022
    SWIFT Detectores inalambricos inteligentes Data Sheet
    109.92 KB
    4/19/2023
    SWIFT Wireless Gateway System Data Sheet
    176.42 KB
    8/16/2022
    SWIFT Wireless Gateway Data Sheet
    176.42 KB
    8/16/2022
    W-BG12LX(SP) Data Sheet
    261.84 KB
    8/16/2022
    Product Number
    Part Number
    Compare
    Description
    Leaf Category
    Thumbnail
    Add to list
    W-SD355
    Intelligent Wireless Photo Detector, B501W Base, Requires (4) CR-123A Batteri
    https://honeywell.scene7.com/is/image/Honeywell65/HBT-Fire-W-SD355-CEILING-HiRes
    W-SD355
    Intelligent Wireless Photo Detector, B501W Base, Requires (4) CR-123A Batteri
    https://honeywell.scene7.com/is/image/Honeywell65/HBT-Fire-W-SD355-CEILING-HiRes