https://buildings.honeywell.com/us/en/search-results.html

Smoke Detectors

Photoelectric Smoke Detector

Photoelectric Smoke Detector is a low-profile intelligent photoelectric sensor and remote test capable is use with DNR/DNRW.

Photoelectric Smoke Detector is a low-profile intelligent photoelectric sensor and remote test capable is use with DNR/DNRW. NP-200 Series intelligent plug-in smoke detectors are designed for both performance and aesthetics and are direct replacements for the NP-100 Series. The NP-200 Series also offers 135°F (57°C) fixed temperature thermal sensing on the NP-200T and a remote test capable detector on the NP-200R for use with DNR (A)/DNRW duct smoke detector housings.

Features & Benefits:
  • Two-wire SLC loop connection
  • Stable communication technique with noise immunity
  • Sleek, low-profile and Stylish design
  • Unique single-source design to respond quickly and dependably to a broad range of fires
  • Integral communications and built-in device-type identification
  • Built-in tamper resistant feature
  • Remote test feature from the panel
  • Built-in functional test switch activated by external magnet
  • Removable cover and insect-resistant screen for simple field cleaning
  • Expanded colour options
Certifications:
  • UL/ULC Listing: S1115
  • FM Approved
  • CSFM: 7272-0028:0503

Others

  • Maximum Standby Current
    • 200 µA @ 24 voltage direct current
  • Maximum Operating Humidity
    • 93 Percentage
  • Maximum Operating Voltage
    • 15 - 32 Peak voltage direct current
  • Minimum Operating Humidity
    • 10 Percentage
  • Material
    • Plastic
  • Wiring Type
    • 2-Wire
  • Detection Sensor Type
    • Photoelectric
  • Brand
    • System Sensor
  • Sensitivity
    • 0.5 - 4Percentage
    • 0.5 - 3.5Percentage
  • Conventional or Addressable
    • Addressable

Others

  • Maximum Standby Current
    • 200 µA @ 24 voltage direct current
  • Maximum Operating Humidity
    • 93 Percentage
  • Maximum Operating Voltage
    • 15 - 32 Peak voltage direct current
  • Minimum Operating Humidity
    • 10 Percentage
  • Material
    • Plastic
  • Wiring Type
    • 2-Wire
  • Detection Sensor Type
    • Photoelectric
  • Brand
    • System Sensor
  • Sensitivity
    • 0.5 - 4Percentage
    • 0.5 - 3.5Percentage
  • Conventional or Addressable
    • Addressable
  • Material : Plastic
  • Wiring Type : 2-Wire
  • Detection Sensor Type : Photoelectric
  • Brand : System Sensor
  • Sensitivity : 0.5 - 4Percentage|0.5 - 3.5Percentage
  • Conventional or Addressable : Addressable
  • Maximum Standby Current : 200 µA @ 24 voltage direct current
  • Maximum Operating Humidity : 93 Percentage
  • Maximum Operating Voltage : 15 - 32 Peak voltage direct current
  • Minimum Operating Humidity : 10 Percentage
Document Title
File Size
Date Added
Image
SKU
Description
alt
NP-200R-IV
Photoelectric Smoke Detector: 15-32V DC: 4.5 mA max: White
alt
NP-200R
REMOTE TEST CAPABLE INTELLIGENT ADDRESSABLE PHOTO DETECTOR; FOR USE WITH DNR(W) DUCT DETECTOR HOUSING; WHITE